Full-scale validation of optimal axial induction control of a row of turbines at Lillgrund wind farm

被引:2
|
作者
Bossanyi, Ervin [1 ]
Larsen, Gunner C. [2 ]
Pedersen, Mads M. [2 ]
机构
[1] DNV, One Linear Pk,Avon St, Bristol BS2 0PS, Avon, England
[2] DTU Wind & Energy Syst, Response Aeroelast Control & Hydrodynam Sect, DK-4000 Roskilde, Denmark
来源
WAKE CONFERENCE 2023 | 2023年 / 2505卷
关键词
TOPFARM;
D O I
10.1088/1742-6596/2505/1/012042
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
We present a full-scale validation study of an optimal power open-loop wind farm control schedule ( WFCS) using a full row of turbines (Row-A) at the Lillgrund offshore wind farm as the demonstration case. The derived WFCS is conditioned on the ambient wind speed and wind direction. The WFCS's are developed using the DNV and DTU numerical models LongSim and Fuga. Prior to implementation, the developed optimal controllers are tested by comparing LongSim results, based on Fuga optimized input, with Fuga optimized results and vice versa. These models are very different in their nature. Fuga being a linearized RANS CFD solver, and LongSim being based on a range of engineering wake models and allowing for unsteady wind farm flow modelling. but nevertheless the overall computed Row-A power gains are reasonably similar. This gives confidence to the developed WFCS's, even though the two models predict significantly different distributions of the power gains over wind speeds and directions. Based on the numerical analysis, simplified WFCS's for implementation in the RowA turbines are developed and tested against the more detailed optimized controller. The test predicts only a small reduction of performance enhancement of the simplified controller compared to the detailed controller, and on this basis it is decided to use the simplified controller for the full-scale turbine implementation. The test, toggling between base control and optimal control in 50-minute successive time slots, has been running since 09-05-2022 and is still ongoing. A huge amount of data is needed to obtain robust statistics for the comparison of measured and numerical data.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Mechanism of frequency instability of full-scale wind turbines caused by grid short circuit fault and its control method
    Han G.
    Zhang C.
    Cai X.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2018, 33 (10): : 2167 - 2175
  • [22] SIMULATION OF WAVE IMPACTS AT BELWIND OFFSHORE WIND FARM AND COMPARISON WITH FULL-SCALE MEASUREMENTS
    Bunnik, Tim
    Weijtjens, Wout
    Devriendt, Christof
    PROCEEDINGS OF THE ASME 36TH INTERNATIONAL CONFERENCE ON OCEAN, OFFSHORE AND ARCTIC ENGINEERING, 2017, VOL 10, 2017,
  • [23] Analytical downburst wind load calculation methods: Review and full-scale validation
    Mengistu, Mekdes T.
    Repetto, Maria Pia
    ENGINEERING STRUCTURES, 2024, 321
  • [24] Measurements of tower deflections on full-scale wind turbines using an opto-mechanical platform
    Zendehbad, M.
    Chokani, N.
    Abhari, R. S.
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2017, 168 : 72 - 80
  • [25] A digital twin solution for floating offshore wind turbines validated using a full-scale prototype
    Branlard, Emmanuel
    Jonkman, Jason
    Brown, Cameron
    Zhang, Jiatian
    WIND ENERGY SCIENCE, 2024, 9 (01) : 1 - 24
  • [26] On the Architecture of Wind Turbine Control Required for Induction-based Optimal Wind Farm Control
    Kazda, J.
    Mirzaei, M.
    Cutululis, N. A.
    2018 ANNUAL AMERICAN CONTROL CONFERENCE (ACC), 2018, : 3074 - 3079
  • [27] Effects of axial induction control on wind farm energy production - A field test
    van der Hoek, Daan
    Kanev, Stoyan
    Allin, Julian
    Bieniek, David
    Mittelmeier, Niko
    RENEWABLE ENERGY, 2019, 140 : 994 - 1003
  • [28] Voltage Source Control of Wind Turbines With Full-scale Converters (Part I): Control Architecture and Stability Analysis Under Weak Grid Conditions
    Sang S.
    Zhang C.
    Cai X.
    Wang C.
    Yang Z.
    Ai S.
    Wang H.
    Rao F.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2021, 41 (16): : 5604 - 5615
  • [29] Full-Scale Validation of Dynamic Wind Load on a Super-Tall Building under Strong Wind
    Au, Siu-Kui
    To, Ping
    JOURNAL OF STRUCTURAL ENGINEERING, 2012, 138 (09) : 1161 - 1172
  • [30] Validation of Type 4 Wind Turbine Generic Simulation Model by Full-Scale Test
    Seman, S.
    Simolin, J.
    Matsinen, J-P
    Niiranen, J.
    9TH INTERNATIONAL WORKSHOP ON LARGE-SCALE INTEGRATION OF WIND POWER INTO POWER SYSTEMS AS WELL AS ON TRANSMISSION NETWORKS FOR OFFSHORE WIND POWER PLANTS, 2010, : 487 - 492