Use of robotic C-arm cone-beam computed tomography in surgical stabilization of rib fractures

被引:1
|
作者
Yen, Ming-Hong [1 ]
Liu, Tsu-Hao [1 ]
Liu, Jung -Sen [1 ,2 ]
Yim, Shelly [1 ,3 ]
机构
[1] Cathay Gen Hosp, Dept Chest Surg, Taipei 10630, Taiwan
[2] Fu Jen Catholic Univ, Sch Med, New Taipei City 24205, Taiwan
[3] Cathay Gen Hosp, Dept Surg, Div Thorac Surg, 280,Sec 4,Renai Rd, Taipei 106, Taiwan
关键词
Rib fractures; Hybrid operating room; Cone-beam computed tomography; ASSISTED THORACOSCOPIC SURGERY; FLAIL CHEST; LOCALIZATION; METAANALYSIS; MANAGEMENT; FIXATION; PITFALLS;
D O I
10.1016/j.injury.2023.111087
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: The effectiveness of using intraoperative robotic C-arm cone-beam computerized tomography (CT) to locate rib fractures during surgery was compared to using pre-operative CT. Methods: Patients diagnosed with multiple rib fracture and treated surgically in the hospital between January 2019 and September 2020 were included. The study included two groups of patients. One group had their rib fractures identified using pre-operative CT, while the other group had their fractures localized using intraoperative cone-beam CT during surgery. The operative time, blood loss, number of incisions, length of incision, duration of chest drains, visual analogue scale (VAS) score, and duration of post-operation stays were measured. Results: A total of 12 patients received intraoperative cone-beam CT, while the remaining 18 patients only received pre-operative CT. Statistical analysis showed that the group treated with cone-beam CT had lower blood loss (p = 0.012), shorter incisions (p = 0.005), and better post-operation VAS scores (p = 0.027). There were also non-significant trends towards fewer incisions, shorter operation times, and shorter duration of chest drains in the group treated with cone-beam CT. Conclusions: Intraoperative localization of rib fracture sites with cone-beam CT is an effective method for rib fracture stabilization.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Development of a mobile C-arm platform for cone-beam CT guidance of surgical procedures
    Siewerdsen, J
    Moseley, D
    Kim, S
    Burch, S
    Bisland, S
    Bogaards, A
    Jaffray, D
    MEDICAL PHYSICS, 2004, 31 (06) : 1820 - 1820
  • [22] Cone-Beam Computed Tomography on a Mobile C-Arm: Novel Intraoperative Imaging Technology for Guidance of Head and Neck Surgery
    Chan, Yvonne
    Siewerdsen, Jeffrey H.
    Rafferty, Mark A.
    Moseley, Douglas J.
    Jaffray, David A.
    Irish, Jonathan C.
    JOURNAL OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2008, 37 (01): : 81 - 90
  • [23] C-Arm Cone Beam Computed Tomography Guidance for Radiofrequency Ablation in Hepatocellular Carcinoma
    Kato, Keizo
    Abe, Hiroshi
    Ika, Makiko
    Yonezawa, Takeshi
    Sato, Yoshiyuki
    Hanawa, Noriko
    Shimizu, Shohei
    Endo, Shinji
    Matsuo, Ryota
    Tsubota, Akihito
    ONCOLOGY, 2017, 92 (03) : 142 - 152
  • [24] The Impact of the Use of C-Arm Cone-Beam CT During Chemoembolization for Hepatocellular Carcinoma
    Abdelsalam, Mohamed E.
    Figueira, Tomas M. A.
    Ensor, Joe
    Tam, Alda L.
    Avritscher, Rony
    Kaseb, Ahmed
    Gupta, Sanjay
    CURRENT MEDICAL IMAGING, 2022, 18 (04) : 372 - 380
  • [25] 2D–3D radiograph to cone-beam computed tomography (CBCT) registration for C-arm image-guided robotic surgery
    Wen Pei Liu
    Yoshito Otake
    Mahdi Azizian
    Oliver J. Wagner
    Jonathan M. Sorger
    Mehran Armand
    Russell H. Taylor
    International Journal of Computer Assisted Radiology and Surgery, 2015, 10 : 1239 - 1252
  • [26] Cone-beam computed tomography in the treatment of distal radius fractures
    Wieschollek, Stefanie
    Knie, Careen
    Megerle, Kai
    HANDCHIRURGIE MIKROCHIRURGIE PLASTISCHE CHIRURGIE, 2023, 55 (03) : 174 - 185
  • [27] Diagnostic efficacy of cone-beam computed tomography for mandibular fractures
    Kaeppler, Gabriele
    Cornelius, Carl-Peter
    Ehrenfeld, Michael
    Mast, Gerson
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2013, 116 (01): : 98 - 104
  • [28] Intraoperative Cone-Beam Computed Tomography in Oral and Maxillofacial Surgery Using a C-Arm Prototype: First Clinical Experiences After Treatment of Zygomaticomaxillary Complex Fractures
    Pohlenz, Philipp
    Blake, Felix
    Blessmann, Marco
    Smeets, Ralf
    Habermann, Christian
    Begemann, Philipp
    Schmelzle, Rainer
    Heiland, Max
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2009, 67 (03) : 515 - 521
  • [29] Applications of cone-beam computed tomography in fractures of the maxillofacial complex
    Shintaku, Werner H.
    Venturin, Jaqueline S.
    Azevedo, Bruno
    Noujeim, Marcel
    DENTAL TRAUMATOLOGY, 2009, 25 (04) : 358 - 366
  • [30] Comparison of Cone-Beam Computed Tomography and Multislice Computed Tomography in the Assessment of Extremity Fractures
    Dubreuil, Thibaut
    Mouly, Jerome
    Ltaief-Boudrigua, Aicha
    Martinon, Amanda
    Tilhet-Coartet, Stephane
    Tazarourte, Karim
    Pialat, Jean-Baptiste
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (03) : 372 - 378