Analytical Performance of the Factory-Calibrated Flash Glucose Monitoring System FreeStyle Libre2™ in Healthy Women

被引:6
|
作者
Jin, Zhuoxiu [1 ]
Thackray, Alice E. [1 ,2 ,3 ]
King, James A. [1 ,2 ,3 ]
Deighton, Kevin [4 ]
Davies, Melanie J. [2 ,3 ,5 ]
Stensel, David J. [1 ,2 ,3 ,6 ,7 ]
机构
[1] Loughborough Univ, Natl Ctr Sport & Exercise Med, Sch Sport Exercise & Hlth Sci, Loughborough LE11 3TU, England
[2] Univ Hosp Leicester Natl Hlth Serv NHS Trust, Natl Inst Hlth & Care Res NIHR, Leicester Biomed Res Ctr, Natl Hlth Serv NHS Trust, Leicester LE1 5WW, England
[3] Univ Leicester, Leicester LE1 5WW, England
[4] Nuffield Hlth, Epsom KT18 5AL, Surrey, England
[5] Univ Leicester, Diabet Res Ctr, Leicester LE5 4PW, England
[6] Waseda Univ, Fac Sport Sci, Tokorozawa 3591192, Japan
[7] Chinese Univ Hong Kong, Dept Sports Sci & Phys Educ, Ma Liu Shui, Hong Kong 999077, Peoples R China
关键词
continuous glucose monitoring; blood glucose; agreement; glycaemic dynamics; ASSESSING AGREEMENT;
D O I
10.3390/s23177417
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Continuous glucose monitoring (CGM) is used clinically and for research purposes to capture glycaemic profiles. The accuracy of CGM among healthy populations has not been widely assessed. This study assessed agreement between glucose concentrations obtained from venous plasma and from CGM (FreeStyle Libre2 (TM), Abbott Diabetes Care, Witney, UK) in healthy women. Glucose concentrations were assessed after fasting and every 15 min after a standardized breakfast over a 4-h lab period. Accuracy of CGM was determined by Bland-Altman plot, 15/15% sensor agreement analysis, Clarke error grid analysis (EGA) and mean absolute relative difference (MARD). In all, 429 valid CGM readings with paired venous plasma glucose (VPG) values were obtained from 29 healthy women. Mean CGM readings were 1.14 mmol/L (95% CI: 0.97 to 1.30 mmol/L, p < 0.001) higher than VPG concentrations. Ratio 95% limits of agreement were from 0.68 to 2.20, and a proportional bias (slope: 0.22) was reported. Additionally, 45% of the CGM readings were within +/- 0.83 mmol/L (+/- 15 mg/dL) or +/- 15% of VPG, while 85.3% were within EGA Zones A + B (clinically acceptable). MARD was 27.5% (95% CI: 20.8, 34.2%), with higher MARD values in the hypoglycaemia range and when VPG concentrations were falling. The FreeStyle Libre2 (TM) CGM system tends to overestimate glucose concentrations compared to venous plasma samples in healthy women, especially during hypoglycaemia and during glycaemic swings.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
    Bailey, Timothy
    Bode, Bruce W.
    Christiansen, Mark P.
    Klaff, Leslie J.
    Alva, Shridhara
    DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 (11) : 787 - 794
  • [2] Improved Accuracy of 14-Day Factory-Calibrated FreeStyle Libre System with New Glucose Algorithm
    Karinka, Shridhara Alva
    Bailey, Timothy S.
    Brazg, Ronald L.
    Budiman, Erwin S.
    Castorino, Kristin
    Christiansen, Mark P.
    Liljenquist, David R.
    Liu, Hanqing
    DIABETES, 2019, 68
  • [3] Regarding "The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System," by Bailey et al.
    Weiss, Ray F.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 (03) : 239 - 240
  • [4] Comment on "The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System" by Bailey et al.
    Freckmann, Guido
    Pleus, Stefan
    Schlueter, Sandra
    Heinemann, Lutz
    DIABETES TECHNOLOGY & THERAPEUTICS, 2016, 18 (05) : 334 - 335
  • [5] Response to the Comment on "The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System" by Bailey et al.
    Bailey, Timothy S.
    Alva, Shridhara
    Bode, Bruce W.
    Christiansen, Mark P.
    Klaff, Leslie J.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2016, 18 (05) : 336 - 337
  • [6] Performance of the FreeStyle Libre Flash Glucose Monitoring System during an Oral Glucose Tolerance Test and Exercise in Healthy Adolescents
    Afeef, Sahar
    Tolfrey, Keith
    Zakrzewski-Fruer, Julia K.
    Barrett, Laura A.
    SENSORS, 2023, 23 (09)
  • [7] Analytical Performance of the FreeStyle Libre 2 Glucose Sensor in Healthy Male Adults
    Fellinger, Eva
    Brandt, Tom
    Creutzburg, Justin
    Rommerskirchen, Tessa
    Schmidt, Annette
    SENSORS, 2024, 24 (17)
  • [8] Impact of factory-calibrated Freestyle Libre System with new glucose algorithm measurement accuracy and clinical performance in children with type 1 diabetes during summer camp
    Szadkowska, Agnieszka
    Michalak, Arkadiusz
    Losiewicz, Aleksandra
    Kusmierczyk, Hanna
    Krawczyk-Rusiecka, Kinga
    Chrzanowski, Jedrzej
    Gawrecki, