Anatomical information of the lenticulostriate arteries on high-resolution 3D-TOF MRA at 3 T: comparison with 3D-DSA

被引:0
|
作者
Takahashi, Sanae [1 ]
Gomyo, Miho [2 ]
Tsuchiya, Kazuhiro [3 ]
Yoshioka, Tatsuya [4 ]
Kobayashi, Kuninori [1 ]
Nakanishi, Akihito [4 ]
Yokoyama, Kenichi [2 ]
机构
[1] Kyorin Univ, Fac Hlth Sci, Dept Med Radiol Technol, 5-4-1 Shimorenjaku, Mitaka, Tokyo 1818612, Japan
[2] Kyorin Univ, Fac Med, Dept Radiol, 6-20-2 Shinkawa, Mitaka, Tokyo 1818611, Japan
[3] JR Tokyo Gen Hosp, Dept Radiol, Tokyo, Japan
[4] Kyorin Univ Hosp, Sect Radiol, Tokyo, Japan
关键词
Lateral lenticulostriate artery (LSA); High resolution; Magnetic resonance imaging (MRI); Magnetic resonance angiography (MRA); Digital subtraction angiography (DSA); ANGIOGRAPHY;
D O I
10.1007/s00276-023-03232-6
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
Purpose As the lenticulostriate arteries (LSAs) perfuse neurologically important areas, it is necessary to accurately assess the origin and number of the LSAs before surgery. Although three-dimensional time-of-flight MR angiography (3D-TOF MRA) is a non-invasive procedure, it requires high-resolution (HR) images to depict the LSAs with a small diameter. Therefore, we performed 3D-TOF MRA with the maximum HR (HR-MRA) using a 3 T scanner to examine whether a good depiction of the LSAs, equivalent to that of digital subtraction angiography (DSA), could be obtained. Methods Our study group comprised 16 consecutive patients who underwent HR-MRA and 3D-DSA. In both studies, we evaluated the localization of the origin from M1, M2, or A1 segments, their number of stems, and depiction. Results There was no significant difference in the visualization of the LSAs between HR-MRA and 3D-DSA (P values; M1, M2, and A1 = 0.39, 0.69, and 0.69, respectively), and both the number of stems and the localization of the origin of the LSAs corresponded between the two examinations. Conclusion HR-MRA at 3 T can depict the LSA well. It reveals the number of the LSA stems and the LSA origin comparatively with DSA.
引用
收藏
页码:1287 / 1293
页数:7
相关论文
共 50 条
  • [41] Evaluation of intracranial aneurysm: Comparison between ZTE-MRA and 3D-TOF-MRA
    Lyu, J.
    Sha, L.
    Qi, X.
    Chen, Z.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2022, 20 (03): : 723 - 725
  • [42] High-resolution IBIS observations and comparison with 3D simulations
    Cauzzi, G.
    Ramos, A. Asensio
    Reardon, K.
    Janssen, K.
    SOLAR MHD THEORY AND OBSERVATIONS: A HIGH SPATIAL RESOLUTION PERSPECTIVE, IN HONOR OF ROBERT F. STEIN, 2006, 354 : 26 - +
  • [43] Evaluation of chronic carotid artery occlusion by non-contrast 3D-MERGE MR vessel wall imaging: comparison with 3D-TOF-MRA, contrast-enhanced MRA, and DSA
    Jin Zhang
    Shenghao Ding
    Huilin Zhao
    Beibei Sun
    Xiao Li
    Yan Zhou
    Jieqing Wan
    Andrew J. Degnan
    Jianrong Xu
    Chengcheng Zhu
    European Radiology, 2020, 30 : 5805 - 5814
  • [44] 3D-TOF MRA对颅内血管性病变的诊断价值
    王化敏
    程若勤
    金红花
    时小刚
    吴予晨
    放射学实践, 1998, (02) : 63 - 65
  • [45] 应用磁共振3D-TOF MRA成像观察脑膜瘤供血特征
    郑晔
    李德刚
    杨蔚
    陈兵
    王晓东
    金国宏
    宁夏医学杂志, 2010, 32 (05) : 414 - 415
  • [46] 单侧颈内动脉闭塞患者Willis环3D-TOF MRA检出的评价
    逄利博
    杨本强
    段阳
    医学影像学杂志, 2017, 27 (11) : 2061 - 2064
  • [47] Evaluating recanalization of relevant lenticulostriate arteries in acute ischemic stroke using high-resolution MRA at 7T
    Suzuki, Takafumi
    Natori, Tatsunori
    Sasaki, Makoto
    Miyazawa, Haruna
    Narumi, Shinsuke
    Ito, Kohei
    Kamada, Asami
    Yoshida, Makiko
    Tsuda, Keisuke
    Yoshioka, Kunihiro
    Terayama, Yasuo
    INTERNATIONAL JOURNAL OF STROKE, 2021, 16 (09) : 1039 - 1046
  • [48] 高场强MRI常规序列及3D-TOF MRA诊断烟雾病的价值
    罗应斌
    唐蕾
    余晖
    重庆医学, 2014, 43 (13) : 1581 - 1583
  • [49] Role of 3D-TOF magnetic resonance angiography for intracranial meningioma
    Abe, T
    Matsumoto, K
    Hanakawa, K
    Homma, H
    Kawamura, N
    Ikeda, H
    Horichi, Y
    Hayashi, T
    JOURNAL OF CLINICAL NEUROSCIENCE, 1998, 5 (04) : 387 - 389
  • [50] Evaluation of chronic carotid artery occlusion by non-contrast 3D-MERGE MR vessel wall imaging: comparison with 3D-TOF-MRA, contrast-enhanced MRA, and DSA
    Zhang, Jin
    Ding, Shenghao
    Zhao, Huilin
    Sun, Beibei
    Li, Xiao
    Zhou, Yan
    Wan, Jieqing
    Degnan, Andrew J.
    Xu, Jianrong
    Zhu, Chengcheng
    EUROPEAN RADIOLOGY, 2020, 30 (11) : 5805 - 5814