Evaluation of deep-learning image reconstruction for chest CT examinations at two different dose levels

被引:6
|
作者
Svalkvist, Angelica [1 ,2 ,5 ]
Fagman, Erika [3 ,4 ]
Vikgren, Jenny [3 ,4 ]
Ku, Sara [3 ]
Diniz, Micael Oliveira [3 ,4 ]
Norrlund, Rauni Rossi [3 ,4 ]
Johnsson, Ase A. [3 ,4 ]
机构
[1] Sahlgrens Univ Hosp, Dept Med Phys & Biomed Engn, Gothenburg, Sweden
[2] Univ Gothenburg, Inst Clin Sci, Dept Med Radiat Sci, Sahlgrenska Acad, Gothenburg, Sweden
[3] Sahlgrens Univ Hosp, Dept Radiol, Gothenburg, Sweden
[4] Univ Gothenburg, Inst Clin Sci, Sahlgrenska Acad, Dept Radiol, Gothenburg, Sweden
[5] Sahlgrens Univ Hosp, Dept Med Phys & Biomed Engn, Gula straket 2B,plan 0, SE-41345 Gothenburg, Sweden
来源
关键词
chest; computed tomography; deep-learning image reconstruction; post-processing; ultra-low dose; NODULE DETECTION; VGC ANALYZER; SOFTWARE; QUALITY; TEXTURE;
D O I
10.1002/acm2.13871
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AimsThe aims of the present study were to, for both a full-dose protocol and an ultra-low dose (ULD) protocol, compare the image quality of chest CT examinations reconstructed using TrueFidelity (Standard kernel) with corresponding examinations reconstructed using ASIR-V (Lung kernel) and to evaluate if post-processing using an edge-enhancement filter affects the noise level, spatial resolution and subjective image quality of clinical images reconstructed using TrueFidelity. MethodsA total of 25 patients were examined with both a full-dose protocol and an ULD protocol using a GE Revolution APEX CT system (GE Healthcare, Milwaukee, USA). Three different reconstructions were included in the study: ASIR-V 40%, DLIR-H, and DLIR-H with additional post-processing using an edge-enhancement filter (DLIR-H + E2). Five observers assessed image quality in two separate visual grading characteristics (VGC) studies. The results from the studies were statistically analyzed using VGC Analyzer. Quantitative evaluations were based on determination of two-dimensional power spectrum (PS), contrast-to-noise ratio (CNR), and spatial resolution in the reconstructed patient images. ResultsFor both protocols, examinations reconstructed using TrueFidelity were statistically rated equal to or significantly higher than examinations reconstructed using ASIR-V 40%, but the ULD protocol benefitted more from TrueFidelity. In general, no differences in observer ratings were found between DLIR-H and DLIR-H + E2. For the three investigated image reconstruction methods, ASIR-V 40% showed highest noise and spatial resolution and DLIR-H the lowest, while the CNR was highest in DLIR-H and lowest in ASIR-V 40%. ConclusionThe use of TrueFidelity for image reconstruction resulted in higher ratings on subjective image quality than ASIR-V 40%. The benefit of using TrueFidelity was larger for the ULD protocol than for the full-dose protocol. Post-processing of the TrueFidelity images using an edge-enhancement filter resulted in higher image noise and spatial resolution but did not affect the subjective image quality.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Low-Dose CT Image Reconstruction With a Deep Learning Prior
    Park, Hyoung Suk
    Kim, Kyungsang
    Jeon, Kiwan
    IEEE ACCESS, 2020, 8 : 158647 - 158655
  • [22] A Deep-Learning Based Lower-Dose CT Simulation Technique in Image Domain
    Gong, H.
    Leng, S.
    McCollough, C.
    Yu, L.
    MEDICAL PHYSICS, 2019, 46 (06) : E189 - E189
  • [23] Comparison of image quality of two versions of deep-learning image reconstruction algorithm on a rapid kV-switching CT: a phantom study
    Dabli, Djamel
    Loisy, Maeliss
    Frandon, Julien
    de Oliveira, Fabien
    Meerun, Azhar Mohamad
    Guiu, Boris
    Beregi, Jean-Paul
    Greffier, Joel
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2023, 7 (01)
  • [24] Comparison of image quality of two versions of deep-learning image reconstruction algorithm on a rapid kV-switching CT: a phantom study
    Djamel Dabli
    Maeliss Loisy
    Julien Frandon
    Fabien de Oliveira
    Azhar Mohamad Meerun
    Boris Guiu
    Jean-Paul Beregi
    Joël Greffier
    European Radiology Experimental, 7
  • [25] Deep-learning image-reconstruction algorithm for dual-energy CT angiography with reduced iodine dose: preliminary results
    Noda, Y.
    Nakamura, F.
    Kawamura, T.
    Kawai, N.
    Kaga, T.
    Miyoshi, T.
    Kato, H.
    Hyodo, F.
    Matsuo, M.
    CLINICAL RADIOLOGY, 2022, 77 (02) : E138 - E146
  • [26] Improving the image quality of pediatric chest CT angiography with low radiation dose and contrast volume using deep learning image reconstruction
    Sun, Jihang
    Li, Haoyan
    Li, Jianying
    Yu, Tong
    Li, Michelle
    Zhou, Zuofu
    Peng, Yun
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2021, 11 (07) : 3051 - 3058
  • [27] ?Image quality evaluation of the Precise image CT deep learning reconstruction algorithm compared to Filtered Back-projection and iDose4: a phantom study at different dose levels?
    Barca, Patrizio
    Domenichelli, Sara
    Golfieri, Rita
    Pierotti, Luisa
    Spagnoli, Lorenzo
    Tomasi, Silvia
    Strigari, Lidia
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 106
  • [28] Commentary On: Image Quality Evaluation in Dual Energy CT of the Chest, Abdomen and Pelvis in Obese Patients with Deep Learning Image Reconstruction
    Jensen, Corey T.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2022, 46 (04) : 612 - 613
  • [29] Image Quality Evaluation in Dual-Energy CT of the Chest, Abdomen, and Pelvis in Obese Patients With Deep Learning Image Reconstruction
    Fair, Eric
    Profio, Mark
    Kulkarni, Naveen
    Laviolette, Peter S.
    Barnes, Bret
    Bobholz, Samuel
    Levenhagen, Maureen
    Ausman, Robin
    Griffin, Michael O.
    Duvnjak, Petar
    Zorn, Adam P.
    Foley, W. Dennis
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2022, 46 (04) : 604 - 611
  • [30] Comparison of two versions of a deep learning image reconstruction algorithm on CT image quality and dose reduction: A phantom study
    Greffier, Joel
    Dabli, Djamel
    Frandon, Julien
    Hamard, Aymeric
    Belaouni, Asmaa
    Akessoul, Philippe
    Fuamba, Yannick
    Le Roy, Julien
    Guiu, Boris
    Beregi, Jean-Paul
    MEDICAL PHYSICS, 2021, 48 (10) : 5743 - 5755