摘要
Previously, activated carbon was used as adsorbent for the removal of heavy metals at batch scale and the reported removal efficiency was up to 25 % (while in our technique the efficiency is up to 75%). The large industries operate with continuous processes and discharge large amount of wastewater containing heavy metals. No research was published for continuous operation using fluidized bed adsorption column till now. The novelty of this study is on the mode of operation (continuous operation at large scale under fixed and fluidized bed conditions), Biosorbent activated carbon (AC), and maximum efficiency of arsenic removal (i.e. 75 %). The Biosorbent activated carbon prepared from waste agriculture material. Industrial wastewater consists of many inorganic and organic pollutants which are discharged into water bodies resulting the serious health problems. Now a days, concentration of arsenic has much increased as compared to the permissive concentration level (25mg/L). Therefore, there is need to reduce this concentration up to threshold value (10 mu g/L). The use of biosorbents for arsenic removal from wastewater has global significance due to its widespread availability and low cost. Biosorption of Arsenic strongly depends on the initial metal concentration, contact time, speed of stirring, pH and temperature. The maximum arsenic as (III) removed at pH-7.5 is 70%, it was improved to 83% by agitation in batch experiments. While in continuous mode experiments (Fixed bed) the bed height and flow rates were varied. At the Fluidized bed experiments, the maximum As (III) removed was 75%. The effects of several factors such as pH, initial solute concentration, biosorbents dose, has been revaluated in this paper. The low cost, easily available biosorbent AC is recommended for removal of arsenic from contaminated wastewaters to bring them in compliance.
引用
收藏
页码:154 / 164
页数:11
相关论文
共 50 条
  • [41] Treatment of toxic industrial wastewater in fluidized and fixed-bed batch reactors with Trametes versicolor:: Influence of immobilisation
    Font, X.
    Caminal, G.
    Gabarrell, X.
    Vicent, T.
    ENVIRONMENTAL TECHNOLOGY, 2006, 27 (08) : 845 - 854
  • [42] Removal of lead, cadmium, copper, and arsenic ions using biosorption: equilibrium and kinetic studies
    Sulaymon, Abbas H.
    Mohammed, Ahmed A.
    Al-Musawi, Tariq J.
    DESALINATION AND WATER TREATMENT, 2013, 51 (22-24) : 4424 - 4434
  • [43] Simultaneous removal of selenite and heavy metals from wastewater and their recovery as nanoparticles using an inverse fluidized bed bioreactor
    Sinharoy, Arindam
    Kumar, Manoj
    Chaudhuri, Rayanee
    Saikia, Sudeshna
    Pakshirajan, Kannan
    JOURNAL OF CLEANER PRODUCTION, 2022, 376
  • [44] Removal of metronidazole from wastewater by Fe/charcoal micro electrolysis fluidized bed reactor
    Malakootian, Mohammad
    Kannan, Karthik
    Gharaghani, Majid Amiri
    Dehdarirad, Abbas
    Nasiri, Alireza
    Shahamat, Yousef Dadban
    Mahdizadeh, Hakimeh
    JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2019, 7 (06):
  • [45] Effective Phosphate Removal from Synthesized Wastewater Using Copper-Chitosan Bead: Batch and Fixed-Bed Column Studies
    An, Byungryul
    Jung, Ka-Young
    Lee, Sang-Hyup
    Lee, Seunghak
    Choi, Jae-Woo
    WATER AIR AND SOIL POLLUTION, 2014, 225 (08):
  • [46] Fixed bed column study for Cd(II) removal from wastewater using treated rice husk
    Kumar, U
    Bandyopadhyay, M
    JOURNAL OF HAZARDOUS MATERIALS, 2006, 129 (1-3) : 253 - 259
  • [47] Cd removal from wastewater by sulfate reducing bacteria with an anaerobic fluidized bed reactor
    Ma Xiaohang
    Hua Yaoxi
    Jiang Feng Institute of Microbiology of Zhejiang Province
    Hangzhou 310012
    China Liu Jian Environmental Protection Institute of Zhejiang Province
    Hangzhou 310007
    China Ye Xieming Metallurgical Institute of Zheji
    Journal of Environmental Sciences , 1997, (03)
  • [48] Application of an agro-industrial waste for the removal of As (III) in a counter-current multiphase fluidized bed
    De, D.
    Aniya, V.
    Satyavathi, B.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2019, 16 (01) : 279 - 294
  • [49] Application of an agro-industrial waste for the removal of As (III) in a counter-current multiphase fluidized bed
    D. De
    V. Aniya
    B. Satyavathi
    International Journal of Environmental Science and Technology, 2019, 16 : 279 - 294
  • [50] Lead removal from wastewater by cementation utilising a fixed bed of iron spheres
    Agelidis, T.
    Fytianos, K.
    Vasilikiotis, G.
    1600, (50):