3-Dimensional Sonic Phase-invariant Echo Localization

被引:2
|
作者
Hahne, Christopher [1 ]
机构
[1] Univ Bern, ARTORG Ctr, Artificial Intelligence Med Imaging Grp, CH-3008 Bern, Switzerland
关键词
D O I
10.1109/ICRA48891.2023.10161199
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Parallax and Time-of-Flight (ToF) are often regarded as complementary in robotic vision where various light and weather conditions remain challenges for advanced camera-based 3-Dimensional (3-D) reconstruction. To this end, this paper establishes Parallax among Corresponding Echoes (PaCE) to triangulate acoustic ToF pulses from arbitrary sensor positions in 3-D space for the first time. This is achieved through a novel round-trip reflection model that pinpoints targets at the intersection of ellipsoids, which are spanned by sensor locations and detected arrival times. Inter-channel echo association becomes a crucial prerequisite for target detection and is learned from feature similarity obtained by a stack of Siamese Multi-Layer Perceptrons (MLPs). The PaCE algorithm enables phase-invariant 3-D object localization from only 1 isotropic emitter and at least 3 ToF receivers with relaxed sensor position constraints. Experiments are conducted with airborne ultrasound sensor hardware and back this hypothesis with quantitative results.
引用
收藏
页码:4121 / 4127
页数:7
相关论文
共 50 条
  • [41] PHASE-INVARIANT SOLUTIONS OF NONLINEAR WAVE-WAVE INTERACTING SYSTEMS
    WANG, PKC
    PHYSICA A, 1975, 81 (03): : 441 - 453
  • [42] LOCALIZATION IN DISORDERED TWO-DIMENSIONAL AND 3-DIMENSIONAL SYSTEMS
    SOUKOULIS, CM
    ECONOMOU, EN
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1981, 26 (03): : 217 - 217
  • [43] REPRODUCIBLE MEASUREMENT OF VENTRICULAR VOLUME BY 3-DIMENSIONAL ECHO RECONSTRUCTION
    PEARLMAN, AS
    MORITZ, WE
    MEDEMA, D
    MCCABE, D
    AMERICAN JOURNAL OF CARDIOLOGY, 1982, 49 (04): : 896 - 896
  • [44] 3-DIMENSIONAL TRANSESOPHAGEAL ECHO IMAGING OF THE DESCENDING THORACIC AORTA
    ROSS, JJ
    DADAMO, AJ
    KARALIS, DG
    CHANDRASEKARAN, K
    AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (11): : 1000 - 1002
  • [45] SELECTIVE CHEMICAL IMAGING WITH A 3-DIMENSIONAL GRADIENT ECHO SEQUENCE
    KLOSE, U
    GRODD, W
    KOLBEL, G
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1989, 13 (04) : 724 - 729
  • [46] 3-DIMENSIONAL ECHO VS 2-DIMENSIONAL ECHO FOR LV VOLUME DETERMINATION IN PATIENTS WITH ABNORMAL VENTRICLES
    SAPIN, PM
    SCHROEDER, KM
    GOPAL, AA
    KELLER, AM
    SHEN, ZQ
    SMITH, MD
    KING, DL
    CIRCULATION, 1993, 88 (04) : 162 - 162
  • [47] A 3-DIMENSIONAL MODEL FOR THE OCTAGONAL PHASE
    TORRES, M
    PASTOR, G
    JIMENEZ, I
    PHILOSOPHICAL MAGAZINE LETTERS, 1990, 61 (05) : 305 - 310
  • [48] 3-DIMENSIONAL IMAGING OF PHASE STEPS
    SHEPPARD, CJR
    CARLINI, AR
    MATTHEWS, HJ
    OPTIK, 1988, 80 (03): : 91 - 94
  • [49] THE JONES-WITTEN INVARIANT FOR FLOWS ON A 3-DIMENSIONAL MANIFOLD
    VERJOVSKY, A
    FREYER, RFV
    COMMUNICATIONS IN MATHEMATICAL PHYSICS, 1994, 163 (01) : 73 - 88
  • [50] Left invariant Randers metrics on the 3-dimensional Heisenberg group
    Toth, A. Lengyelne
    Kovacs, Zoltan
    PUBLICATIONES MATHEMATICAE-DEBRECEN, 2014, 85 (1-2): : 161 - 179