Diagnostic accuracy of clinical tests to rule out elbow fracture: a systematic review

被引:7
|
作者
Breda, Giorgio [1 ,2 ]
De Marco, Gianluca [1 ]
Cesaraccio, Pierfranco
Pillastrini, Paolo [1 ]
机构
[1] Alma Mater Studiorum Univ Bologna, Dept Biomed & Neuromotor Sci DIBINEM, Bologna, Italy
[2] Univ Padua, Dept Neurosci DNS, Padua, Italy
来源
CLINICS IN SHOULDER AND ELBOW | 2023年 / 26卷 / 02期
关键词
Physical examination; Sensitivity and specificity; Elbow joint; Fractures bone; OTTAWA ANKLE RULES; COMPUTED-TOMOGRAPHY; SIGNIFICANT INJURY; POINT TENDERNESS; DECISION RULES; ACTIVE RANGE; EXTENSION; TRAUMA; MOTION; EPIDEMIOLOGY;
D O I
10.5397/cise.2022.00948
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Elbow traumas represent a relatively common condition in clinical practice. However, there is a lack of evidence regarding the most accurate tests for screening these potentially serious conditions and excluding elbow fractures. The purpose of this investigation was to analyze the literature concerning the diagnostic accuracy of clinical tests for the detection or exclusion of suspected elbow fractures. A systematic review was performed using the Preferred Reporting Items for a Systematic Review and Meta-analysis of Diagnostic Test Accuracy Studies (PRISMA-DTA) guidelines. Literature databases including PubMed, Cumulative Index to Nursing and Allied Health Literature, Diagnostic Test Accuracy, Cochrane Library, the Web of Science, and ScienceDirect were searched for diagnostic accuracy studies of subjects with suspected traumatic elbow fracture investigating clinical tests compared to imaging reference tests. The risk of bias in each study was assessed independently by two reviewers using the Quality Assessment of Diagnostic Accuracy Studies 2 checklist. Twelve studies (4,485 patients) were included. Three different types of index tests were extracted. In adults, these tests were very sensitive, with values up to 98.6% (95% confidence interval [CI], 95.0%-99.8%). The specificity was very variable, ranging from 24.0% (95% CI, 19.0%-30.0%) to 69.4% (95% CI, 57.3%-79.5%). The applicability of these tests was very high, while overall studies showed a medium risk of bias. Elbow full range of motion test, elbow extension test, and elbow extension and point tenderness test appear to be useful in the presence of a negative test to exclude fracture in a majority of cases. The specificity of all tests, however, does not allow us to draw useful conclusions because there was a great variability of results obtained.
引用
收藏
页码:182 / 190
页数:9
相关论文
共 50 条
  • [31] Diagnostic test accuracy of clinical tests and ultrasound for the detection of cam and pincer morphology - a systematic review
    Caliesch, R.
    Hilfiker, R.
    SWISS MEDICAL WEEKLY, 2019, : 21S - 21S
  • [32] Diagnostic Accuracy of Clinical Tests for Subacromial Impingement Syndrome: A Systematic Review and Meta-Analysis
    Alqunaee, Marwan
    Galvin, Rose
    Fahey, Tom
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2012, 93 (02): : 229 - 236
  • [33] Diagnostic Accuracy of Clinical Tests and Imaging Exams for Femoroacetabular Impingement: An Umbrella Review of Systematic Reviews
    Fernandes, Daniel A.
    Melo, Gilberto
    Contreras, Marcos E. K.
    Locks, Renato
    Chahla, Jorge
    Neves, Fabricio S.
    CLINICAL JOURNAL OF SPORT MEDICINE, 2022, 32 (06): : 635 - 647
  • [34] Diagnostic Performance of Prehospital Point-of-Care Troponin Tests to Rule Out Acute Myocardial Infarction: A Systematic Review
    Alghamdi, Abdulrhman
    Alotaibi, Ahmed
    Alharbi, Meshal
    Reynard, Charles
    Body, Richard
    PREHOSPITAL AND DISASTER MEDICINE, 2020, 35 (05) : 567 - 573
  • [35] Diagnostic Accuracy of Upper Cervical Spine Instability Tests: A Systematic Review
    Hutting, Nathan
    Scholten-Peeters, Gwendolijne G. M.
    Vijverman, Veerle
    Keesenberg, Martin D. M.
    Verhagen, Arianne P.
    PHYSICAL THERAPY, 2013, 93 (12): : 1686 - 1695
  • [36] The diagnostic accuracy and feasibility of paediatric visual field tests: A systematic review
    Riaz, Maria
    Ross, Nicole C.
    Mayer, D. Luisa
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2025,
  • [37] Accuracy of diagnostic tests for Cushing's syndrome: A systematic review and metaanalyses
    Elamin, Mohamed B.
    Murad, M. Hassan
    Mullan, Rebecca
    Erickson, Dana
    Harris, Katherine
    Nadeem, Sarah
    Ennis, Robert
    Erwin, Patricia J.
    Montori, Victor M.
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2008, 93 (05): : 1553 - 1562
  • [38] Diagnostic Test Accuracy of Genetic Tests in Diagnosing Psoriasis: A Systematic Review
    Mirghani, Hyder
    Alharfy, Abdulrahman Arshed N.
    Alanazi, Abeer Mohammed M.
    Aljohani, Jomanah Khalid M.
    Aljohani, Raghad Abdulrahman A.
    Albalawi, Raghad Hamdan A.
    Aljohani, Raneem Abdulrahman A.
    Albalawi, Danah Mohsen Alqasmi
    Albalawi, Rahaf Hamdan A.
    Mostafa, Mohamed, I
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (11)
  • [39] Diagnostic Accuracy of Tuning Fork Tests for Hearing Loss: A Systematic Review
    Kelly, Elizabeth A.
    Li, Bin
    Adams, Meredith E.
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2018, 159 (02) : 220 - 230
  • [40] Diagnostic Accuracy of Breath Tests to Detect Pulmonary Tuberculosis: A Systematic Review
    Chew, Natalie
    Yun, Sean
    See, Kay Choong
    LUNG, 2025, 203 (01)