Performance Study of Booster-Driven Hybrid Cooling Units for Free Cooling in Data Centers

被引:2
|
作者
Zhuang, Rong [1 ,2 ]
Zhou, Feng [3 ]
Tian, Xuwen [3 ]
Xu, Buqing [3 ]
Li, Shaocong [3 ]
Ma, Guoyuan [3 ]
机构
[1] State Key Lab Air Conditioning Equipment & Syst En, Zhuhai 519070, Peoples R China
[2] Gree Elect Appliances Inc Zhuhai, Zhuhai 519000, Peoples R China
[3] Beijing Univ Technol, Dept Refrigerat & Cryogen Engn, Beijing 100124, Peoples R China
关键词
data center; booster; free cooling; thermal performance; LOOP;
D O I
10.3390/su151914558
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In the data center, using ambient energy cooling technology can effectively reduce the average power use efficiency, and the heat pipe as an effective use of ambient energy device has attracted much attention. For the dynamic heat pipe, reducing the power consumption of the pump effectively is the key to improving the efficiency. In this paper, the rotary booster is selected as the gas phase booster device of the heat pipe unit, the standard unit of the rotary booster is improved, and three types of boosters are obtained, including two improved boosters and one standard unit. Comparative test studies are conducted on three different types of boosters, and the power of the booster shows a downward trend with the increase in indoor and outdoor temperature differences (outdoor temperature decreases). With the increase in indoor and outdoor temperature differences, the cooling capacity increases first and then decreases. When the indoor and outdoor temperature difference is greater than 20 degrees C, the suction pressure of the booster is greater than the saturated condensing pressure force under outdoor ambient temperature, and the work of the booster decreases. Among the three types of boosters, the medium pressure ratio booster energy efficiency ratio (EER) is the largest. After throttling the standard unit, results show that its cooling capacity unit increases, but the booster power also increases, and the EER is still smaller than that of the improved unit.
引用
收藏
页数:19
相关论文
共 50 条
  • [41] REAR DOOR HEAT EXCHANGER COOLING PERFORMANCE IN TELECOMMUNICATION DATA CENTERS
    Mynampati, Venkata Naga Poornima
    Karajgikar, Saket
    Sheerah, Ibraheem
    Agonafer, Dereje
    Novotny, Shlomo
    Schmidt, Roger
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION 2010, VOL 4, 2012, : 417 - +
  • [42] ASSESSMENT OF THE ENERGY PERFORMANCE OF COGENERATION SYSTEMS FOR POWERING AND COOLING DATA CENTERS
    Ringham, Dale C.
    Rice, Dan J.
    Granetz, Brian S.
    Erden, Hamza Salih
    Khalifa, H. Ezzat
    Schmidt, Roger R.
    PROCEEDINGS OF THE ASME INTERNATIONAL TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC MICROSYSTEMS, 2013, VOL 2, 2014,
  • [43] Experimental study on the performance of a novel hybrid indirect evaporative cooling/thermoelectric cooling system
    Zhou Y.
    Yan Z.
    Dai Q.
    Yu Y.
    Building and Environment, 2022, 207
  • [44] A numerical study of the effect of a hybrid cooling system on the cooling performance of a large power transformer
    Kim, Young Joo
    Jeong, Myunggeun
    Park, Yong Gap
    Ha, Man Yeong
    APPLIED THERMAL ENGINEERING, 2018, 136 : 275 - 286
  • [45] Power usage effectiveness analysis of a liquid-pump-driven hybrid cooling system for data centers in subclimate zones
    Zhou, Feng
    Shen, Chaoya
    Ma, Guoyuan
    Yan, Xianghui
    SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2022, 52
  • [46] The Analysis of Modifications in Cooling Systems for High-Performance Data Centers. A Case Study
    Rusowicz, Artur
    Rucinski, Adam
    Laskowski, Rafal
    10TH INTERNATIONAL CONFERENCE ENVIRONMENTAL ENGINEERING (10TH ICEE), 2017,
  • [47] Study on the Performance of a Newly Designed Cooling System Utilizing Dam Water for Internet Data Centers
    Anka, Selorm Kwaku
    Boafo, Nicholas Lamptey
    Mensah, Kwesi
    Boahen, Samuel
    Lee, Kwang Ho
    Choi, Jong Min
    ENERGIES, 2022, 15 (24)
  • [48] Energy and economic assessment of major free cooling retrofits for data centers in Turkey
    Gozcu, Ozan
    Erden, Hamza Salih
    TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2019, 27 (03) : 2197 - 2212
  • [49] Experimental investigation on a loop thermosyphon with evaporative condenser for free cooling of data centers
    Shao, Shuangquan
    Liu, Haichao
    Zhang, Hainan
    Tian, Changqing
    ENERGY, 2019, 185 : 829 - 836
  • [50] Prognostics-based Health Management for Free Air Cooling of Data Centers
    Dai, Jun
    Das, Diganta
    Pecht, Michael
    2010 PROGNOSTICS AND SYSTEM HEALTH MANAGEMENT CONFERENCE, 2010, : 527 - 532