Energy storage concentrates on solar air heaters with artificial S-shaped irregularity on the absorber plate

被引:16
|
作者
Shayan, Mostafa Esmaeili [1 ]
Ghasemzadeh, Farzaneh [2 ]
Rouhani, Seyed Hossein [3 ]
机构
[1] Tarbiat Modares Univ, Dept Biosyst Engn, Tehran, Iran
[2] Iran Univ Sci & Technol, Dept Phys, Tehran, Iran
[3] Natl Kaohsiung Univ Sci & Technol, Dept Elect Engn, Kaohsiung, Taiwan
关键词
Heat transfer; Solar air heaters; Artificial roughness; Thermo-hydraulic performance; Nusselt number; THERMAL PERFORMANCE; EXERGY ANALYSIS; V-RIB; EFFICIENCY; FLOW; ROUGHNESS; CHANNEL; FINS;
D O I
10.1016/j.est.2023.109289
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This study utilizes the friction factor as a means to evaluate the impact of the roughness parameter on both heat transfer and pressure drop. This work involves doing an experimental and numerical investigation on the utilization of artificial roughness in solar air heaters situated in outdoor settings. The study examines the effects of using a rectangular S-shaped arrangement of artificial roughness, both in an inline and staggered configuration. The objective of this study is to validate the enhanced thermo-hydraulic performance of solar air heaters using various arrangements of artificial roughness shapes. The parameters considered include the length of the relative roughness (d/H = 1.33), the height of the relative roughness (e/H = 0.271), and the constant distance between S (b/H = 0.667). The Reynolds number is varied within the range of 3000 to 10,000, while the pitch range (p/H) is set to (1.667, 3.33, 5, 6.667) for in-line arrangements and (l/H) is set to (0.8335, 1.666, 2.5, and 3.335) for staggered arrangements. The results show that enhancing heat transfer using an artificial roughness staggered arrangement is the best. The maximum Nusselt number was observed at a dimensionless pitch-to-height ratio of 3.33 for both inline and staggered arrangements, with values of 4.87 and 4.2 times higher than that of the smooth duct, respectively.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Design a new energy absorber longitudinal member and compare with S-shaped design to enhance the energy absorption capability
    Abdulqadir, Samer Fakhri
    ALEXANDRIA ENGINEERING JOURNAL, 2018, 57 (04) : 3405 - 3418
  • [32] Experimental investigation of thermal performance of flat and v-corrugated plate solar air heaters with and without PCM as thermal energy storage
    Kabeel, A. E.
    Khalil, A.
    Shalaby, S. M.
    Zayed, M. E.
    ENERGY CONVERSION AND MANAGEMENT, 2016, 113 : 264 - 272
  • [33] CFD and thermo-hydraulic analysis of multiple arc roughened absorber plate with gaps used in solar air heaters
    Pandey, Navneet Kumar
    Bajpai, V. K.
    Sharma, Abhishek
    Yadav, Sanjay
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2020, 43 (01) : 3275 - 3281
  • [34] Thermohydraulic performance of solar air heater with staggered multiple V-shaped ribs on the absorber plate
    Jin, Dongxu
    Zuo, Jianguo
    Quan, Shenglin
    Xu, Shiming
    Gao, Hao
    ENERGY, 2017, 127 : 68 - 77
  • [35] Energy and exergy analysis of a trapezoidal absorber plate-based solar air collector
    Reddy, Jagannath
    Jagadish
    Negi, Sushant
    Das, Biplab
    Ehyaei, Mehdi Ali
    Assad, Mamdouh El Haj
    ENERGY SCIENCE & ENGINEERING, 2022, 10 (04) : 1067 - 1082
  • [36] Energy, exergy, and enviroeconomic assessment of double and single pass solar air heaters having a new design absorber
    Abo-Elfadl, Saleh
    Yousef, Mohamed S.
    Hassan, Hamdy
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2021, 149 : 451 - 464
  • [37] Performance analysis of parallel flow flat plate solar air heater having arc shaped wire roughened absorber plate
    Yadav, Kapil Dev
    Prasad, Radha Krishna
    RENEWABLE ENERGY FOCUS, 2020, 32 : 23 - 44
  • [38] Performance analysis of parallel flow flat plate solar air heater having arc shaped wire roughened absorber plate
    Yadav, Kapil Dev
    Prasad, Radha Krishna
    Renewable Energy Focus, 2020, 32 : 23 - 44
  • [39] Heat transfer and friction factor correlations for multiple arc shape roughness elements on the absorber plate used in solar air heaters
    Singh, Anil P.
    Varun
    Siddhartha
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2014, 54 : 117 - 126
  • [40] PERFORMANCES OF CHANNEL-TYPE FLAT-PLATE SOLAR-ENERGY AIR-HEATERS
    SOROUR, MM
    MOTTALEB, ZA
    APPLIED ENERGY, 1984, 18 (01) : 1 - 13