Non-enzymatic glucose sensing using a nickel hydroxide/chitosan modified screen-printed electrode incorporated into a flow injection analysis system

被引:3
|
作者
McCormick, Wesley J. [1 ]
Mcloughlin, Eva [1 ]
Mccrudden, Denis [1 ]
机构
[1] Atlantic Technol Univ, Dept Life & Phys Sci, Letterkenny F92 FC93, Donegal, Ireland
关键词
SENSORS; NANOCOMPOSITE; FOAM; FILM;
D O I
10.1039/d3ay01145c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This works presents a novel screen-printed carbon electrode modified with nickel hydroxide nanoparticles and chitosan (Ni(OH)2/CS/SPCE) for the non-enzymatic flow injection amperometric detection of glucose. The electrode was modified by drop-casting a suspension of the synthesised nanocomposite onto the screen-printed electrode and dried for 1 hour at room temperature. EDX analysis was used to investigate the chemical composition of the electrode before and after modifying. The electrochemical response of the unmodified SPCE and modified electrode was initially investigated by cyclic voltammetry (CV) using 0.1 M NaOH as the supporting electrolyte. CVs showed catalytic activity for glucose oxidation using the Ni(OH)2/CS/SPCE at 0.55 V. During flow injection analysis (FIA), 0.60 V and 1.5 mL min-1 were identified as the optimal potential and flow rate, respectively. A wide linear range of detection was observed (0.2 to 10.0 mM) with a sensitivity and limit of detection of 913 mu A mM-1 cm-2 and 0.0174 mM, respectively. The modified electrode also displayed excellent repeatability (RSD = 0.47%, n = 20) and good reproducibility (RSD = 2.52%, n = 6). The modified electrode was shown to be very selectivity for glucose over other interferences commonly found in human blood samples. The practicality of the developed flow injection-amperometric system (FIA-Amp) was validated by the quantification of glucose in real serum samples, where results were in close agreement with those obtained from the local hospital. This works presents a novel screen-printed carbon electrode modified with nickel hydroxide nanoparticles and chitosan (Ni(OH)2/CS/SPCE) for the non-enzymatic flow injection amperometric detection of glucose.
引用
收藏
页码:5071 / 5077
页数:7
相关论文
共 50 条
  • [21] Flow injection analysis of an ultratrace amount of arsenite using a Prussian blue-modified screen-printed electrode
    Zen, JM
    Chen, PY
    Kumar, AS
    ANALYTICAL CHEMISTRY, 2003, 75 (21) : 6017 - 6022
  • [22] A Non-Enzymatic Electrochemical Sensor for Glyphosate Adopting Surface Modified Screen-Printed Electrodes
    Janjani, Prachi
    Bhardwaj, Upasana
    Gupta, Ragini
    Kushwaha, Himmat Singh
    ACS APPLIED ENGINEERING MATERIALS, 2023, 1 (01): : 359 - 368
  • [23] Non-enzymatic electrochemical determination of creatinine using a novel screen-printed microcell
    Fava, Elson Luiz
    do Prado, Thiago Martimiano
    Garcia-Filho, Amauri
    Silva, Tiago Almeida
    Cincotto, Fernando Henrique
    de Moraes, Fernando Cruz
    Faria, Ronaldo Censi
    Fatibello-Filho, Orlando
    TALANTA, 2020, 207
  • [24] Electrochemical non-enzymatic sensing of glycoside toxins by boronic acid functionalized nano-composites on screen-printed electrode
    Shi, Zhenghan
    Lu, Yanli
    Chen, Zetao
    Cheng, Chen
    Xu, Jie
    Zhang, Qingqing
    Yan, Zupeng
    Luo, Zisheng
    Liu, Qingjun
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 329
  • [25] Sequential Injection Amperometric Determination of Glucose in Saliva Using a Screen-Printed Electrode Modified with a Gold–Cobalt Binary System
    L. G. Shaidarova
    I. A. Chelnokova
    I. A. Gafiatova
    A. V. Gedmina
    H. C. Budnikov
    Journal of Analytical Chemistry, 2023, 78 : 372 - 377
  • [26] Chitosan Modified Screen-Printed Carbon Electrode for Sensitive Analysis of Heavy Metals
    Khaled, Elmorsy
    Hassan, H. N. A.
    Habib, I. H. I.
    Metelka, Radovan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2010, 5 (02): : 158 - 167
  • [27] MIL-88B(Fe) MOF modified screen-printed electrodes for non-enzymatic electrochemical sensing of malathion
    Janjani, Prachi
    Bhardwaj, Upasana
    Agarwal, Madhu
    Gupta, Ragini
    Kushwaha, Himmat Singh
    ENVIRONMENTAL TECHNOLOGY, 2024, 45 (13) : 2649 - 2659
  • [28] Nanopyramid copper structures on screen-printed carbon electrode for high-performance non-enzymatic glucose sensing: A cost-effective and scalable approach
    Bakhshi, Sahar
    Rahmanipour, Mahsa
    Amirsoleimani, Amir R.
    Rezazadeh, Mostafa
    Siampour, Hossein
    Moshaii, Ahmad
    SENSING AND BIO-SENSING RESEARCH, 2024, 46
  • [29] Amperometric determination of bonded glucose with an MnO2 and glucose oxidase bulk-modified screen-printed electrode using flow-injection analysis
    Turkusic, E
    Kalcher, J
    Kahrovic, E
    Beyene, NW
    Moderegger, H
    Sofic, E
    Begic, S
    Kalcher, K
    TALANTA, 2005, 65 (02) : 559 - 564
  • [30] Non-Enzymatic Amperometric Glucose Screen-Printed Sensors Based on Copper and Copper Oxide Particles
    Guati, Carlota
    Gomez-Coma, Lucia
    Fallanza, Marcos
    Ortiz, Inmaculada
    APPLIED SCIENCES-BASEL, 2021, 11 (22):