A modelling study on the frosting characteristics of a novel dual-fan outdoor coil in an Air Source Heat Pump unit

被引:6
|
作者
Bai, Xiaoxia [1 ]
Liu, Shengnan [1 ]
Deng, Shiming [2 ]
Zhang, Long [3 ]
Wei, Minchen [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Environm & Energy Engn, Hong Kong, Peoples R China
[2] Qatar Univ, Dept Mech & Ind Engn, POB 2713, Doha, Qatar
[3] Beijing Inst Technol, Sch Mech Engn, Dept Energy & Power Engn, Beijing, Peoples R China
关键词
Air source heat pump; Novel dual -fan outdoor coil; Dynamic mathematical model; Even frosting characteristics; Heating performances; PERFORMANCE; GROWTH; EXCHANGER; FLOW; FIN; TEMPERATURE; PREDICTION; DEFROST;
D O I
10.1016/j.applthermaleng.2022.119933
中图分类号
O414.1 [热力学];
学科分类号
摘要
Uneven frosting along the airflow direction in a traditional outdoor coil in air source heat pumps (ASHPs) was inevitable due to a fixed one-way outdoor airflow direction, causing a rapid deterioration in heating performances of ASHPs. To alleviate this uneven frosting phenomenon, a novel dual-fan outdoor coil where air flow direction can be alternately reversed was proposed in a previous experimental study. To more effectively and comprehensively study the operating characteristics of ASHPs having the dual-fan outdoor coil at different fan operating modes, with different configurations and under different operating ambient conditions, a dynamic mathematical model for the experimental ASHP having the dual-fan outdoor coil was developed and experimentally validated. Then a follow-up modelling study for different operating modes of the two fans, fin pitches and operating ambient conditions was carried out using the validated model. The modelling results demonstrated that by optimizing fan operating mode, the difference in frost thickness between the windward and leeward sides of the dual-fan outdoor coil can be reduced by up to 77.3 %, the averaged output heating capacity and COP improved by up to 11.1 % and 12.7 %, respectively, and the number of switching operation of the two fans decreased by 55.6 %. Besides, the recommendations for using the dual-fan outdoor coil at different operating modes of the two fans, different fin pitches and operating ambient conditions were also made. The model can be used as a useful tool in helping achieve higher operating efficiency for ASHPs having the novel dual-fan outdoor coil.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Experimental study of solution defrosting characteristics of air source heat pump
    Jiang, Ping
    Zhang, Yu
    Fan, Hongxiu
    Jin, Qi
    Yu, Yanshun
    APPLIED THERMAL ENGINEERING, 2024, 236
  • [42] A modeling study on developing the condensing-frosting performance maps for a variable speed air source heat pump
    Liu, Shengnan
    Bai, Xiaoxia
    Deng, Shiming
    Zhang, Long
    Wei, Minchen
    JOURNAL OF BUILDING ENGINEERING, 2022, 58
  • [43] Performance of an air-source heat pump with multi-circuit outdoor coil for continuous heating during defrosting
    Tang, Lan
    Liu, Xi 'an
    He, Shiquan
    Li, Qingjian
    JOURNAL OF BUILDING ENGINEERING, 2024, 85
  • [44] Energy transfer procession in an air source heat pump unit during defrosting with melted frost locally drainage in its multi-circuit outdoor coil
    Song, Mengjie
    Dang Chaobin
    Ning, Mao
    Deng Shiming
    ENERGY AND BUILDINGS, 2018, 164 : 109 - 120
  • [45] Experimental Study on a Novel Defrost Cycle for Air Source Heat Pump
    Fu Wencheng
    Gun Xianmin
    Tao Xiaocheng
    ACRA 2009: PROCEEDINGS OF THE 4TH ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, 2009, : 529 - 534
  • [46] EXPERIMENTAL STUDY ON A NOVEL DEFROST CYCLE FOR AIR SOURCE HEAT PUMP
    Guo, Xian-Min
    Wang, Ya-Jing
    Fu, Wen-Cheng
    Tao, Xiang-Cheng
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2010, 18 (01) : 77 - 84
  • [47] An experimental study on energy-storage based defrosting performance of an air source heat pump system with a micro-channel heat exchanger as outdoor coil
    Xu, Zhenjun
    Han, Lu
    APPLIED THERMAL ENGINEERING, 2024, 240
  • [48] Analysis of a HVAC zoning control system with an air-to-water heat pump and a ducted fan coil unit in residential buildings
    Hernandez, Francisco Fernandez
    Atienza-Marquez, Antonio
    Suarez, Jose Miguel Pena
    Cantalejo, Juan Antonio Bandera
    Muriano, Mari Carmen Gonzalez
    APPLIED THERMAL ENGINEERING, 2022, 215
  • [49] A novel coefficient of frosting suppression based on the real-time operating characteristics of air source heat pumps
    Lin, Yao
    Sun, Yuying
    Luo, Jianfei
    Wei, Wenzhe
    Wang, Wei
    Luo, Qing
    Liu, Shengnan
    Deng, Shiming
    ENERGY AND BUILDINGS, 2023, 284
  • [50] Heating performance characteristics of a dual source heat pump using air and waste heat in electric vehicles
    Ahn, Jae Hwan
    Kang, Hoon
    Lee, Ho Seong
    Jung, Hae Won
    Baek, Changhyun
    Kim, Yongchan
    APPLIED ENERGY, 2014, 119 : 1 - 9