Effect of single-phase flow maldistribution on the thermal performance of brazed plate heat exchangers
被引:7
|
作者:
Li, Wenzhe
论文数: 0引用数: 0
h-index: 0
机构:
Cent South Univ, Sch Energy Sci & Engn, Changsha 410083, Peoples R China
Univ Illinois, Dept Mech & Sci Engn, 1206 West Green St, Urbana, IL 61820 USACent South Univ, Sch Energy Sci & Engn, Changsha 410083, Peoples R China
Li, Wenzhe
[1
,2
]
Hrnjak, Pega
论文数: 0引用数: 0
h-index: 0
机构:
Univ Illinois, Dept Mech & Sci Engn, 1206 West Green St, Urbana, IL 61820 USA
CTS Creat Thermal Solut Inc, Urbana, IL 61802 USACent South Univ, Sch Energy Sci & Engn, Changsha 410083, Peoples R China
Hrnjak, Pega
[2
,3
]
机构:
[1] Cent South Univ, Sch Energy Sci & Engn, Changsha 410083, Peoples R China
[2] Univ Illinois, Dept Mech & Sci Engn, 1206 West Green St, Urbana, IL 61820 USA
[3] CTS Creat Thermal Solut Inc, Urbana, IL 61802 USA
This paper presents an experimental and numerical investigation of the effect of single-phase flow maldistribution on the thermal performance of brazed plate heat exchangers (BPHEs). A thermal performance model of the BPHEs is developed with the consideration of flow maldistribution among the channels. The proposed model is validated against the experimental results. The model simulations reveal that the flow maldistribution has a trivial impact on the overall thermal capacity of the BPHEs if two fluid streams are supplied from the same side of the heat exchangers; if two fluid streams are supplied from the opposite side, the overall thermal performance is significantly deteriorated due to mismatched flow distributions of two fluid streams. Moreover, other factors are also proven to act in this issue, including the number of plates, plate length, header/port size, sudden expansion flow at the heat exchanger entrance, and heat capacity rate ratio of two streams. They either directly change the flow distribution or potentially affect the thermal effectiveness of the BPHEs. Based on the simulation results, correlations are generated, which can evaluate the thermal capacity degradation due to flow maldistribution without the necessity of knowing the detailed flow distribution and building heat exchanger models.
机构:
Indian Inst Technol, Dept Mech Engn, Heat Transfer & Thermal Power Lab, Madras 600036, Tamil Nadu, IndiaIndian Inst Technol, Dept Mech Engn, Heat Transfer & Thermal Power Lab, Madras 600036, Tamil Nadu, India
Srihari, N.
Das, Sarit K.
论文数: 0引用数: 0
h-index: 0
机构:
Indian Inst Technol, Dept Mech Engn, Heat Transfer & Thermal Power Lab, Madras 600036, Tamil Nadu, IndiaIndian Inst Technol, Dept Mech Engn, Heat Transfer & Thermal Power Lab, Madras 600036, Tamil Nadu, India
机构:
Univ Illinois, Air Conditioning & Refrigerat Ctr, 1206 West Green St, Urbana, IL 61801 USAUniv Illinois, Air Conditioning & Refrigerat Ctr, 1206 West Green St, Urbana, IL 61801 USA
Li, Wenzhe
Hrnjak, Pega
论文数: 0引用数: 0
h-index: 0
机构:
Univ Illinois, Air Conditioning & Refrigerat Ctr, 1206 West Green St, Urbana, IL 61801 USA
Creat Thermal Solut, 2209 Willow Rd, Urbana, IL 61802 USAUniv Illinois, Air Conditioning & Refrigerat Ctr, 1206 West Green St, Urbana, IL 61801 USA
机构:Indian Inst Technol, Dept Mech Engn, Heat Transfer & Thermal Power Lab, Madras 600036, Tamil Nadu, India
Tereda, Fantu A.
Srihari, N.
论文数: 0引用数: 0
h-index: 0
机构:Indian Inst Technol, Dept Mech Engn, Heat Transfer & Thermal Power Lab, Madras 600036, Tamil Nadu, India
Srihari, N.
Sunden, Bengt
论文数: 0引用数: 0
h-index: 0
机构:Indian Inst Technol, Dept Mech Engn, Heat Transfer & Thermal Power Lab, Madras 600036, Tamil Nadu, India
Sunden, Bengt
Das, Sarit K.
论文数: 0引用数: 0
h-index: 0
机构:
Indian Inst Technol, Dept Mech Engn, Heat Transfer & Thermal Power Lab, Madras 600036, Tamil Nadu, IndiaIndian Inst Technol, Dept Mech Engn, Heat Transfer & Thermal Power Lab, Madras 600036, Tamil Nadu, India