Combined GPR and Self-Potential Techniques for Monitoring Steel Rebar Corrosion in Reinforced Concrete Structures: A Laboratory Study

被引:2
|
作者
Fornasari, Giacomo [1 ,2 ]
Capozzoli, Luigi [2 ]
Rizzo, Enzo [1 ,2 ]
机构
[1] Univ Ferrara, Dipartimento Fis & Sci Terra, I-44121 Ferrara, FE, Italy
[2] CNR, Inst Methodol Environm Anal, I-85050 Tito, PZ, Italy
关键词
rebar corrosion monitoring; reinforced concrete; non-destructive testing (NDT); ground-penetrating radar (GPR); self-potential (SP); structural damage; GROUND-PENETRATING RADAR;
D O I
10.3390/rs15082206
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Steel rebar corrosion is one of the main causes of the deterioration of engineering reinforced structures. Steel rebar in concrete is normally in a non-corroding, passive condition, but these conditions are not always achieved in practice, due to which corrosion of rebars takes place. This degradation has physical consequences, such as decreased ultimate strength and serviceability of engineering concrete structures. This work describes a laboratory test where GPR and SP geophysical techniques were used to detect and monitor the corrosion phenomena. The laboratory tests have been performed with several reinforced concrete samples. The concrete samples were partially submerged in water with a 5% sodium chloride (NaCl) solution. Therefore, an accelerated corrosion phenomenon has been produced by a direct current (DC) power supply along the rebar. The geophysical measurements were performed with a 2.0 GHz centre frequency GPR antenna along several parallel lines on the samples, always being the radar line perpendicular to the rebar axis. The GPR A-scan amplitude signals were elaborated with the Hilbert Transform approach, observing the envelope variations due to the progress of the steel rebar corrosion in each concrete sample. Moreover, Self-Potential acquisitions were carried out on the surface of the concrete sample at the beginning and end of the experiments. Each technique provided specific information, but a data integration method used in the operating system will further improve the overall quality of diagnosis. The collected data were used for an integrated detection approach useful to observe the corrosion evolution along the reinforcement bar. These first laboratory results highlight how the GPR should give a quantitative contribution to the deterioration of reinforced concrete structure.
引用
收藏
页数:18
相关论文
共 35 条
  • [31] Fundamental study of the potential application of steel fiber reinforced concrete to enhance the impact resistance of nuclear power plant structures
    Cho, Hyun-Woo
    Moon, Jae-Heum
    Lee, Jang-Hwa
    APPLIED MATERIALS AND TECHNOLOGIES FOR MODERN MANUFACTURING, PTS 1-4, 2013, 423-426 : 1211 - 1216
  • [32] Stray current-induced corrosion in cathodic protection installations of steel-reinforced concrete structures: FEM study of the critical parameters
    Eichler, Thorsten
    Isecke, Bernd
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2020, 71 (05): : 738 - 748
  • [33] A Laboratory Study on the Flexural and Shear Behavior of RC Beams Retrofitted with Steel Fiber-Reinforced Self-compacting Concrete Jacket
    Rahmani, Iraj
    Maleki, Ahmad
    Lotfollahi-Yaghin, Mohammad Ali
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF CIVIL ENGINEERING, 2021, 45 (04) : 2359 - 2375
  • [34] A Laboratory Study on the Flexural and Shear Behavior of RC Beams Retrofitted with Steel Fiber-Reinforced Self-compacting Concrete Jacket
    Iraj Rahmani
    Ahmad Maleki
    Mohammad Ali Lotfollahi-Yaghin
    Iranian Journal of Science and Technology, Transactions of Civil Engineering, 2021, 45 : 2359 - 2375
  • [35] Study of Combined Multi-Point Constraint Multi-Scale Modeling Strategy for Ultra-High-Performance Steel Fiber-Reinforced Concrete Structures
    Li, Zuohua
    Peng, Zhihan
    Teng, Jun
    MATERIALS, 2020, 13 (23) : 1 - 19