Characterization of an Inter-digitated Sensor for Non-invasive Blood-glucose Sensing

被引:1
|
作者
Satish [1 ,2 ]
Sen, Kushal [3 ]
机构
[1] Indian Inst Technol, Ctr Biomed Engn, New Delhi, India
[2] CSIR, Natl Phys Lab, LF HF Impedance & DC Metrol, New Delhi, India
[3] Indian Inst Technol, Dept Text & Fibre Engn, New Delhi, India
关键词
Blood glucose; Diabetes; Electromagnetic properties; Fetal-bovine serum; Microwave sensor; Sensitivity factor; HYPOGLYCEMIA; SYSTEM;
D O I
10.1080/03772063.2023.2202638
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A microwave sensor with an inter-digitated structure is proposed to estimate non-invasive blood glucose sensing. The proposed sensor is designed, fabricated and measured for the required specifications. The transmission electromagnetic response is investigated to predict the blood-glucose level. Initially, the effectiveness of the fabricated sensor is demonstrated with the help of controlled experiments, performed in fetal-bovine serum sample solutions. A novel multi-parameter-based sensitivity factor is determined to estimate the blood glucose level. The proposed work showed that a multi-parameter approach may be effectively utilized to determine the blood-glucose level non-invasively.
引用
收藏
页码:4203 / 4208
页数:6
相关论文
共 50 条
  • [21] Non-invasive Estimation of Blood Glucose
    Sidley, Matthew
    Venkataraman, Jayanti
    2013 IEEE APPLIED ELECTROMAGNETICS CONFERENCE (AEMC), 2013,
  • [22] Non-invasive Blood-Glucose Estimation Using Smartphone PPG Signals and Subspace KNN Classifier
    Zhang, Yuwei
    Zhang, Yuan
    Siddiqui, Sarah Ali
    Kos, Anton
    ELEKTROTEHNISKI VESTNIK, 2019, 86 (1-2): : 68 - 74
  • [23] Non-invasive Blood-Glucose Estimation Using Smartphone PPG Signals and Subspace KNN Classifier
    Zhang, Yuwei
    Zhang, Yuan
    Siddiqui, Sarah Ali
    Kos, Anton
    Elektrotehniski Vestnik/Electrotechnical Review, 2019, 86 (01): : 68 - 74
  • [24] Truly non-invasive glucose optical sensor
    Garcia, Marisol
    Perego, Celine
    Hernandez, Florencio E.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 231
  • [25] Evaluation of a guideless non-invasive glucose sensor
    Mattu, Mutua
    Makarawicz, Marcy R.
    Blank, Thomas B.
    Lorenz, Alex D.
    Monfre, Stephen L.
    DIABETES, 2008, 57 : A117 - A117
  • [26] Influence of cholesterol on non-invasive blood glucose sensing studied with NIR spectroscopy
    Jiang, Jingying
    Zhang, Lingling
    Gong, Qiliang
    Xu, Kexin
    DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS VIII, 2011, 7898
  • [27] Discussion on the validity of NIR spectral data in non-invasive blood glucose sensing
    Zhang, Wanjie
    Liu, Rong
    Zhang, Wen
    Jia, Hao
    Xu, Kexin
    BIOMEDICAL OPTICS EXPRESS, 2013, 4 (06): : 789 - 802
  • [28] BLOOD GLUCOSE SENSING THROUGH SKIN BY NON-INVASIVE FINGER TOUCH METER
    Kakkar, T.
    Richards, B.
    Ajjan, R.
    Saha, S.
    Grant, P.
    Jose, G.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2016, 18 : A40 - A40
  • [29] Non-invasive determination of blood glucose level using narrowband microwave sensor
    Deshmukh, Vidya Vijay
    Chorage, Suvarna Sandip
    JOURNAL OF AMBIENT INTELLIGENCE AND HUMANIZED COMPUTING, 2021,
  • [30] Simulation on how to customize glucose adjustment method for non-invasive blood glucose sensing by NIRS
    Min, Xiaolin
    Jiang, Jingying
    Zou, Da
    Liu, Rong
    Xu, Kexin
    DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS IX, 2013, 8580