Comparison of the International Normalized Ratio Between a Point-of-Care Test and a Conventional Laboratory Test: the Latter Performs Better in Assessing Warfarin-induced Changes in Coagulation Factors

被引:5
|
作者
Kim, Ye-Seul
Choi, Jae-Woong [2 ]
Song, Sang Hoon
Hwang, Ho Young [1 ]
Sohn, Suk Ho [1 ]
Kim, Ji Seong [1 ]
Kang, Yoonjin [1 ]
Gu, Ja-Yoon [2 ]
Kim, Kyung Hwan [1 ,6 ]
Kim, Hyun Kyung [1 ,3 ,4 ,5 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Lab Med, Seoul, South Korea
[2] Seoul Natl Univ Hosp, Dept Thorac & Cardiovasc Surg, Seoul, South Korea
[3] Seoul Natl Univ, Seoul Natl Univ Hosp, Coll Med, Canc Res Inst, Seoul, South Korea
[4] Seoul Natl Univ, Dept Lab Med, Coll Med, 101 Daehak Ro, Seoul 03080, South Korea
[5] Seoul Natl Univ, Canc Res Inst, Coll Med, 101 Daehak Ro, Seoul 03080, South Korea
[6] Seoul Natl Univ Hosp, Dept Thorac & Cardiovasc Surg, 101 Daehak Ro, Seoul 03080, South Korea
基金
新加坡国家研究基金会;
关键词
International normalized ratio; Point-of-care testing; Warfarin; Blood coagulation factors; Comparative study; Cardiac surgery; COAGUCHEK XS; MANAGEMENT; INR;
D O I
10.3343/alm.2023.43.4.337
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Point-of-care testing (POCT) coagulometers are increasingly used for moni-toring warfarin therapy. However, in high international normalized ratio (INR) ranges, significant discrepancy in the INR between POCT and conventional laboratory tests occurs. We compared the INR of POCT (CoaguChek XS Plus; Roche Diagnostics, Mannheim, Germany) with that of a conventional laboratory test (ACL TOP 750; Instrumentation Laboratory SpA, Milan, Italy) and explored possible reasons for discrepancy. Methods: Paired POCT and conventional laboratory test INRs were analyzed in 400 samples from 126 patients undergoing warfarin therapy after cardiac surgery. Coagulation factor and thrombin generation tests were compared using the Mann-Whitney U test. Correlations between coagulation factors and INRs were determined using Pearson correlation coefficients. Results: The mean difference in the INR between the tests increased at high INR ranges. Endogenous thrombin potential levels were decreased at INR <2.0 for CoaguChek XS Plus and 2.0< INR <3.0 for ACL TOP 750 compared with those at INR <2.0 for both tests, indicating a better performance of ACL TOP 750 in assessing thrombin changes. The correlation coefficients of coagulation factors were stronger for ACL TOP 750 INR than for CoaguChek XS Plus INR. Vitamin K-dependent coagulation factors were found to contribute to the INR discrepancy. Conclusions: Decreases in vitamin K-dependent coagulation and anticoagulation factors can explain the significant discrepancy between the two tests in high INR ranges. Since conventional laboratory test INR values are more reliable than POCT INR values, a confir-matory conventional laboratory test is required for high INR ranges.
引用
收藏
页码:337 / 344
页数:8
相关论文
共 19 条
  • [11] An analysis of discrepancy between point-of-care and central laboratory international normalized ratio testing in ED patients with cerebrovascular disease
    Nanduri, Sunanda
    Tayal, Ashis H.
    Hegde, Gajanan G.
    Shang, Jennifer
    Venkat, Arvind
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2012, 30 (09): : 2025 - 2029
  • [12] Comparison of international normalized ratio determined by point-of-care to standard laboratory testing before and after reversal of heparin in cardiac surgery
    Fabbro, Michael, II
    Abalo, Miguel
    Fermin, Lilibeth
    Andrews, David M.
    Patel, Prakash A.
    BLOOD COAGULATION & FIBRINOLYSIS, 2020, 31 (02) : 140 - 144
  • [13] Evaluation of the i-STAT point-of-care capillary whole blood prothrombin time and international normalized ratio: Comparison to the Tcoag MDAII coagulation analyzer in the central laboratory
    Pena, J. A.
    Lewandrowski, K. B.
    Lewandrowski, E. L.
    Gregory, K.
    Baron, J. M.
    Van Cott, E. M.
    CLINICA CHIMICA ACTA, 2012, 413 (11-12) : 955 - 959
  • [14] Comparison between a new point-of-care HbA1c test and a routine laboratory method
    Relker, L.
    Luppa, P. B.
    CLINICA CHIMICA ACTA, 2024, 558
  • [15] Comparison between point-of-care dermatophyte test medium and mycology laboratory culture for diagnosis of dermatophytosis in dogs and cats
    Kaufmann, Ronnie
    Blum, Shlomo E.
    Elad, Daniel
    Zur, Gila
    VETERINARY DERMATOLOGY, 2016, 27 (04) : 284 - E68
  • [16] A Comparison of International Normalized Ratio (INR) Determined by Point-of-Care to Standard Laboratory Testing Before Mohs Micrographic Surgery: A Prospective, Single-Center Study
    Moody, Rylee
    Tinker, Daniel
    Behshad, Ramona
    DERMATOLOGIC SURGERY, 2023, 49 (10) : 967 - 969
  • [17] Comparison of point-of-care testing (POCT): i-STAT® international normalized ratio (INR) vs reference laboratory INR in pediatric patients undergoing major surgery
    Spielmann, Nelly
    Mauch, Jacqueline Y.
    Madjdpour, Caveh
    Schmugge, Markus
    Albisetti, Manuela
    Weiss, Markus
    Haas, Thorsten
    PEDIATRIC ANESTHESIA, 2011, 21 (10) : 1041 - 1045
  • [18] Correlation between platelet response units measured with a point-of-care test and ADP-induced platelet aggregation assessed with conventional optical aggregometry
    Von Beckerath, N.
    Pogatsa-Murray, G.
    Wieczorek, A.
    Schomig, A.
    Kastrati, A.
    EUROPEAN HEART JOURNAL, 2005, 26 : 479 - 479
  • [19] European Concerted Action on Anticoagulation. Correction of displayed international normalized ratio on two point-of-care test whole-blood prothrombin time monitors (CoaguChek Mini and TAS PT-NC) by independent international sensitivity index calibration
    Poller, L
    Keown, M
    Chauhan, N
    van den Besselaar, AMHP
    Tripodi, A
    Shiach, C
    Jespersen, J
    BRITISH JOURNAL OF HAEMATOLOGY, 2003, 122 (06) : 944 - 949