Evaluation of the marginal and internal fit of CAD/CAM crowns designed using three different dental CAD programs: a 3-dimensional digital analysis study

被引:6
|
作者
Farah, Ra'fat, I [1 ]
Alresheedi, Bandar [1 ]
机构
[1] Qassim Univ, Coll Dent, Dept Prosthet Dent Sci, POB 6700, Al Mulaydah 51452, Qassim, Saudi Arabia
关键词
CAD; CAM; Computer-aided design; Internal fit; Marginal fit; Triple-scan protocol; ACCURACY; TECHNOLOGY; SYSTEMS; COPINGS; SPACE;
D O I
10.1007/s00784-022-04720-6
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives The purpose of this in vitro study was to assess and compare the marginal and internal fit of machine-milled crowns designed using three different CAD software programs. Materials and methods Digital impressions of the master zirconia casts containing the prepared molar were obtained using an intraoral scanner. The obtained standard tessellation language (STL) files were imported into three CAD software programs (Multi-CAD, Blue-Sky CAD, and InLab), and crown designs were generated. Crown design digital STL files were used to mill crowns with a five-axis dental milling machine. The internal and marginal fits of the fabricated crowns over the master-prepared tooth were assessed using the triple-scan protocol and digital analysis techniques. The 3D marginal and internal fit values of the fabricated crowns from the designs generated by the three CAD programs were evaluated and statistically compared using one-way analysis of variance (ANOVA) and post hoc Tukey's tests (alpha = 0.05). Results There were no significant differences in the internal fit of the crowns designed by the three CAD programs (p > 0.05). However, there were significant differences in the mean marginal fit (p = 0.009) of the crowns. The marginal fit values for the InLab-designed crowns were significantly better than those for Multi-CAD (p = 0.03) and Blue-Sky CAD (p = 0.012) groups. Conclusions All three CAD programs can design clinically acceptable crowns in terms of internal and marginal fit. InLab crowns outperformed the Multi-CAD and Blue-Sky CAD programs in terms of marginal fit.
引用
收藏
页码:263 / 271
页数:9
相关论文
共 50 条
  • [21] Comparative evaluation of internal and marginal fit of interim crowns fabricated by CAD/CAM milling and two different 3D printing systems - An in vitro study
    Thakare A.
    Ramesh S.
    Patil V.
    Meenakshi S.
    Ramu R.
    Byakodi R.
    Materials Today: Proceedings, 2022, 57 : A1 - A9
  • [22] Three-Dimensional Digital Evaluation of the Fit of Endocrowns Fabricated from Different CAD/CAM Materials
    Zimmermann, Moritz
    Valcanaia, Andre
    Neiva, Gisele
    Mehl, Albert
    Fasbinder, Dennis
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (02): : E504 - E509
  • [23] Comparison of marginal adaptation and internal fit of monolithic lithium disilicate crowns produced by 4 different CAD/CAM systems
    Ferrairo, Brunna Mota
    Piras, Fernanda Furtado
    Lima, Feranda Ferruzzi
    Honorio, Heitor Marques
    Hungaro Duarte, Marco Antonio
    Sanches Borges, Ana Flavia
    Rubo, Jose Henrique
    CLINICAL ORAL INVESTIGATIONS, 2021, 25 (04) : 2029 - 2036
  • [24] Comparison of marginal adaptation and internal fit of monolithic lithium disilicate crowns produced by 4 different CAD/CAM systems
    Brunna Mota Ferrairo
    Fernanda Furtado Piras
    Feranda Ferruzzi Lima
    Heitor Marques Honório
    Marco Antonio Hungaro Duarte
    Ana Flávia Sanches Borges
    José Henrique Rubo
    Clinical Oral Investigations, 2021, 25 : 2029 - 2036
  • [25] Clinical evaluation of the fit of lithium disilicate crowns fabricated with three different CAD-CAM systems
    Ahn, Jong-Ju
    Bae, Eun-Bin
    Lee, Jin-Ju
    Choi, Jae-Won
    Jeon, Young-Chan
    Jeong, Chang-Mo
    Yun, Mi-Jung
    Lee, So-Hyoun
    Lee, Kyu-Bok
    Huh, Jung-Bo
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (02): : 239 - 247
  • [26] Marginal Fit Evaluation of CAD/CAM All Ceramic Crowns Obtained by Two Digital Workflows: An In Vitro Study Using Micro-CT Technology
    Duqum, Ibrahim Salim
    Brenes, Christian
    Mendonca, Gustavo
    Prado Naves Carneiro, Thiago Almedia
    Cooper, Lyndon F.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (09): : 1037 - 1043
  • [27] Evaluation of Marginal and Internal Adaptation of Endocrowns Fabricated from Three Different CAD/CAM Materials
    Hasanzade, Mahya
    Moharrami, Mohammad
    Alikhasi, Marzieh
    EUROPEAN JOURNAL OF PROSTHODONTICS AND RESTORATIVE DENTISTRY, 2019, 27 (04): : 164 - 171
  • [28] Marginal and Internal Fitness of Full Contour CAD/CAM Fabricated Zirconia Crowns using Different Digital Intra-oral Scanners (An In vitro Study)
    Al-Hawwaz, Zahraa M.
    Ibraheem, Adel F.
    JOURNAL OF PURE AND APPLIED MICROBIOLOGY, 2018, 12 (02): : 839 - 844
  • [29] Marginal and internal fit of posterior three-unit fixed zirconia dental prostheses fabricated with two different CAD/CAM systems and materials
    Schoenberger, Joana
    Erdelt, Kurt-Juergen
    Baeumer, Daniel
    Beuer, Florian
    CLINICAL ORAL INVESTIGATIONS, 2017, 21 (08) : 2629 - 2635
  • [30] Marginal and internal fit of posterior three-unit fixed zirconia dental prostheses fabricated with two different CAD/CAM systems and materials
    Joana Schönberger
    Kurt-Jürgen Erdelt
    Daniel Bäumer
    Florian Beuer
    Clinical Oral Investigations, 2017, 21 : 2629 - 2635