Pediatric reference interval verification for 17 specialized immunoassays and cancer markers on the Abbott Alinity i system in the CALIPER cohort of healthy children and adolescents

被引:2
|
作者
Bohn, Mary Kathryn [1 ,2 ,3 ]
Wilson, Siobhan [1 ,2 ,3 ]
Schneider, Randal [4 ]
Massamiri, Youssef [5 ]
Randell, Edward W. [5 ]
Adeli, Khosrow [1 ,2 ,3 ]
机构
[1] Hosp Sick Children, Res Inst, Mol Med, CALIPER Program, 555 Univ Ave, Toronto, ON M5G 1X8, Canada
[2] Hosp Sick Children, Dept Pediat Lab Med, 555 Univ Ave, Toronto, ON M5G 1X8, Canada
[3] Univ Toronto, Dept Lab Med & Pathobiol, Toronto, ON, Canada
[4] Abbott Diagnost, Abbott Pk, IL USA
[5] Eastern Hlth Author, Clin Biochem, St John, NL, Canada
关键词
Abbott Alinity; CALIPER; pediatric reference interval; specialized immunoassay; verification; REFERENCE VALUE DISTRIBUTIONS; STRATIFIED REFERENCE INTERVALS; CLSI-BASED TRANSFERENCE; BIOCHEMICAL MARKERS; COMMUNITY CHILDREN; TUMOR-MARKERS; ENDOCRINE; ASSAYS; ESTABLISHMENT; POPULATION;
D O I
10.1515/cclm-2022-0709
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objectives Clinical laboratory investigation of autoimmune, metabolic, and oncologic disorders in children and adolescents relies on appropriateness of reference intervals (RIs). The Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) previously established comprehensive pediatric RIs for specialized immunoassays on the Abbott ARCHITECT system. Herein, we aim to verify performance on new Alinity i assays by evaluating sera collected from healthy children as per Clinical and Laboratory Standards Institute (CLSI) EP-28A3C guidelines. Methods Precision, linearity, and method comparison experiments were completed for 17 specialized Alinity immunoassays, including cancer antigens, autoimmune peptides, and hormones. Sera collected from healthy children and adolescents (birth-18 years, n=100) were evaluated. CLSI-based verification was completed using previously established CALIPER RIs for ARCHITECT assays as the reference. Results Of 17 specialized immunoassays assays, only anti-cyclic citrullinated peptides (anti-CCP) did not meet acceptable verification criterion (i.e., >= 90% of results within ARCHITECT reference CI). Anti-thyroglobulin, anti-thyroid peroxidase, and carcinoembryonic antigen did not require age-specific consideration beyond one year of age, with 63, 91, and 80% of samples equalling the limit of detection, respectively. Estimates were separated by sex for relevant assays (e.g., sex hormone binding globulin, total and free prostate specific antigen). Conclusions Findings support transferability of pediatric RIs on ARCHITECT system to the Alinity system for 16 specialized immunoassays in the CALIPER cohort and will be a useful resource for pediatric clinical laboratories using Alinity assays. Further work is needed to establish evidence-based interpretative recommendations for anti-CCP and continue to evaluate pediatric RI acceptability for newly available assay technologies.
引用
收藏
页码:123 / 132
页数:10
相关论文
共 26 条
  • [21] Pediatric reference intervals for specialty endocrine and chemistry biomarkers on the Abbott ARCHITECT ci4100 System: A CALIPER study of healthy community children
    Bevilacqua, Victoria
    Chan, Mankhun
    Bustos, Susan
    O'Dwyer, Carol
    Schodin, Beth
    Armbruster, David
    Adeli, Khosrow
    CLINICAL BIOCHEMISTRY, 2014, 47 (12) : 1146 - 1146
  • [22] Pediatric reference intervals for clinical chemistry assays on Siemens ADVIA XPT/1800 and Dimension EXL in the CALIPER cohort of healthy children and adolescents
    Tahmasebi, Houman
    Higgins, Victoria
    Woroch, Amy
    Asgari, Shervin
    Adeli, Khosrow
    CLINICA CHIMICA ACTA, 2019, 490 : 88 - 97
  • [23] Marked Biological Variance in Endocrine and Biochemical Markers in Childhood: Establishment of Pediatric Reference Intervals Using Healthy Community Children from the CALIPER Cohort
    Bailey, Dana
    Colantonio, David
    Kyriakopoulou, Lianna
    Cohen, Ashley H.
    Chan, Man Khun
    Armbruster, David
    Adeli, Khosrow
    CLINICAL CHEMISTRY, 2013, 59 (09) : 1393 - 1405
  • [24] Pediatric reference intervals for endocrine markers in healthy children and adolescents on the Liaison XL (DiaSorin) immunoassay system
    Miller, J. J.
    Bohn, M. K.
    Higgins, V.
    Nichols, M.
    Mohammed-Ali, Z.
    Henderson, T.
    Selvaratnam, R.
    Sepiashvili, L.
    Adeli, K.
    CLINICAL BIOCHEMISTRY, 2023, 120
  • [25] Pediatric ☆reference intervals for random glucose on the Radiometer ABL90 FLEX Plus and Nova Biomedical StatStrip in the CALIPER cohort of healthy children and adolescents
    Bohn, Mary Kathryn
    Earle, Hannah
    Hall, Alexandra
    Henderson, Tina
    Adeli, Khosrow
    CLINICAL BIOCHEMISTRY, 2020, 86 : 72 - 72
  • [26] Pediatric reference intervals for endocrine markers and fertility hormones in healthy children and adolescents on the Siemens Healthineers Atellica immunoassay system
    Bohn, Mary Kathryn
    Horn, Paul
    League, Donna
    Steele, Paul
    Hall, Alexandra
    Adeli, Khosrow
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2021, 59 (08) : 1421 - 1430