Effect of inferior vena cava filter placement position on device complications

被引:7
|
作者
Grubman, Scott [1 ,5 ]
Kostiuk, Valentyna [1 ]
Brahmandam, Anand [2 ]
Tonnessen, Britt [2 ]
Mojibian, Hamid [3 ]
Schneider, Eric [4 ]
Guzman, Raul J. [2 ]
Chaar, Cassius Iyad Ochoa [2 ]
机构
[1] Yale Univ, Dept Surg, Sch Med, New Haven, CT USA
[2] Yale Univ, Div Vasc Surg & Endovasc Therapy, Dept Surg, Sch Med, New Haven, CT USA
[3] Yale Univ, Dept Radiol & Biomed Imaging, Sch Med, New Haven, CT USA
[4] Yale Univ, Ctr Hlth Serv & Outcomes Res, Dept Surg, Sch Med, New Haven, CT USA
[5] Yale Univ, Sch Med, Dept Surg, 333 Cedar St, New Haven, CT 06510 USA
关键词
Inferior vena cava; Postoperative complications; Thrombosis; Venous thromboembolism; RENAL-VEIN INFLOW; UPDATE; CELECT; TRENDS; IMPACT; RATES;
D O I
10.1016/j.jvsv.2023.05.020
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Indwelling inferior vena cava (IVC) filters can cause complications, including penetration into surrounding structures, migration, and thrombosis of the vena cava. Computational fluid dynamics suggests juxtarenal placement of IVC filters decreases the risk of thrombosis; however, this has not been explored clinically. The present study examines the effect of filter placement position on long-term device complications with an emphasis on IVC thrombosis. We hypothesized that IVC filters placed further caudal to the renal veins were more likely to develop long-term thrombosis.Methods: A retrospective review of the medical records of patients receiving IVC filters at a single tertiary center between 2008 and 2016 was performed. Patients missing follow-up or procedural imaging data were excluded. The placement procedure venograms were reviewed, and the distance from the filter apex to the more inferior renal vein was measured using reported IVC filter lengths for calibration. The patients were divided into three groups according to the tip position relative to the more inferior renal vein: at or superior (group A), 1 to 20 mm inferior (group B), and >20 mm inferior (group C). The patient and procedural characteristics and outcomes were compared between the three groups. The primary end points were IVC thrombosis and device-related mortality.Results: Of 1497 eligible patients, 267 (17.8%) were excluded. The most common placement position was group B (64.0%). The mean age was lowest in group C, followed by groups A and B (age, 59.5 years, 64.6 years, and 62.2 years, respectively; P = .003). No statistically significant differences were found in the distribution of sex or the measured comorbidities. Group C was the most likely to receive jugular access (group C, 71.7%; group A, 48.3%; group B, 62.4%; P < .001) and received more first-generation filters (group C, 58.5%; group A, 46.6%; group B, 52.5%; P = .045). The short-term (<30-day) and long-term (>= 30-day) outcomes, including access site hematoma, deep vein thrombosis, and pulmonary embolism, were uncommon, with no differences between the groups. Cases of symptomatic filter penetration, migration, and fracture were rare (one, one, and three cases, respectively). Although a pattern of increasing thrombosis with more inferior placement was found, the difference between groups was not statistically significant (group A, 1.5%; group B, 1.8%; group C, 2.5%; P = .638). No cases of device-related mortality occurred. All-cause mortality after a mean follow-up of 2.6 +/- 2.3 years was 41.3% and did not vary significantly between the groups (P = .051). Multivariate logistic regression revealed that placement position did not predict for short- or long-term deep vein thrombosis, pulmonary embolism, IVC thrombosis, or all-cause mortality after adjustment for the baseline patient characteristics.Conclusions: IVC filters have low rates of short- and long-term complications, including IVC thrombosis. The placement position did not affect the occurrence of device complications in this study.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] The inferior vena cava filter and complications associated with its use
    Hudak, Marek
    Kosco, Martin
    Dekanova, Lucia
    Pavlikova, Veronika
    Szaboova, Eva
    Rasiova, Maria
    COR ET VASA, 2024, 66 (03) : 335 - 343
  • [22] Back pain as a sign of inferior vena cava filter complications
    Lause, Michael
    Kamboj, Alisha
    Schwieterman, Ryan
    Duggirala, Vijay
    CLEVELAND CLINIC JOURNAL OF MEDICINE, 2018, 85 (11) : 835 - 836
  • [23] Complications during Conversion of VenaTech Inferior Vena Cava Filter
    Roh, Simon
    Laroia, Sandeep
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2017, 28 (02) : 304 - 305
  • [24] Incidence of Inferior Vena Cava Filter Immediate and Late Complications
    Nejim, Besma
    Locham, Satinderjit
    Aridi, Hanaa Dakour
    Gasparis, Antonios
    Malas, Mahmoud B.
    JOURNAL OF VASCULAR SURGERY, 2018, 67 (06) : E160 - E160
  • [25] The Inferior Vena Cava Filter
    Hoffer, Eric K.
    JAMA INTERNAL MEDICINE, 2013, 173 (18) : 1753 - 1754
  • [26] INFERIOR VENA-CAVA FILTER - SEARCH FOR AN IDEAL DEVICE
    YUNE, HY
    RADIOLOGY, 1989, 172 (01) : 15 - 16
  • [27] Inferior Vena Cava Filter (IVCF) Placement in a Community Hospital: Adherence to Guidelines, Retrieval Rates, and Complications
    Haque, Ayesha
    Ul Haque, Basir
    Rado, Thomas A.
    Kasthuri, Saravanan
    Chintapatla, Rangaswamy
    BLOOD, 2016, 128 (22)
  • [28] Incidence and Complications of Accidental Cannulation of Retroperitoneal Veins During Venography for Inferior Vena Cava Filter Placement
    Gill, Gunvir
    Morita, Satoru
    Kitanosono, Takashi
    Fang, Adam
    Lee, David
    Waldman, David
    ANNALS OF VASCULAR SURGERY, 2013, 27 (06) : 767 - 773
  • [29] Effect of scheduling inferior vena cava filter removal during the placement encounter on filter removal rate
    Kallini, Joseph
    Steinberger, Jonathan
    Lipshutz, H. Gabriel
    Friedman, Marc L.
    Van Allan, Richard J.
    JOURNAL OF VASCULAR SURGERY-VENOUS AND LYMPHATIC DISORDERS, 2021, 9 (03) : 691 - 696
  • [30] Efficacy of prophylactic inferior vena cava filter placement in bariatric surgery
    Obeid, Farouck N.
    Bowling, William M.
    Fike, Janet S.
    Durant, Jacob A.
    SURGERY FOR OBESITY AND RELATED DISEASES, 2007, 3 (06) : 606 - 608