The detection instrumentation and geometric design of clinical PET scanner: towards better performance and broader clinical applications

被引:0
|
作者
El Ouaridi, Abdallah [1 ]
Elcadi, Zakaria Ait [1 ,2 ]
Mkimel, Mounir [1 ]
Bougteb, Mustapha [1 ]
El Baydaoui, Redouane [1 ]
机构
[1] Hassan First Univ Settat, High Inst Hlth Sci, Lab Hlth Sci & Technol, Settat, Morocco
[2] Texas A&M Univ Qatar, Elect & Comp Engn, Doha 23874, Qatar
关键词
positron emission tomography; PET instrumentation; PET performance; clinical application; TIME-OF-FLIGHT; POSITRON-EMISSION-TOMOGRAPHY; MONTE-CARLO-SIMULATION; COUNT-RATE PERFORMANCE; EXTENDED AXIAL-FIELD; SILICON-PHOTOMULTIPLIER; TOF-PET; SCINTILLATION PROPERTIES; IMAGING PERFORMANCE; BISMUTH-GERMANATE;
D O I
10.1088/2057-1976/ad2d61
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Positron emission tomography (PET) is a powerful medical imaging modality used in nuclear medicine to diagnose and monitor various clinical diseases in patients. It is more sensitive and produces a highly quantitative mapping of the three-dimensional biodistribution of positron-emitting radiotracers inside the human body. The underlying technology is constantly evolving, and recent advances in detection instrumentation and PET scanner design have significantly improved the medical diagnosis capabilities of this imaging modality, making it more efficient and opening the way to broader, innovative, and promising clinical applications. Some significant achievements related to detection instrumentation include introducing new scintillators and photodetectors as well as developing innovative detector designs and coupling configurations. Other advances in scanner design include moving towards a cylindrical geometry, 3D acquisition mode, and the trend towards a wider axial field of view and a shorter diameter. Further research on PET camera instrumentation and design will be required to advance this technology by improving its performance and extending its clinical applications while optimising radiation dose, image acquisition time, and manufacturing cost. This article comprehensively reviews the various parameters of detection instrumentation and PET system design. Firstly, an overview of the historical innovation of the PET system has been presented, focusing on instrumental technology. Secondly, we have characterised the main performance parameters of current clinical PET and detailed recent instrumental innovations and trends that affect these performances and clinical practice. Finally, prospects for this medical imaging modality are presented and discussed. This overview of the PET system's instrumental parameters enables us to draw solid conclusions on achieving the best possible performance for the different needs of different clinical applications.
引用
收藏
页数:23
相关论文
共 38 条
  • [1] From PET/CT to PET/MRI: Advances in Instrumentation and Clinical Applications
    Hu, Zhenhua
    Yang, Weidong
    Liu, Haixiao
    Wang, Kun
    Bao, Chengpeng
    Song, Tianming
    Wang, Jing
    Tian, Jie
    MOLECULAR PHARMACEUTICS, 2014, 11 (11) : 3798 - 3809
  • [2] Performance evaluation in three geometric detection arrangement for Clinical PET:Simulation study
    Franze, Daniel L.
    Martins, Andre A. F.
    Moraes, Eder R.
    2017 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2017,
  • [3] Clinical trial design - towards better practices
    Correia, O
    Faergemann, J
    Nowicki, R
    Ro, BI
    JOURNAL OF THE EUROPEAN ACADEMY OF DERMATOLOGY AND VENEREOLOGY, 2005, 19 : 40 - 42
  • [4] Creeping towards broader clinical application of PET myocardial blood flow quantification
    Cremer, Paul C.
    DiFilippo, Frank P.
    Cerqueira, Manuel D.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2019, 26 (03) : 735 - 737
  • [5] Creeping towards broader clinical application of PET myocardial blood flow quantification
    Paul C. Cremer
    Frank P. DiFilippo
    Manuel D. Cerqueira
    Journal of Nuclear Cardiology, 2019, 26 : 735 - 737
  • [6] Design and performance simulation studies of a breast PET insert integrable into a clinical whole-body PET/MRI scanner
    Pommranz, C. M.
    Schmidt, F. P.
    Mannheim, J. G.
    Diebold, S. J.
    Tenzer, C.
    Santangelo, A.
    Pichler, B. J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (05):
  • [7] A ROTATING PET SCANNER USING BGO BLOCK DETECTORS - DESIGN, PERFORMANCE AND APPLICATIONS
    TOWNSEND, DW
    WENSVEEN, M
    BYARS, LG
    GEISSBUHLER, A
    TOCHONDANGUY, HJ
    CHRISTIN, A
    DEFRISE, M
    BAILEY, DL
    GROOTOONK, S
    DONATH, A
    NUTT, R
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (08) : 1367 - 1376
  • [8] Imaging study of a clinical PET scanner design using an optimal crystal thickness and scanner axial FOV
    Surti, Suleman
    Lee, Eunsin
    Werner, Matthew E.
    Karp, Joel S.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3390 - 3394
  • [9] Transforming Neurology and Psychiatry Organ-specific PET Instrumentation and Clinical Applications
    Taha, Ahmed
    Alassi, Amer
    Gjedde, Albert
    Wong, Dean F.
    PET CLINICS, 2024, 19 (01) : 95 - 103
  • [10] Physical and clinical performance of the mCT time-of-flight PET/CT scanner
    Jakoby, B. W.
    Bercier, Y.
    Conti, M.
    Casey, M. E.
    Bendriem, B.
    Townsend, D. W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (08): : 2375 - 2389