A Cascaded Multilevel Battery Energy Storage Based Parallel Dynamic Voltage Compensator for Medium Voltage Industrial Distribution Systems

被引:1
|
作者
Bai, Ziyi [1 ,2 ]
Xu, Da [3 ,4 ,5 ]
Wang, Tao [6 ]
Wong, Man-Chung [1 ,2 ,7 ]
机构
[1] Univ Macau, State Key Lab Internet Things Smart City, Macau 999078, Peoples R China
[2] Univ Macau, Fac Sci & Technol, Dept Elect & Comp Engn, Macau 999078, Peoples R China
[3] China Univ Geosci, Sch Automat, Wuhan 430074, Peoples R China
[4] Hubei Key Lab Adv Control & Intelligent Automat, Wuhan 430074, Peoples R China
[5] Minist Educ, Engn Res Ctr Intelligent Technol Geoexplorat, Wuhan 430074, Peoples R China
[6] Power China Zhongnan Engn Co Ltd, Changsha 410000, Peoples R China
[7] Univ Macau, State Key Lab Analog & Mixed Signal VLSI, Macau, Peoples R China
关键词
Power quality; Batteries; Energy storage; Switches; Topology; Medium voltage; Maintenance engineering; Battery energy storage; distribution systems; dynamic voltage compensator; power quality management; POWER QUALITY; RESTORER; STATCOM; CONVERTER;
D O I
10.1109/TII.2023.3265526
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This article proposes a cascaded multilevel battery energy storage based parallel dynamic voltage compensator (DVC) for medium voltage industrial distribution systems. In this parallel DVC, fast switch is series-connected for voltage sag detection, and cascaded multilevel battery energy storage is parallel-connected for voltage support during the voltage sag period. According to the grid-side voltage sags or not, corresponding circuits and three-layer control strategies are developed. While the feedforward proportional-integral control method is adopted in the outer layer to track the ideal compensation voltage when the grid-side voltage sags, the ideal compensation current when the grid-side voltage does not sag is obtained through battery charging current as well as reactive power, harmonics, and negative sequence load current components. In order to cope with parameter differences in cascaded multilevel battery energy storage, the middle layer interphase and the inner layer intermodular state of charge equalization control are adopted in two scenarios. Furthermore, the parallel DVC is quantitatively compared with series DVC in the aspect of required battery capacity, and their advantages and disadvantages are systematically analyzed. Case studies are performed to verify the effectiveness and superiority of the proposed methodology on voltage support.
引用
收藏
页码:873 / 885
页数:13
相关论文
共 50 条
  • [41] A High-Frequency Link Multilevel Cascaded Medium-Voltage Converter for Direct Grid Integration of Renewable Energy Systems
    Islam, Md. Rabiul
    Guo, Youguang
    Zhu, Jianguo
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (08) : 4167 - 4182
  • [42] Smart coordination of battery energy storage systems for voltage control in distribution networks with high penetration of photovoltaics
    Unigwe, Obinna
    Okekunle, Dahunsi
    Kiprakis, Aristides
    JOURNAL OF ENGINEERING-JOE, 2019, (18): : 4738 - 4742
  • [43] Distributed Control of Battery Energy Storage Systems for Voltage Regulation in Distribution Networks With High PV Penetration
    Zeraati, Mehdi
    Golshan, Mohamad Esmail Hamedani
    Guerrero, Josep M.
    IEEE TRANSACTIONS ON SMART GRID, 2018, 9 (04) : 3582 - 3593
  • [44] Control of Reduced Rating Dynamic Voltage Restorer with Battery Energy Storage System
    Jayaprakash, P.
    Singh, Bhim
    Kothari, D. P.
    Chandra, Ambrish
    Kamal-Al-Haddad
    2008 JOINT INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON) AND IEEE POWER INDIA CONFERENCE, VOLS 1 AND 2, 2008, : 508 - +
  • [45] MW-Scale Medium Voltage Cascaded H-bridge Battery Storage System Based on Virtual Synchronous Generators
    Hasabelrasul, Hashim
    Yan, Xiangwu
    Gadalla, Abuzaid Saeed
    TENCON 2017 - 2017 IEEE REGION 10 CONFERENCE, 2017, : 285 - 290
  • [46] Cost-benefit analysis of battery storage in medium-voltage distribution networks
    Mateo, Carlos
    Reneses, Javier
    Rodriguez-Calvo, Andrea
    Frias, Pablo
    Sanchez, Alvaro
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2016, 10 (03) : 815 - 821
  • [47] Location and Sizing of Battery Energy Storage Units in Low Voltage Distribution Networks
    Mazza, Andrea
    Mirtaheri, Hamidreza
    Chicco, Gianfranco
    Russo, Angela
    Fantino, Maurizio
    ENERGIES, 2020, 13 (01)
  • [48] Analysis of a dynamic voltage compensator with reduced switch-count and absence of energy storage system
    Silva, SM
    da Silveira, SB
    Reis, AD
    Cardoso, BJ
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2005, 41 (05) : 1255 - 1262
  • [49] A combined uninterruptible power supply and dynamic voltage compensator using a flywheel energy storage system
    Weissbach, RS
    Karady, GG
    Farmer, RG
    IEEE TRANSACTIONS ON POWER DELIVERY, 2001, 16 (02) : 265 - 270
  • [50] A voltage-based fault location algorithm for medium voltage active distribution systems
    Arsoniadis, Charalampos G.
    Apostolopoulos, Christos A.
    Georgilakis, Pavlos S.
    Nikolaidis, Vassilis C.
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 196