Implant-retained overdenture delivery in 2 visits with a digital workflow

被引:1
|
作者
Jeong, Seung-Hoe [1 ]
Kim, Sunjai [1 ]
Seong, You Won [2 ]
Chang, Jae-Seung [1 ]
机构
[1] Yonsei Univ, Gangnam Severance Dent Hosp, Coll Dent, Dept Prosthodont, 211 Eonju Ro, Seoul 06273, South Korea
[2] Univ Tokyo, Grad Sch Publ Policy, Tokyo, Japan
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2023年 / 130卷 / 05期
基金
新加坡国家研究基金会;
关键词
DENTURES;
D O I
10.1016/j.prosdent.2021.12.023
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The conventional method of fabricating implant-retained overdentures involves multiple steps and patient visits. However, the duplication of existing complete dentures could decrease the number of visits and increase patient satisfaction. An existing maxillary implant-retained overdenture was replaced for a 78-year-old man; the existing implant-retained overdenture and his face were scanned at the first visit. The scanned intaglio image was inverted to obtain a virtual maxillary cast and used to fabricate the metal framework of the replacement implant-retained overdenture. Prefabricated artificial teeth were arranged on a 3-dimensional trial denture created from the scan data of the existing implant-retained overdenture. The replacement implantretained overdenture was fabricated on the metal framework by using the injection molding technique. By using these digital techniques, a stable and esthetic implant-retained overdenture was delivered in 2 visits. (J Prosthet Dent 2023;130:663-7)
引用
收藏
页码:663 / 667
页数:5
相关论文
共 50 条
  • [21] Dental implant-retained mandibular overdenture therapy: A clinical study of patients' response
    Pan, Yu-Hwa
    Yu, Ling-Ming
    Lin, Tai-Min
    JOURNAL OF DENTAL SCIENCES, 2014, 9 (02) : 118 - 124
  • [22] Comparison of stress distribution between complete denture and implant-retained overdenture-2D FEA
    Assuncao, W. G.
    Tabata, L. F.
    Barao, V. A. R.
    Rocha, E. P.
    JOURNAL OF ORAL REHABILITATION, 2008, 35 (10) : 766 - 774
  • [23] An alternative approach for the management of fractured implant abutment screws on a mandibular implant-retained overdenture: A clinical report
    Shah, Karnik
    Lee, Damian J.
    JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (04): : 402 - 405
  • [24] Reinforcement of Single Implant-Retained Mandibular Overdenture with a Cobalt-Chromium Framework before Implant Surgery
    do Amaral, Camilla Fraga
    Pinheiro, Mayara Abreu
    Matheus Rodrigues Garcia, Renata Cunha
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (07): : 844 - 848
  • [25] Implant-retained overdenture following hemiglossectomy: a 10-year clinical case report
    Taira, Y
    Sekine, J
    Sawase, T
    Atsuta, M
    JOURNAL OF ORAL REHABILITATION, 2006, 33 (04) : 313 - 315
  • [26] The evaluation of selected attachment systems for implant-retained overdenture based on retention characteristics analysis
    Chladek, Grzegorz
    Wrzus-Wielinski, Marcin
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2010, 12 (03) : 75 - 83
  • [27] Prosthetic complications in an implant-retained mandibular overdenture population: Initial analysis of a prospective study
    Chaffee, NR
    Felton, DA
    Cooper, LF
    Palmqvist, U
    Smith, R
    JOURNAL OF PROSTHETIC DENTISTRY, 2002, 87 (01): : 40 - 44
  • [28] Immediate Loading of Two Implants with a Mandibular Implant-Retained Overdenture: A New Treatment Protocol
    Stoker, Geert T.
    Wismeijer, Daniel
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2011, 13 (04) : 255 - 261
  • [29] Bar fracture of implant-retained overdenture: Protocol of a systematic review and meta-analysis
    Stanek, J.
    Riad, A.
    Slezakova, S.
    Azar, B.
    Klugarova, J.
    Pokorna, A.
    Klugar, M.
    JOURNAL OF OSSEOINTEGRATION, 2021, 13 (02) : 89 - 94
  • [30] The effect of attachment type and implant number on satisfaction and quality of life of mandibular implant-retained overdenture wearers
    Mumcu, Emre
    Bilhan, Hakan
    Geckili, Onur
    GERODONTOLOGY, 2012, 29 (02) : E618 - E623