The relationship between maternal anemia and electronic fetal monitoring patterns

被引:0
|
作者
Beermann, Shannon E. [1 ]
Watkins, Virginia Y. [2 ]
Frolova, Antonina I. [1 ]
Raghuraman, Nandini [1 ]
Cahill, Alison G. [3 ]
机构
[1] Washington Univ, Sch Med, Dept Obstet & Gynecol, St Louis, MO 63130 USA
[2] Duke Univ Hlth Syst, Dept Obstet & Gynecol, Durham, NC USA
[3] Univ Texas Austin, Dell Med Sch, Dept Womens Hlth, Austin, TX USA
关键词
anemia; anemia in pregnancy; category 2 fetal monitoring; composite category 2 patterns; electronic fetal monitoring; fetal tolerance of labor; high-risk category 2 features; intrapartum anemia; maternal anemia; total deceleration area; IRON-DEFICIENCY; HEMATOCRIT; PREGNANCY;
D O I
10.1016/j.ajog.2023.04.018
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
BACKGROUND: Anemia is a commonly diagnosed comorbidity in pregnancy that is associated with increased risk of maternal and neonatal complications. Recent data demonstrate that maternal anemia is associated with higher umbilical artery and umbilical vein O-2 content at the time of delivery.OBJECTIVE: This study aimed to examine the relationship between maternal anemia and electronic fetal monitoring patterns associated with fetal hypoxia.STUDY DESIGN: This is a secondary analysis of a prospective cohort study of singleton term deliveries with cord gases and universal complete blood count collected on admission between 2010 and 2014. Maternal anemia was defined as hemoglobin <= 11.0 g/dL on admission. The primary outcome was a composite of high-risk category 2 electronic fetal monitoring features in the last 60 minutes before delivery (recurrent late and/or variable decelerations, minimal variability, tachycardia, or >1 prolonged deceleration); secondary outcomes were total deceleration area and total deceleration area >90th percentile. Of the 8580 patients in the original study, 8196 were included in the analysis. Outcomes were compared between patients with and without anemia. Multivariable lo-gistic regression was used to adjust for potentially confounding factors, including hypertensive disorders of pregnancy and induction of labor.RESULTS: Of the 8196 patients with complete blood count on admission and fetal monitoring data, 2672 (32.6%; 2672/8196) were anemic and 5524 (67.4%; 5524/8196) were not. Patients with anemia were significantly less likely to have composite high-risk category 2 features on electronic fetal monitoring (34.2% vs 32.0%; adjusted risk ratio, 0.93; 95% confidence interval, 0.86-0.99). Women with anemia also had decreased total deceleration area and were less likely to have total deceleration area >90th percentile (18.7% vs 16.2%; adjusted risk ratio, 0.85; 95% confidence interval, 0.77-0.94).CONCLUSION: Patients with anemia are less likely to have high -risk category 2 electronic fetal monitoring features associated with fetal hypoxia. This finding is consistent with the association between maternal anemia and increased umbilical cord O-2 content, and suggests that maternal anemia may be protective against intrapartum fetal hypoxia.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Evaluating the Sensitivity of Electronic Fetal Monitoring Patterns for the Prediction of Intraventricular Hemorrhage
    Hannaford, Karen E.
    Stout, Molly J.
    Smyser, Chris D.
    Mathur, Amit
    Cahill, Alison G.
    AMERICAN JOURNAL OF PERINATOLOGY, 2016, 33 (14) : 1420 - 1425
  • [32] Electronic fetal monitoring patterns associated with respiratory morbidity in term neonates
    Liu, Lucy
    Tuuli, Methodius G.
    Roehl, Kimberly A.
    Odibo, Anthony O.
    Macones, George A.
    Cahill, Alison G.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2015, 213 (05) : 681.e1 - 681.e6
  • [33] The relationship between maternal anemia and umbilical cord oxygen content at delivery
    Watkins, Virginia Y.
    Frolova, Antonina I.
    Stout, Molly J.
    Carter, Ebony B.
    Macones, George A.
    Cahill, Alison G.
    Raghuraman, Nandini
    AMERICAN JOURNAL OF OBSTETRICS & GYNECOLOGY MFM, 2021, 3 (01)
  • [34] MATERNAL REACTIONS TO FETAL MONITORING
    SHIELDS, D
    AMERICAN JOURNAL OF NURSING, 1978, 78 (12) : 2110 - 2112
  • [35] RELATIONSHIP BETWEEN ACUTE FETAL DISTRESS AND MATERNAL PLACENTAL FETAL CIRCULATIONS IN SEVERE PREECLAMPSIA
    YANG, JM
    WANG, KG
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1995, 74 (06) : 419 - 424
  • [36] MATERNAL ATTITUDES TO FETAL MONITORING
    HANSEN, PK
    SMITH, SF
    NIM, J
    NELDAM, S
    OSLER, M
    EUROPEAN JOURNAL OF OBSTETRICS GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 1985, 20 (01): : 43 - 51
  • [37] The maternal-fetal relationship
    van Dis, J
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2003, 289 (13): : 1696 - 1696
  • [38] MATERNAL AND FETAL OUTCOME IN PREGNANCY WITH SEVERE ANEMIA
    Nisty, Rameshwari M.
    Nisty, Gangambika M.
    Patil, Amrutha
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2014, 3 (15): : 4132 - 4136
  • [39] MATERNAL ANEMIA AND FETAL BIRTH-WEIGHT
    HARRISON, KA
    IBEZIAKO, PA
    JOURNAL OF OBSTETRICS & GYNAECOLOGY OF THE BRITISH COMMONWEALTH, 1973, 80 (09): : 798 - 804
  • [40] Relationship Between Umbilical Cord Gas Values and Neonatal Outcomes Implications for Electronic Fetal Heart Rate Monitoring
    Johnson, Grace J.
    Salmanian, Bahram
    Denning, Stacie G.
    Belfort, Michael A.
    Sundgren, Nathan C.
    Clark, Steven L.
    OBSTETRICS AND GYNECOLOGY, 2021, 138 (03): : 366 - 373