Seismic performance of elliptical FRP-concrete-steel tubular columns under combined axial load and reversed lateral load

被引:24
|
作者
Zhang, Bing [1 ]
Peng, Yutao [1 ]
Gao, Yuhang [1 ]
Wang, Yanlei [2 ]
Chen, Guipeng [2 ]
Zhou, Chong [1 ]
Zhang, Ningyuan [3 ]
机构
[1] Harbin Inst Technol Shenzhen, Sch Civil & Environm Engn, Shenzhen 518055, Peoples R China
[2] Dalian Univ Technol, Sch Civil Engn, State Key Lab Coastal & Offshore Engn, Dalian 116024, Peoples R China
[3] Nanjing Tech Univ, Coll Civil Engn, Nanjing 211816, Peoples R China
基金
中国国家自然科学基金;
关键词
FRP; Elliptical cross-section; Tubular column; Reversed lateral load; Hysteretic behavior; STRESS-STRAIN MODEL; BEHAVIOR; COMPRESSION; BRIDGE; TESTS;
D O I
10.1016/j.engstruct.2023.116135
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
By combining FRP composites with both steel and concrete, double-skin tubular columns (i.e., DSTCs) with a hollow core are a novel structural member to be used as bridge piers or other columns in harsh environments. Up to now, DSTCs with circular or square sections (i.e., C-DSTCs or S-DSTCs) have been investigated extensively, while DSTCs with an elliptical section (i.e., E-DSTCs) are rarely studied. E-DSTCs are composed of two concentric elliptical tubes (i.e., the external FRP tube and the internal steel tube) and a sandwiched concrete layer. E-DSTCs can be designed with two distinct bending stiffness with respect to the two axes of symmetry. Similar to C-DSTCs, E-DSTCs have an FRP tube with a continuously curved circumference, thus effectively confining the concrete layer. To extend the existing research, this paper tested six large E-DSTCs under combined axial load and reversed lateral load to investigate the effect of elliptical aspect ratio. The testing parameters also included the direction of reversed lateral load and the FRP thickness. Experimental results showed that, E-DSTCs performed with rounded hysteresis loops and remarkable ductility even for the specimen with a large aspect ratio (i.e., for the elliptical aspect ratio from 1.0 to 2.0, the ductility index increased monotonically from 6.50 to 7.75); a thicker FRP tube led to marginally higher peak load but noticeably better ductility (i.e., the specimen with 2.10 mm FRP had an average peak load of 77.65 kN and a ductility index of 7.14, while the corresponding specimen with 1.05 mm had an average peak load of 77.35 kN and a ductility index of 6.29); as expected, the specimen bending around its strong axis had much superior ductility than the companion specimen bending around its weak axis. A numerical column model was established based on OpenSees to simulate the hysteretic behavior of E-DSTCs, and a parametric study was conducted to assess the influences of FRP thickness, concrete strength, axial load ratio, steel tube thickness, void ratio as well as elliptical aspect ratio. In practical engineering design, it was recommended that: (a) the elliptical aspect ratio as well as other key parameters (e.g., the FRP thickness, the steel tube thickness, the area void ratio) should be optimized based on specific loading conditions; (b) to make more effective usage of FRP composites, the FRP tube thickness should be optimized for different height regions of the column according to the moment gradient caused by the reversed lateral load.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] Axial compression behavior of double-skin FRP-concrete-steel tubular columns: Experimental and analytical investigations
    Zakir, Mohammad
    Sahoo, Dipti Ranjan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2023, 211
  • [32] Load-Strain Model for Steel-Concrete-FRP-Concrete Columns in Axial Compression
    Cheng, Shi
    Feng, Peng
    Bai, Yu
    Ye, Lie Ping
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2016, 20 (05)
  • [33] Performance of reinforced concrete columns under bi-axial lateral force/displacement and axial load
    Shirmohammadi, Fatemeh
    Esmaeily, Asad
    ENGINEERING STRUCTURES, 2015, 99 : 63 - 77
  • [34] INFLUENCE OF CONCRETE AND FRP TUBES PROPERTIES ON BEHAVIOR OF FRP-CONCRETE-STEEL DOUBLE-SKIN TUBULAR COLUMNS SUBJECTED TO CYCLIC AXIAL COMPRESSION
    Fanggi, Butje Alfonsius Louk
    Ozbakkaloglu, Togay
    PROCEEDINGS OF THE THIRTEENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOLS 1 AND II, 2014, : 572 - 580
  • [35] Behavior of hybrid FRP-concrete-steel double-skin tubular columns subjected to cyclic axial compression
    Yu, T.
    Zhang, B.
    Cao, Y. B.
    Teng, J. G.
    THIN-WALLED STRUCTURES, 2012, 61 : 196 - 203
  • [36] Behavior of Large-Scale Hybrid FRP-Concrete-Steel Multitube Concrete Columns under Axial Compression
    Chan, C. W.
    Yu, T.
    Bai, Y. L.
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2021, 25 (01)
  • [37] An Investigation of Compression Bearing Capacity of Concrete-Filled Rectangular Stainless Steel Tubular Columns under Axial Load and Eccentric Axial Load
    Cao, Bing
    Zhu, Longfei
    Jiang, Xintong
    Wang, Changsheng
    SUSTAINABILITY, 2022, 14 (14)
  • [38] Seismic Behavior of Hollow-Core FRP-Concrete-Steel Bridge Columns
    Abdelkarim, Omar I.
    Gheni, Ahmed
    Anumolu, Sujith
    ElGawady, Mohamed A.
    Structures Congress 2015, 2015, : 585 - 596
  • [39] Analysis oriented model for hybrid filament wound FRP-concrete-steel double skin tubular columns (DSTC) under axial compression
    Bhat, Pronnoy
    Jamatia, Rimen
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 223
  • [40] Relative Performance of FRP-Concrete-Steel Double Skin Tubular Columns versus Solid and Hollow Concrete-filled FRP Tubes
    Fanggi, Butje Alfonsius Louk
    Ozbakkloglu, Togay
    ADVANCES IN CIVIL AND STRUCTURAL ENGINEERING III, PTS 1-4, 2014, 501-504 : 3 - 7