Fire tests of steel-to-timber connections with high fire resistance

被引:1
|
作者
Dhima, Dhionis [1 ]
Audebert, Maxime [2 ]
Bouchair, Abdelhamid [3 ]
Pinoteau, Nicolas [1 ]
机构
[1] Ctr Sci & Tech Baiment, Dept Securite Struct & Feu, CSTB, Marne La Vallee, France
[2] Univ Lyon, Lab Tribol & Dynam Syst LTDS, Ecole Natl Ingenieur St Etienne, UMR 5513, 58 Rue Jean Parot, St Etienne 2, France
[3] Univ Clermont Auvergne, SIGMA Clermont, CNRS, Inst Pascal, Clermont Ferrand, France
关键词
THERMOMECHANICAL BEHAVIOR;
D O I
10.1002/fam.3083
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper presents the results of twenty-one fire tests on unprotected steel-to-timber connections with dowel-type fasteners and one or two slotted-in steel plates. The experimental results of this type of connections available in existing studies have been mostly limited to a fire resistance duration of 60 min. The tests performed in this study target a significant increase of fire resistance to reach 90 and 120 min. Two configurations of connections with one and two slotted-in steel plates, i.e., two or four shear planes, were tested. The temperatures were measured at different locations in the wood members and along the steel plates. Two load levels for fire tests were determined on the basis of tests performed at ambient temperature. The experimental results show that the specimens proposed for steel-to-timber connections with dowel-type fasteners are suitable for achieving fire resistance of 90 and 120 min.
引用
收藏
页码:120 / 138
页数:19
相关论文
共 50 条
  • [41] Fire Resistance of Steel Beam to Column End Plate Connections
    Petrina, Tudor
    WORLD MULTIDISCIPLINARY CIVIL ENGINEERING-ARCHITECTURE-URBAN PLANNING SYMPOSIUM 2016, WMCAUS 2016, 2016, 161 : 143 - 149
  • [42] STUDY OF THE FIRE PERFORMANCE OF HYBRID STEEL-TIMBER CONNECTIONS WITH FULL-SCALE TESTS AND FINITE ELEMENT MODELLING
    Akotuah, Aaron O.
    Ali, Sabah G.
    Erochko, Jeffrey
    Zhang, Xia
    Hadjisophocleous, George V.
    APPLICATIONS OF STRUCTURAL FIRE ENGINEERING, 2017,
  • [43] Investigating brittle failures in multiple-nail steel-to-timber connections
    Dupleix, A.
    Quenneville, P.
    AUSTRALIAN JOURNAL OF CIVIL ENGINEERING, 2012, 10 (02) : 129 - 142
  • [44] Fire Resistance of Unprotected Steel Beams - Comparison between Fire Tests and Calculation Models
    Lukomski, Marek
    Turkowski, Piotr
    Roszkowski, Pawel
    Papis, Bartlomiej
    MODERN BUILDING MATERIALS, STRUCTURES AND TECHNIQUES, 2017, 172 : 665 - 672
  • [45] Mechanical Behavior and Modeling of Dowelled Steel-to-Timber Moment-Resisting Connections
    Xu, Bo-Han
    Bouchair, Abdelhamid
    Racher, Patrick
    JOURNAL OF STRUCTURAL ENGINEERING, 2015, 141 (06)
  • [46] Experimental Assessment of the Fire Resistance Mechanisms of Timber-Steel Composites
    Le, Truong Di Ha
    Tsai, Meng-Ting
    MATERIALS, 2019, 12 (23)
  • [47] Analytical modelling of cold-formed steel-to-timber connections with inclined screws
    Vella, Nathan
    Gardner, Leroy
    Buhagiar, Spiridione
    ENGINEERING STRUCTURES, 2021, 249
  • [48] Experimental study on fire resistance of bolted steel-PSB-steel connections
    Cui Z.
    Hui B.
    Xu M.
    Chen Z.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2019, 40 (09): : 20 - 27
  • [49] Experimental analysis of cold-formed steel-to-timber connections with inclined screws
    Vella, Nathan
    Gardner, Leroy
    Buhagiar, Spiridione
    STRUCTURES, 2020, 24 : 890 - 904
  • [50] Fire resistance and burnout resistance of timber columns
    Gernay, Thomas
    FIRE SAFETY JOURNAL, 2021, 122