Comparison of pulsed field ablation and cryoballoon ablation for pulmonary vein isolation

被引:15
|
作者
Schipper, Jan-Hendrik [1 ,2 ]
Steven, Daniel [1 ]
Lueker, Jakob [1 ]
Woermann, Jonas [1 ]
van den Bruck, Jan-Hendrik [1 ]
Filipovic, Karlo [1 ]
Dittrich, Sebastian [1 ]
Scheurlen, Cornelia [1 ]
Erlhoefer, Susanne [1 ]
Pavel, Friederike [1 ]
Sultan, Arian [1 ]
机构
[1] Univ Cologne, Heart Ctr, Dept Electrophysiol, Cologne, Germany
[2] Univ Cologne, Heart Ctr, Dept Electrophysiol, Kerpener Str 62, D-50937 Cologne, Germany
关键词
atrial fibrillation ablation; cryoballoon ablation; pulmonary vein isolation; Pulsed field ablation; PAROXYSMAL ATRIAL-FIBRILLATION; AUTONOMIC DENERVATION; CRYOABLATION; OUTCOMES;
D O I
10.1111/jce.16056
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Pulmonary vein isolation (PVI) remains the cornerstone in the treatment of atrial fibrillation (AF). PVI using cryoballoon (CB) technology has emerged as a standard procedure in many centers. Recently, pulsed field ablation (PFA) has been introduced and used to achieve PVI. First data show high acute and favorable long-term outcomes. So far, data comparing these new "single shot" devices are sparse. We sought to compare procedural and outcome data for first time PFA users versus CB in patients undergoing de novo PVI. Furthermore, potentially postprocedural discomfort and affection of autonomic ganglia were assessed. Methods and Results: A retrospective analysis and comparison of all de novo PVIs with PFA and CB was performed. Furthermore, PFA PVI learning curve was evaluated. During follow-up, repeat outpatient visits and Holter electrocardiogram were performed to analyze arrhythmia-free survival. Discomfort analysis was obtained by prescribed analgesic medication within first 48 h after PVI. Potential changes in heart rate ( HR) between baseline and at 3- month follow-up were evaluated. A total of 108 patients ( 54 PFA and 54 CB; PFA; 33 (30%) female) with paroxysmal and persistent AF were analyzed. Type of AF was comparable ( Patients suffering from PAF: PFA: 16 (30%), CB: 17 (31%), p = 1.0). In 107 (99%) patients, successful PVI was achieved. Transient phrenic palsy omitted complete PVI in one CB patient. A trend for a shorter overall procedure duration was observed in the PFA group (PFA: 64.5 +/- 17.5 min; CB: 73.0 +/- 24.8 min; p = 0.07). Excluding LA mapping time (first 14 cases), procedure time was significantly shorter using PFA (PFA: 58.0 +/- 12.5 min, CB: 73.0 +/- 24.8 min, p = 0.0001). Fluoroscopy time was significantly longer for PFA (PFA: 15.3 +/- 4.7min, CB: 12.3 +/- 5.3min; p = 0.001), but significantly less contrast medium was used (PFA: 12 +/- 6 mL; CB: 51 +/- 29 mL, p < 0.0001). Subgroup analysis of the PFA group revealed a significant shortening of procedure duration over time (first tertile: 72.7 +/- 13.5 min, second tertile: 67.3 +/- 21.7 min, third tertile: 53.4 +/- 9.8 min, first vs. third tertile p < 0.0001). Two cardiac tamponades occurred in the PFA group ( p = 0.495), of which one was most likely related to complex transseptal puncture. In the first 48 h after PVI, the number of prescribed analgesics due to postprocedural pain was equal between both groups (PFA: 7 (13%) patients, CB: 10 (19%) patients, p = 0.598). After a FU of 273 +/- 129 days, 35 of 47 patients ( 74%) after PFA and 36 of 50 patients (72%) after CB PVI were free of any atrial arrhythmia (HR: 0.98, p = 0.88). Only in the PFA group, a significant increase in HR 3 months after PVI was observed ( pre- PVI: 61 +/- 8 beats/min, post-PVI: 65 +/- 9 beats/min, p = 0.008). Conclusion: The new PFA technology is equally effective and safe as compared to CB for complete PVI with potentially shorter procedure time and significantly less contrast medium. However, AF recurrence rates after PFA PVI seem to be comparable to CB PVI.
