A rapid and convenient sample preparation method for the analysis of cannabinoids in oral fluid samples

被引:2
|
作者
Reinstadler, Vera [1 ]
Huber, Susanne [1 ]
Lierheimer, Stefan [2 ]
Boettcher, Michael [2 ]
Ruescher, Peter [3 ]
Tanzer, Martin [3 ]
Jenny, Kurt [3 ]
Zoll, Adolf [3 ]
Gruber, Wilhelm [3 ]
Oberacher, Herbert [1 ,4 ]
机构
[1] Med Univ Innsbruck, Inst Legal Med & Core Facil Metabol, Innsbruck, Austria
[2] MVZ Med Labore Dessau Kassel GmbH, Dessau Rosslau, Germany
[3] Landespolizeidirekt Vorarlberg, Bregenz, Austria
[4] Med Univ Innsbruck, Inst Legal Med & Core Facil Metabol, Muellerstr 44, A-6020 Innsbruck, Austria
关键词
cannabis; forensic toxicology; liquid chromatography-tandem mass spectrometry; oral fluid; saliva;
D O I
10.1002/bmc.5651
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cannabis is the world's most used illegal drug. The main psychoactive component of cannabis is Delta 9-tetrahydrocannabinol (THC). To aid the identification of cannabis-impaired individuals, a simple but effective workflow for reliable quantification of THC and its metabolites in oral fluid samples collected with the Greiner Bio-One Saliva Collection System is presented. Sampling involves rinsing the oral cavity with an extraction solution containing a citrate buffer stimulating salivary flow. Sample processing targeted the cannabinoid fraction interacting with proteins and other insoluble constituents that can be separated by centrifugation. Approximately 50% of the total amount of cannabinoids included in the oral fluid was recovered from the obtained pellet by extraction with acetonitrile. Liquid chromatography-tandem mass spectrometry was used for cannabinoid quantification. Fitness of the developed workflow for application in forensic and clinical cannabis testing was demonstrated by evaluating multiple performance parameters, including selectivity, linearity, limits of quantification (LOQs), accuracy, precision, matrix effects, extraction recoveries, process efficiencies and stability. Furthermore, sensitivity and specificity of the developed oral fluid-based cannabis test was demonstrated by analysing 195 samples collected either from opioid addicts or persons suspected of driving under the influence of drugs. The accuracy of identifying a person with the presence of THC in blood was found to be 97.9%.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Immunochromatography screening devices for cannabinoids in oral fluid sample
    Duarte, Jonathaline Apollo
    Gorziza, Roberta Petry
    Gonzalez, Marina
    Astolfi Picanco, Joao Marcelo
    Limberger, Renata Pereira
    BRAZILIAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2023, 59
  • [2] Supercritical fluid chromatographic method for the analysis of cannabinoids in extracts of cannabis samples
    Wang, M.
    Wang, Y. H.
    Avula, B.
    van Antwerp, J.
    Parcher, J. F.
    ElSohly, M. A.
    Khan, I. A.
    PLANTA MEDICA, 2015, 81 (11) : 878 - 878
  • [3] A proposed method of sample preparation and homogenization of hemp for the molecular analysis of cannabinoids
    Zachary P. Morehouse
    Gabriella L. Ryan
    Caleb M. Proctor
    Akelachi Okparanta
    Will Todd
    Derrick Bunting
    Taylor White
    Steven Parez
    Blessida Miller
    Veronica Colon
    Brandon Easparro
    James Atwood
    YoungChul Park
    Rodney J. Nash
    SN Applied Sciences, 2021, 3
  • [4] A proposed method of sample preparation and homogenization of hemp for the molecular analysis of cannabinoids
    Morehouse, Zachary P.
    Ryan, Gabriella L.
    Proctor, Caleb M.
    Okparanta, Akelachi
    Todd, Will
    Bunting, Derrick
    White, Taylor
    Parez, Steven
    Miller, Blessida
    Colon, Veronica
    Easparro, Brandon
    Atwood, James
    Park, YoungChul
    Nash, Rodney J.
    SN APPLIED SCIENCES, 2021, 3 (08):
  • [5] A rapid capillary electrophoresis method with LED-induced native fluorescence detection for the analysis of cannabinoids in oral fluid
    Mazina, Jekaterina
    Spiljova, Anastassija
    Vaher, Merike
    Kaljurand, Mihkel
    Kulp, Maria
    ANALYTICAL METHODS, 2015, 7 (18) : 7741 - 7747
  • [6] A rapid sample preparation method for the analysis of stable isotope ratios of beef samples from different countries
    Zhao, Shanshan
    Zhang, Hongbo
    Zhang, Bin
    Xu, Zhenzhen
    Chen, Ailiang
    Zhao, Yan
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2020, 34 (13)
  • [7] A Validated Method for the Detection of Synthetic Cannabinoids in Oral Fluid
    Williams, Michelle
    Martin, Jennifer
    Galettis, Peter
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2019, 43 (01) : 10 - 17
  • [8] Rapid and convenient method for the preparation of conductivity water
    Clevenger, CB
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY-US, 1919, 11 (05): : 964 - 966
  • [9] Development and validation of a method for analysis of 25 cannabinoids in oral fluid and exhaled breath condensate
    Swaminathan, Meena
    Tarifa, Anamary
    Decaprio, Anthony P.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (19) : 4325 - 4340
  • [10] A systematic review of quantitative analysis of cannabinoids in oral fluid
    Gorziza, Roberta Petry
    Duarte, Jonathaline Apollo
    Gonzalez, Marina
    Arroyo-Mora, Luis E.
    Limberger, Renata Pereira
    JOURNAL OF FORENSIC SCIENCES, 2021, 66 (06) : 2104 - 2112