A rapid and convenient sample preparation method for the analysis of cannabinoids in oral fluid samples

被引:2
|
作者
Reinstadler, Vera [1 ]
Huber, Susanne [1 ]
Lierheimer, Stefan [2 ]
Boettcher, Michael [2 ]
Ruescher, Peter [3 ]
Tanzer, Martin [3 ]
Jenny, Kurt [3 ]
Zoll, Adolf [3 ]
Gruber, Wilhelm [3 ]
Oberacher, Herbert [1 ,4 ]
机构
[1] Med Univ Innsbruck, Inst Legal Med & Core Facil Metabol, Innsbruck, Austria
[2] MVZ Med Labore Dessau Kassel GmbH, Dessau Rosslau, Germany
[3] Landespolizeidirekt Vorarlberg, Bregenz, Austria
[4] Med Univ Innsbruck, Inst Legal Med & Core Facil Metabol, Muellerstr 44, A-6020 Innsbruck, Austria
关键词
cannabis; forensic toxicology; liquid chromatography-tandem mass spectrometry; oral fluid; saliva;
D O I
10.1002/bmc.5651
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cannabis is the world's most used illegal drug. The main psychoactive component of cannabis is Delta 9-tetrahydrocannabinol (THC). To aid the identification of cannabis-impaired individuals, a simple but effective workflow for reliable quantification of THC and its metabolites in oral fluid samples collected with the Greiner Bio-One Saliva Collection System is presented. Sampling involves rinsing the oral cavity with an extraction solution containing a citrate buffer stimulating salivary flow. Sample processing targeted the cannabinoid fraction interacting with proteins and other insoluble constituents that can be separated by centrifugation. Approximately 50% of the total amount of cannabinoids included in the oral fluid was recovered from the obtained pellet by extraction with acetonitrile. Liquid chromatography-tandem mass spectrometry was used for cannabinoid quantification. Fitness of the developed workflow for application in forensic and clinical cannabis testing was demonstrated by evaluating multiple performance parameters, including selectivity, linearity, limits of quantification (LOQs), accuracy, precision, matrix effects, extraction recoveries, process efficiencies and stability. Furthermore, sensitivity and specificity of the developed oral fluid-based cannabis test was demonstrated by analysing 195 samples collected either from opioid addicts or persons suspected of driving under the influence of drugs. The accuracy of identifying a person with the presence of THC in blood was found to be 97.9%.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Validation of microplastic sample preparation method for freshwater samples
    Mari, Aron
    Bordos, Gabor
    Gergely, Szilveszter
    Buki, Monika
    Hahn, Judit
    Palotai, Zoltan
    Besenyo, Gabriella
    Szabo, Eva
    Salgo, Andras
    Kriszt, Balazs
    Szoboszlay, Sandor
    WATER RESEARCH, 2021, 202
  • [22] SIMS Analysis of Hydrous Samples Using the Easy Introduction Method of Rapid Frozen Sample
    Ohishi, Kenji
    Kawakami, Isamu
    Okumura, Takao
    Sakamoto, Tetsuo
    BUNSEKI KAGAKU, 2014, 63 (05) : 391 - 397
  • [23] A rapid method for preparation of the cerebrospinal fluid proteome
    Larssen, Eivind
    Brede, Cato
    Hjelle, Anne Bjornstad
    Oysaed, Kjell Birger
    Tjensvoll, Anne Bolette
    Omdal, Roald
    Ruoff, Peter
    PROTEOMICS, 2015, 15 (01) : 10 - 15
  • [24] Analysis of cannabinoids in oral fluid by liquid chromatography–tandem mass spectrometry
    Marie Fabritius
    Christian Staub
    Patrice Mangin
    Christian Giroud
    Forensic Toxicology, 2013, 31 : 151 - 163
  • [25] Method to improve schemes of sample preparation and atomic-absorption analysis of geochemical samples
    Proidakova, O. A.
    Vasil'eva, I. E.
    INORGANIC MATERIALS, 2010, 46 (14) : 1503 - 1512
  • [26] Method to improve schemes of sample preparation and atomic-absorption analysis of geochemical samples
    O. A. Proidakova
    I. E. Vasil’eva
    Inorganic Materials, 2010, 46 : 1503 - 1512
  • [27] Sample preparation method for analysis of swipe samples by inductively coupled plasma mass spectrometry
    Szeles, Eva
    Varga, Zsolt
    Stefanka, Zsolt
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (07) : 1014 - 1018
  • [28] RAPID SAMPLE PREPARATION METHOD FOR POWDER DIFFRACTION CAMERAS
    OWEN, LB
    AMERICAN MINERALOGIST, 1971, 56 (9-10) : 1835 - &
  • [29] SIMPLE AND RAPID PREPARATION METHOD OF STANDARD SAMPLES OF PHEOPHYTINS
    HORI, H
    ISHITANI, O
    IBUSUKI, T
    INOUE, H
    BUNSEKI KAGAKU, 1994, 43 (11) : 939 - 945
  • [30] A RAPID METHOD FOR THE PREPARATION OF MULTIPLE SAMPLES OF EUKARYOTIC DNA
    REYMOND, CD
    NUCLEIC ACIDS RESEARCH, 1987, 15 (19) : 8118 - 8118