Can Non-Contrast 3T MRI scans predict the type of labral procedure in hip arthroscopy?

被引:1
|
作者
Elnahal, Walid A. [1 ,3 ]
Azzopardi, Christine [2 ]
Strambi, Francesco [1 ]
Nandra, Rajpal [1 ]
Botchu, Rajesh [2 ]
Mcbryde, Callum W. [1 ]
Politis, Angelos [1 ]
机构
[1] Royal Orthopaed Hosp, Young Adult Hip Unit, Bristol Rd North, Birmingham B31 2AP, W Midlands, England
[2] Royal Orthopaed Hosp Birmingham, Radiol Dept, Birmingham, W Midlands, England
[3] Cairo Univ, Fac Med, Cairo, Egypt
关键词
Labral tears; Hip arthroscopy; 3T MRI scan hip; REPAIR; LESIONS;
D O I
10.1007/s00590-022-03279-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The study proposed a simple classification system that aimed at predicting the labral procedure during hip arthroscopy using images from unenhanced 3T MRI scans. Patents and methods Forty patients undergoing hip arthroscopy had their MRI scans reviewed pre-operatively by one of two senior radiologists and classified into: type 1: stable labrum with intra-substance degeneration (no labral repair required), type 2: unstable labrum, no intra-substance degeneration (labral repair required), or type 3: unstable labrum with intra-substance degeneration (Labral repair not feasible). Hip arthroscopy is carried out by one of two surgeons and classified accordingly while blinded to the radiologists' assessment. Results The pre-operative radiological classification managed to predict the labral procedure in 29 cases out of 40 (72.5%). The gamma value was 0.83, and the kappa value was 0.46 denoting moderate agreement. The inter-class correlation coefficient was 0.52 indicating moderate reliability. Conclusion The proposed classification showed a moderate agreement between the radiological findings and arthroscopic findings. As we cannot accurately correlate the MRI findings with the type of surgical management, the surgeon should be prepared for all scenarios of labral procedures.
引用
收藏
页码:1291 / 1297
页数:7
相关论文
共 32 条
  • [21] 3T non-injected phase-contrast MRI sequences for the mapping of the external carotid branches: In vivo radio-anatomical pilot study for feasibility analysis
    Bettoni, Jeremie
    Page, Gwenael
    Salsac, Anne-Virginie
    Constans, Jean-Marc
    Testelin, Sylvie
    Devauchelle, Bernard
    Baledent, Olivier
    Dakpe, Stephanie
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2018, 46 (01) : 98 - 106
  • [22] Combination of high-resolution susceptibility-weighted imaging and the apparent diffusion coefficient: added value to brain tumour imaging and clinical feasibility of non-contrast MRI at 3 T
    Park, S. M.
    Kim, H. S.
    Jahng, G-H
    Ryu, C-W
    Kim, S. Y.
    BRITISH JOURNAL OF RADIOLOGY, 2010, 83 (990): : 466 - 475
  • [23] Non-contrast free-breathing 3D cardiovascular magnetic resonance angiography using REACT (relaxation-enhanced angiography without contrast) compared to contrast-enhanced steady-state magnetic resonance angiography in complex pediatric congenital heart disease at 3T
    Alexander Isaak
    Narine Mesropyan
    Christopher Hart
    Shuo Zhang
    Dmitrij Kravchenko
    Christoph Endler
    Christoph Katemann
    Oliver Weber
    Claus C. Pieper
    Daniel Kuetting
    Ulrike Attenberger
    Darius Dabir
    Julian A. Luetkens
    Journal of Cardiovascular Magnetic Resonance, 24
  • [24] Non-contrast free-breathing 3D cardiovascular magnetic resonance angiography using REACT (relaxation-enhanced angiography without contrast) compared to contrast-enhanced steady-state magnetic resonance angiography in complex pediatric congenital heart disease at 3T
    Isaak, Alexander
    Mesropyan, Narine
    Hart, Christopher
    Zhang, Shuo
    Kravchenko, Dmitrij
    Endler, Christoph
    Katemann, Christoph
    Weber, Oliver
    Pieper, Claus C.
    Kuetting, Daniel
    Attenberger, Ulrike
    Dabir, Darius
    Luetkens, Julian A.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2022, 24 (01)
  • [25] The diagnostic performance of non-contrast 3-Tesla magnetic resonance imaging (3-T MRI) versus 1.5-Tesla magnetic resonance arthrography (1.5-T MRA) in femoro-acetabular impingement
    Crespo-Rodriguez, Ana
    De Lucas-Villarrubia, Jose
    Pastrana-Ledesma, Miguel
    Hualde-Juvera, Ana
    Mendez-Alonso, Santiago
    Padron, Mario
    EUROPEAN JOURNAL OF RADIOLOGY, 2017, 88 : 109 - 116
  • [26] Fresh Blood Imaging using variable TR and variable refocusing flip angle for non-contrast peripheral MR angiography at 3T: a 7-Minute iliac to calf station run-offs scan
    Xiangzhi Zhou
    Mitsue Miyazaki
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [27] Aortic annular dimensions by non-contrast MRI using k–t accelerated 3D cine b-SSFP in pre-procedural assessment for transcatheter aortic valve implantation: a technical feasibility study
    Pascale Aouad
    Kelly Brooke Jarvis
    Marcos Ferreira Botelho
    Ali Serhal
    Julie Blaisdell
    Louise Collins
    Shivraman Giri
    Daniel Kim
    Michael Markl
    Mark J. Ricciardi
    Charles J. Davidson
    Jeremy Collins
    James Carr
    The International Journal of Cardiovascular Imaging, 2021, 37 : 651 - 661
  • [28] Aortic annular dimensions by non-contrast MRI using k-t accelerated 3D cine b-SSFP in pre-procedural assessment for transcatheter aortic valve implantation: a technical feasibility study
    Aouad, Pascale
    Jarvis, Kelly Brooke
    Botelho, Marcos Ferreira
    Serhal, Ali
    Blaisdell, Julie
    Collins, Louise
    Giri, Shivraman
    Kim, Daniel
    Markl, Michael
    Ricciardi, Mark J.
    Davidson, Charles J.
    Collins, Jeremy
    Carr, James
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2021, 37 (02): : 651 - 661
  • [29] Yet more evidence that non-aqueous myelin lipids can be directly imaged with ultrashort echo time (UTE) MRI on a clinical 3T scanner: a lyophilized red blood cell membrane lipid study
    Shin, Soo Hyun
    Moazamian, Dina
    Suprana, Arya
    Zeng, Chun
    Athertya, Jiyo S.
    Carl, Michael
    Ma, Yajun
    Jang, Hyungseok
    Du, Jiang
    NEUROIMAGE, 2024, 296
  • [30] Effect of uterine position and intrapelvic motions on the image quality of 3D T2-weighted MRI of the uterus: Can short prescans predict the non-diagnostic image quality?
    Tsuboyama, Takahiro
    Takei, Oki
    Okada, Atsuhiko
    Wada, Keiko
    Kuriyama, Keiko
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 130