Three-dimensional-printed patient-specific guides for tibial deformity correction in small-breed dogs

被引:0
|
作者
Jeon, Ji-Won [1 ,2 ]
Kang, Kyu-Won [1 ,2 ]
Kim, Woo-Keyoung [1 ,2 ,3 ]
Jung, Changsu [4 ]
Kang, Byung-Jae [1 ,2 ,3 ]
机构
[1] Seoul Natl Univ, Coll Vet Med, Dept Vet Clin Sci, Seoul, South Korea
[2] Seoul Natl Univ, Res Inst Vet Sci, Seoul, South Korea
[3] Seoul Natl Univ, BK21 FOUR Future Vet Med Leading Educ & Res Ctr BK, Seoul, South Korea
[4] Ilsan Anim Med Ctr, Gyeonggi Do, South Korea
基金
新加坡国家研究基金会;
关键词
tibial deformity; corrective osteotomy; 3-D-printed guide; closing wedge osteotomy; small-breed dog; PLATEAU LEVELING OSTEOTOMY; CRUCIATE LIGAMENT DISEASE; MEDIAL PATELLAR LUXATION; CLOSING WEDGE OSTEOTOMY; SURGICAL-CORRECTION; ANTEBRACHIAL DEFORMITY; COMPUTED-TOMOGRAPHY; PREMATURE CLOSURE; DEFICIENT STIFLES; RADIAL TORSION;
D O I
10.2460/ajvr.23.06.0146
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
OBJECTIVE To describe the use of patient-specific 3-D-printed osteotomy, reduction, and compression guides for tibial closing wedge osteotomy in small-breed dogs.ANIMALS6 dogs with unilateral tibial deformities.METHODSSix small-breed dogs with 1 or a combination of tibial deformities, including excessive tibial plateau angle, valgus, and torsion, were scheduled to undergo tibial closing wedge osteotomy using patient-specific 3-D-printed oste- otomy, reduction, and compression guides. The location and orientation of the wedge osteotomy were determined based on CT data using computer-aided design software. After the tibial deformities were corrected, postoperative CT or radiographs were obtained to compare the achieved tibial limb angles with the planned angles. Clinical evalu-ation and radiographic follow-up were performed on all dogs.RESULTSGuides were successfully positioned at each specific location, and osteotomies were performed without radiation exposure or observer assistance in all dogs. Tibial deformities were corrected with angular errors of 1.8 +/- 1.4 degrees, 2.3 +/- 2.1 degrees, and 2.6 +/- 1.3 degrees in the sagittal, frontal, and transverse planes, respectively. Mild complications resolved within 1 month in 3 dogs, and revision surgery was not required. Five dogs improved to the normal gait (mean, 14.8 +/- 6.6 weeks), and 1 dog recovered a satisfactory gait 24 weeks after surgery. All limbs healed 14 +/- 4.7 weeks after surgery.CLINICAL RELEVANCEPatient-specific 3-D-printed osteotomy, reduction, and compression guides can provide effective assistance allow- ing accurate correction of tibial deformities. Their use yields good clinical outcomes in small-breed dogs.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] A three-dimensional printed patient-specific scaphoid replacement: a cadaveric study
    Honigmann, Philipp
    Schumacher, Ralf
    Marek, Romy
    Buttner, Franz
    Thieringer, Florian
    Haefeli, Mathias
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2018, 43 (04) : 407 - 412
  • [42] Students' Perception of Remote Extended Reality Simulation Systems Using Patient-specific Three-Dimensional-printed Models in Endodontic Education: A Pilot Study
    Alroomy, Riyadh
    Almimoni, Munirah
    Alotaibi, Abdulaaly
    Almutairi, Ahad
    Alyahya, Ebtesam
    Unozawa, Motoharu
    Kakumoto, Takahito
    Okazaki, Katsushi
    EUROPEAN ENDODONTIC JOURNAL, 2024, 9 (03): : 273 - 278
  • [43] Patient-Specific Three-Dimensional-Printed and Bolus Material-Based Localization Grids for Magnetic Resonance Imaging-Guided Interventional Procedures
    Chu, Vivien W. S.
    Wong, Wing Ki
    Lee, Louis
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2024, 18 (01):
  • [44] Three-dimensional-printed custom guides for bipolar coxofemoral osteochondral allograft in dogs (vol 16, e0244208, 2021)
    De Armond, Christina C.
    Kim, Stanley E.
    Lewis, Daniel D.
    Biedrzycki, Adam H.
    Banks, Scott A.
    Cook, James L.
    Keister, Justin D.
    PLOS ONE, 2021, 16 (11):
  • [45] Comparison of digitally assessed quality of posterior crown preparations performed with and without previous practice on patient-specific three-dimensional-printed teeth models
    Tricio, Jorge A.
    Braithwaite, Catalina
    Herrera, Constanza M.
    Vicuna, Daniela P.
    Cacciuttolo, Franco R.
    Jorquera, Gilbert A.
    Gutierrez, Mario F.
    Cordova, Christian G.
    Villalon, Pablo A.
    Moncada, Gustavo A.
    Casanova, Renzo A.
    Gonzalez, Maria I.
    Ilic, Macarena A.
    Orsini, Cesar A.
    JOURNAL OF DENTAL EDUCATION, 2024, 88 (09) : 1247 - 1256
  • [46] Efficacy of two reduction methods in conjunction with 3-D-printed patient-specific pin guides for aligning simulated comminuted tibial fractures in cadaveric dogs
    Johnson, Matthew D.
    Lewis, Daniel D.
    Sutton, William A.
    Scheuermann, Logan M.
    De Armond, Christina C.
    Kim, Stanley E.
    Biedrzycki, Adam H.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2022, 83 (09)
  • [47] Three cases of posttraumatic wrist problems solved with 3D-printed patient-specific guides
    Haandrikman, Susan
    Schroder, Femke F.
    de Graaff, Feike
    Heuvel, Judith Olde
    Vochteloo, Anne J. H.
    CASE REPORTS IN PLASTIC SURGERY AND HAND SURGERY, 2024, 11 (01):
  • [48] A 3-Dimensional Printed Patient-Specific Surgical Guide to Facilitate Transsphenoidal Hypophysectomy in Dogs
    Escauriaza, Leticia
    Fenn, Joe
    McCue, John
    Roper, Darren
    Vandenberghe, Helene
    Nye, George
    Oxley, Bill
    Granger, Nicolas
    FRONTIERS IN VETERINARY SCIENCE, 2022, 9
  • [49] A novel combination of computer-assisted reduction technique and three dimensional printed patient-specific external fixator for treatment of tibial fractures
    Feng Qiao
    Dichen Li
    Zhongmin Jin
    Dingjun Hao
    Yonghua Liao
    Sihai Gong
    International Orthopaedics, 2016, 40 : 835 - 841
  • [50] A novel combination of computer-assisted reduction technique and three dimensional printed patient-specific external fixator for treatment of tibial fractures
    Qiao, Feng
    Li, Dichen
    Jin, Zhongmin
    Hao, Dingjun
    Liao, Yonghua
    Gong, Sihai
    INTERNATIONAL ORTHOPAEDICS, 2016, 40 (04) : 835 - 841