Implant-retained overdenture delivery in 2 visits with a digital workflow

被引:1
|
作者
Jeong, Seung-Hoe [1 ]
Kim, Sunjai [1 ]
Seong, You Won [2 ]
Chang, Jae-Seung [1 ]
机构
[1] Yonsei Univ, Gangnam Severance Dent Hosp, Coll Dent, Dept Prosthodont, 211 Eonju Ro, Seoul 06273, South Korea
[2] Univ Tokyo, Grad Sch Publ Policy, Tokyo, Japan
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2023年 / 130卷 / 05期
基金
新加坡国家研究基金会;
关键词
DENTURES;
D O I
10.1016/j.prosdent.2021.12.023
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The conventional method of fabricating implant-retained overdentures involves multiple steps and patient visits. However, the duplication of existing complete dentures could decrease the number of visits and increase patient satisfaction. An existing maxillary implant-retained overdenture was replaced for a 78-year-old man; the existing implant-retained overdenture and his face were scanned at the first visit. The scanned intaglio image was inverted to obtain a virtual maxillary cast and used to fabricate the metal framework of the replacement implant-retained overdenture. Prefabricated artificial teeth were arranged on a 3-dimensional trial denture created from the scan data of the existing implant-retained overdenture. The replacement implantretained overdenture was fabricated on the metal framework by using the injection molding technique. By using these digital techniques, a stable and esthetic implant-retained overdenture was delivered in 2 visits. (J Prosthet Dent 2023;130:663-7)
引用
收藏
页码:663 / 667
页数:5
相关论文
共 50 条
  • [1] THE SERVICE LIFE OF IMPLANT-RETAINED OVERDENTURE ATTACHMENT SYSTEMS
    Pigozzo, Monica Nogueira
    Mesquita, Marcelo Ferraz
    Pessanha Henriques, Guilherme Elias
    Vaz, Luis Geraldo
    JOURNAL OF PROSTHETIC DENTISTRY, 2009, 102 (02): : 74 - 80
  • [2] In vitro assessment of polyetheretherketone for an attachment component for an implant-retained overdenture
    da Silva, Geyson Galo
    Wada Shimano, Marcos Vinicius
    Macedo, Ana Paula
    da Costa Valente, Mariana Lima
    dos Reis, Andrea Candido
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (02): : 319.e1 - 319.e8
  • [3] Oral Rehabilitation with Implant-Retained Overdenture in a Patient with Down Syndrome
    Altintas, Nuray Yilmaz
    Kilic, Serdar
    Altintas, Subutay Han
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (02): : E617 - E621
  • [4] Is the implant-retained overdenture a solution to improve the patient quality of life?
    Mourao, Carlos Fernando
    Han, Thomas J.
    EVIDENCE-BASED DENTISTRY, 2022, 23 (03) : 122 - 123
  • [5] RADIOGRAPHIC AND SURGICAL GUIDE FABRICATION FOR IMPLANT-RETAINED MANDIBULAR OVERDENTURE
    Wulfman, Claudine
    Hadida, Alain
    Rignon-Bret, Christophe
    JOURNAL OF PROSTHETIC DENTISTRY, 2010, 103 (01): : 53 - 57
  • [6] Implant Body Fracture Due to Fatigue in a Maxillary Implant-Retained Overdenture Treatment
    Terzioglu, Hakan
    Sarikaya, Can Hakan
    Gurbuz, Riza
    Karaagaclioglu, Lale
    CASE REPORTS IN DENTISTRY, 2025, 2025 (01)
  • [7] A Full Digital Workflow for the Duplication of an Existing Implant Retained Overdenture Prosthesis: A Novel Approach
    Tasopoulos, Theodoros
    Kouveliotis, George
    Karoussis, Ioannis
    Rfa Silva, Nelson
    Zoidis, Panagiotis
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 (07): : 555 - 560
  • [8] Mandibular implant-retained overdenture: A clinical trial of two anchorage systems
    Menicucci, G
    Lorenzetti, M
    Pera, P
    Preti, G
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 1998, 13 (06) : 851 - 856
  • [9] The 2-Visit CAD-CAM Implant-Retained Overdenture: A Clinical Report
    Bidra, Avinash S.
    JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 (06) : 722 - 728
  • [10] Fabrication of a mandibular implant-retained overdenture using an existing subperiosteal implant: A clinical report
    Arshad, Mahnaz
    Khoramshahi, Nourin
    Shirani, Gholamreza
    CLINICAL CASE REPORTS, 2024, 12 (04):