Pull-out strength of the glued-in joint in laminated bamboo structure

被引:5
|
作者
Feng, Yan [1 ,2 ]
Xu, Ming [1 ,2 ]
Xu, Yao [3 ]
Tu, Liuhui [1 ,2 ]
Chen, Sunyue [1 ,2 ]
机构
[1] Southeast Univ, Minist Educ, Key Lab RC&PC Struct, Nanjing 210096, Peoples R China
[2] Southeast Univ, Sch Civil Engn, Nanjing 210096, Peoples R China
[3] Guangdong Architectural Design & Res Inst Co Ltd, Guangzhou 510000, Peoples R China
关键词
Glued-in joint; Laminated bamboo; Load-slip relationship; Design recommendations; TIMBER STRUCTURES; RODS; BEHAVIOR; CONNECTIONS; PARALLEL; ADHESIVE;
D O I
10.1016/j.istruc.2023.03.021
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The glued-in joint has proven its reliability, practicality, and flexibility in timber and concrete structures since first proposed. To study the pull-out strength of the glued-in joint in laminated bamboo structure, 27 specimens in pull-pull configuration were conducted. The influence of parameters, i.e., edge distance of the rebar, glue thickness, rebar diameter, anchorage length, were all tested by monotonic pull-out tests parallel to the grain. Three failure modes were characterized by the experimental results, referring to the splitting of laminated bamboo block, pull-out, and failure of rebar after yielding. Concluded from the experimental results, it is found that the first failure mode could be avoided by restricting the edge distance of the rebar in a reasonable range. The initial stiffness and load-carrying capacity of the latter two failure modes were recognized to be estimated in terms of the rebar diameter and anchorage length. Based on the existed theory, the feasibility of the traditional method was discussed and a simplified formula was developed based on the experimental results and theoretical derivation, which showed that the deviation is less than 6%. Finally, recommendations were made for the design of glued-in joint in the laminated bamboo structure.
引用
收藏
页码:1052 / 1060
页数:9
相关论文
共 50 条
  • [21] Experimental investigation of the axial strength of glued-in rods in cross laminated timber
    Azinovic, Boris
    Serrano, Erik
    Kramar, Miha
    Pazlar, Tomaz
    MATERIALS AND STRUCTURES, 2018, 51 (06)
  • [22] Correction to: Experimental investigation of the axial strength of glued-in rods in cross laminated timber
    Boris Azinović
    Erik Serrano
    Miha Kramar
    Tomaž Pazlar
    Materials and Structures, 2019, 52
  • [23] PULL-OUT STRENGTH OF CASPAR CERVICAL SCREWS
    MAIMAN, DJ
    PINTAR, FA
    YOGANANDAN, N
    REINARTZ, J
    TOSELLI, R
    WOODWARD, E
    HAID, R
    NEUROSURGERY, 1992, 31 (06) : 1097 - 1101
  • [24] PULL-OUT STRENGTH OF 5 SUTURE ANCHORS
    CARPENTER, JE
    FISH, DN
    HUSTON, LJ
    GOLDSTEIN, SA
    ARTHROSCOPY, 1993, 9 (01): : 109 - 113
  • [25] MODEL FOR PULL-OUT STRENGTH OF ANCHORS IN CONCRETE
    PEIER, WH
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1983, 109 (05): : 1155 - 1173
  • [26] Dowel-Bearing Strength Behavior of Glued Laminated Guadua Bamboo
    Ramirez, Fernando
    Correal, Juan F.
    Yamin, Luis E.
    Atoche, Juan C.
    Piscal, Carlos M.
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2012, 24 (11) : 1378 - 1387
  • [27] Strength properties of glued laminated bamboo (Gigantochloa scortechinnii) strips for furniture
    Nordin, K
    Wahab, R
    Jamaludin, MA
    Bahari, SA
    Zakaria, MN
    Using Wood Composites as a Tool for Sustainable Forestry, 2005, 163 : 83 - 85
  • [28] PULL-OUT STRENGTH OF CASPAR CERVICAL SCREWS - REPLY
    MAIMAN, DJ
    NEUROSURGERY, 1993, 33 (01) : 172 - 172
  • [29] The Research of Pull-out Method to Inspect Concrete Strength
    Li, Fengquan
    Wang, Chen
    Jiang, Hongbin
    Li, Xueying
    ADVANCES IN BUILDING MATERIALS, PTS 1-3, 2011, 168-170 : 2344 - 2347
  • [30] Pull-Out Strength of Orthodontic Miniscrews in the Temporal Bone
    Menke, Christian
    Kluge, Marcel
    Welke, Bastian
    Lenarz, Thomas
    Majdani, Omid
    S. Rau, Thomas
    JOURNAL OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2024, 53 : 19160216241248669