摘要
Purpose Tension band wiring (TBW) is the most widely accepted method for patella fracture fixation. The purpose of our study was to compare the biomechanical efficacy of a novel cable construct to TBW for the fixation of transverse patella fractures. The tensioned cable construct was hypothesized to have less fracture gapping after cyclic flexion-extension loading and greater ultimate load to failure as compared to TBW. Methods Transverse patellar osteotomies (AO/OTA 34C1.1) were performed on nine pairs of fresh-frozen human cadaveric whole legs (mean age 82.2 years, range 71-101). Treatment with TBW or tensioned cable construct was randomized within each specimen pair. Fracture site displacement was measured after 5000 flexion-extension cycles from 0 degrees to 90 degrees at 0.5 Hz. In load to failure testing, the knee was fixed at 45 degrees of flexion and the quadriceps tendon was pulled proximally at 0.5 mm/sec until patella fixation failure. Comparisons were made using paired t-tests with alpha values of 0.05. Results Eight paired specimens completed the cyclic loading. The tensioned cable construct had significantly less fracture gapping than TBW (2.9 vs 10.9 mm; p = 0.020). Seven paired limbs underwent load to failure testing, which revealed no significant difference between the tensioned cable construct and TBW (1551.6 N vs 1664.0 N; p = 0.26). Conclusion In this study of transverse patella fracture fixation, a tensioned cable construct demonstrated significantly less fracture gapping compared to TBW in response to cyclic loading with no significant difference in load at failure.
引用
收藏
页码:1573 / 1580
页数:8
相关论文
共 50 条
  • [21] ORIF Patella Fracture With a Tension Band Construct
    Blum, Laura
    Hake, Mark
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2017, 31 : S8 - S9
  • [22] Fracture of the inferior pole of the patella: tension band wiring versus transosseous reattachment
    Chih-Hsun Chang
    Hao-Chun Chuang
    Wei-Ren Su
    Fa-Chuan Kuan
    Chih-Kai Hong
    Kai-Lan Hsu
    Journal of Orthopaedic Surgery and Research, 16
  • [23] LOWER POLE PATELLA FRACTURE: A COMBINATION OF CANCELLOUS SCREW FIXATION AND TENSION BAND WIRING
    Veeranna, H. D.
    Chaitanya, P. R.
    Sreekanth, R.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2014, 3 (31): : 8575 - 8578
  • [24] Horizontal Versus Vertical Orientation of the Loop for Tension Band Wiring of Transverse Patella Fractures
    Lee, Sang Ki
    Hwang, Yoon Sub
    Choy, Won Sik
    ORTHOPEDICS, 2014, 37 (03) : E265 - E271
  • [25] Cannulated compression screws with cable technique leads to a dramatic reduction in patella fracture fixation complications compared to tension band wiring
    Poh, Jane Wenjin
    Li, Zongxian
    Koh, Don Thong Siang
    Tay, Kenny Xian Khing
    Goh, Seo Kiat
    Woo, Yew Lok
    Xia, Zhan
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (09) : 4333 - 4341
  • [26] Post Operative Functional Outcome of Modified Tension Band Wiring in Patients with Transverse Fracture of Patella
    Qureshi, Attique Ur Rehman
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2013, 7 (01): : 197 - 199
  • [27] Medial malleolus fractures: A biomechanical comparison of tension band wiring fixation methods
    Uygur, Esat
    Poyanli, Oguz
    Mutlu, Ibrahim
    Celik, Talip
    Akpinar, Fuat
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2018, 104 (08) : 1259 - 1263
  • [28] Biomechanical comparison of continuous compression implants versus tension band fixation for transverse olecranon fractures
    Moon, Morgan
    Schweser, Kyle
    Bezold, Will
    Cook, James L.
    JOURNAL OF ORTHOPAEDICS, 2022, 34 : 316 - 321
  • [29] New Intramedullary Locking Nail for Olecranon Fracture Fixation-An In Vitro Biomechanical Comparison With Tension Band Wiring
    Nowak, Tobias E.
    Burkhart, Klaus J.
    Mueller, Lars P.
    Mattyasovszky, Stefan G.
    Andres, Torsten
    Sternstein, Werner
    Rommens, Pol M.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2010, 69 (05): : E56 - E61
  • [30] Internal Fixation of Transverse Patella Fractures Using Cannulated Cancellous Screws with Anterior Tension Band Wiring
    Khan, I
    Dar, M. Y.
    Rashid, S.
    Butt, M. F.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2016, 10 (02) : 21 - 26