Temperature-Tuning Desorption Ionization for Ambient Mass Spectrometry

被引:5
|
作者
Li, Ningxi [1 ]
Cai, Zhijun [1 ]
Zhang, Zhongyao [1 ]
Zhang, Wenpeng [1 ]
Ma, Xiaoxiao [1 ]
Zhou, Xiaoyu [1 ]
Ouyang, Zheng [1 ]
机构
[1] Tsinghua Univ, Dept Precis Instrument, State Key Lab Precis Measurement Technol & Instrum, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
PAPER SPRAY;
D O I
10.1021/acs.analchem.3c01942
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the past decade, mass spectrometry (MS) has been widelyusedfor a broad range of on-site applications. This is largely attributedto the rapid advancement of technologies, such as ambient ionizationand mass spectrometer miniaturization. Here, we report the developmentof the temperature-tuning desorption ionization (TTDI) method forversatile on-site applications using a miniature MS system. A uniquefeature of TTDI is its dynamic temperature range applicable from 30to 800 & DEG;C, which enables optimal desorption ionization appliedfor chemical and biological compounds through tuning the temperatureat the sampling spot. The versatility of TTDI has been demonstratedthrough on-site MS analysis of a variety of samples, such as explosiveson surfaces, drugs of abuse in biofluids, and screening biomarkersin tissues.
引用
收藏
页码:11099 / 11105
页数:7
相关论文
共 50 条
  • [1] Ambient desorption ionization mass spectrometry
    Venter, Andre
    Nefliu, Marcela
    Cooks, R. Graham
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2008, 27 (04) : 284 - 290
  • [2] Desorption electrospray ionization ambient mass spectrometry
    Beatriz Pomilio, Alicia
    Alberto Bernatene, Eduardo
    Alberto Vitale, Arturo
    ACTA BIOQUIMICA CLINICA LATINOAMERICANA, 2011, 45 (01): : 47 - 79
  • [3] Biodiesel Oxidation Monitored by Ambient Desorption/Ionization Mass Spectrometry
    Godoy, Adriana T.
    Pereira, Gustavo G.
    Ferreira, Lucas L.
    Cunha, Ildenize B. S.
    Barrera-Arellano, Daniel
    Daroda, Romeu J.
    Eberlin, Marcos N.
    Alberici, Rosana M.
    ENERGY & FUELS, 2013, 27 (12) : 7455 - 7459
  • [4] Ambient molecular imaging by desorption electrospray ionization mass spectrometry
    Wiseman, Justin M.
    Ifa, Demian R.
    Venter, Andre
    Cooks, R. Graham
    NATURE PROTOCOLS, 2008, 3 (03) : 517 - 524
  • [5] Ambient molecular imaging by desorption electrospray ionization mass spectrometry
    Justin M Wiseman
    Demian R Ifa
    Andre Venter
    R Graham Cooks
    Nature Protocols, 2008, 3 : 517 - 524
  • [6] Thermal desorption ambient ionization mass spectrometry for emergency toxicology
    Su, Hung
    Huang, Min-Zong
    Shiea, Jentaie
    Lee, Chi-Wei
    MASS SPECTROMETRY REVIEWS, 2023, 42 (05) : 1828 - 1847
  • [7] Ambient Eberlin reactions via desorption electrospray ionization mass spectrometry
    Sparrapan, Regina
    Eberlin, Livia S.
    Haddad, Renato
    Cooks, R. Graham
    Eberlin, Marcos N.
    Augusti, Rodinei
    JOURNAL OF MASS SPECTROMETRY, 2006, 41 (09): : 1242 - 1246
  • [8] Ambient desorption/ionization mass spectrometry for direct solid material analysis
    Shrestha, Sarmila Amatya
    Cha, Sangwon
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2021, 144
  • [9] Comparison of Three Plasma Sources for Ambient Desorption/Ionization Mass Spectrometry
    McKay, Kirsty
    Salter, Tara L.
    Bowfield, Andrew
    Walsh, James L.
    Gilmore, Ian S.
    Bradley, James W.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2014, 25 (09) : 1528 - 1537
  • [10] Mass spectrometry sampling under ambient conditions with desorption electrospray ionization
    Takáts, Z
    Wiseman, JM
    Gologan, B
    Cooks, RG
    SCIENCE, 2004, 306 (5695) : 471 - 473