引用
收藏
页码:2019 / 2026
页数:8
相关论文
共 50 条
  • [41] Pulsed-field vs cryoballoon vs radiofrequency ablation: Outcomes after pulmonary vein isolation in patients with persistent atrial fibrillation
    Kueffer, Thomas
    Stettler, Robin
    Maurhofer, Jens
    Madaffari, Antonio
    Stefanova, Anita
    Iqbal, Salik ur Rehman
    Thalmann, Gregor
    Kozhuharov, Nikola A.
    Galuszka, Oskar
    Servatius, Helge
    Haeberlin, Andreas
    Noti, Fabian
    Tanner, Hildegard
    Roten, Laurent
    Reichlin, Tobias
    HEART RHYTHM, 2024, 21 (08) : 1227 - 1235
  • [42] Comparison of advanced generation cryoballoon ablation and ablation index-guided pulmonary vein isolation with non-pulmonary vein trigger induction test and additional ablation in paroxysmal atrial fibrillation
    Yasuyuki Egami
    Masami Nishino
    Hiroaki Nohara
    Shodai Kawanami
    Hiroki Sugae
    Kohei Ukita
    Akito Kawamura
    Hitoshi Nakamura
    Koji Yasumoto
    Masaki Tsuda
    Naotaka Okamoto
    Yasuharu Matsunaga-Lee
    Masamichi Yano
    Jun Tanouchi
    Journal of Interventional Cardiac Electrophysiology, 2023, 66 : 1571 - 1580
  • [43] Cryoballoon ablation beyond pulmonary vein isolation in the setting of persistent atrial fibrillation
    Miraglia, Vincenzo
    Bisignani, Antonio
    Pannone, Luigi
    Iacopino, Saverio
    Chierchia, Gian-Battista
    de Asmundis, Carlo
    EXPERT REVIEW OF MEDICAL DEVICES, 2022, 19 (05) : 431 - 439
  • [44] MRI characterization of cryoballoon and radiofrequency ablation lesions after pulmonary vein isolation
    Cabanas Grandio, P.
    Bisbal, F.
    Gomez Pulido, F.
    Guiu, E.
    Calvo, M.
    Berruezo, A.
    Prat, S.
    Perea, R. J.
    Brugada, J.
    Mont, L.
    EUROPEAN HEART JOURNAL, 2014, 35 : 428 - 428
  • [45] A PRACTICAL MODEL OF BALLOON/TISSUE CONTACT IN PULMONARY VEIN ISOLATION WITH CRYOBALLOON ABLATION
    Smith, David J.
    Murthy, Sam
    Liao, Yu
    PROCEEDINGS OF THE 2024 DESIGN OF MEDICAL DEVICES CONFERENCE, DMD2024, 2024,
  • [46] Comparison of procedural analgosedation in patients undergoing pulsed field ablation or cryoballoon ablation for atrial fibrillation
    Wahedi, R.
    Willems, S.
    Jularic, M.
    Hartmann, J.
    Anwar, O.
    Dickow, J.
    Harloff, T.
    Gessler, N.
    Gunawardene, M.
    EUROPEAN HEART JOURNAL, 2024, 45
  • [47] Efficacy and safety of cryoballoon pulmonary vein isolation for paroxysmal and persistent atrial fibrillation: A comparison with radiofrequency ablation
    Choi, Ji-Hoon
    Park, Seung-Jung
    Park, Kyoung-Min
    Kim, June Soo
    On, Young Keun
    PLOS ONE, 2022, 17 (07):
  • [48] Characteristics of atrial tachycardias after pulmonary vein isolation: comparison between cryoballoon and circumferential radiofrequency ablation
    Mikhaylov, E.
    Van Belle, Y.
    Janse, P.
    Lebedev, D.
    Kanidieva, A.
    Jordaens, L.
    Szili-Torok, T.
    EUROPEAN HEART JOURNAL, 2009, 30 : 813 - 813
  • [49] Comparison of ultralow temperature cryoablation and classical cryoballoon ablation for pulmonary vein isolation in patients with atrial fibrillation
    Rudolph, I.
    Bohnen, J.
    Siebermair, J.
    Rattka, M.
    Rassaf, T.
    Wakili, R.
    EUROPEAN HEART JOURNAL, 2023, 44
  • [50] Pulsed-field ablation for pulmonary vein isolation in humans: Endoscopic observations of the esophagus
    Neuzil, Petr
    Petru, Jan
    Funosako, Moritoshi
    Chovanec, Milan
    Kralovec, Stepan
    Kuroki, Kenji
    Koruth, Jacob
    Pare, Michael
    Schneider, Christopher
    Eggert, Charles
    Reddy, Vivek
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (09) : 1750 - 1750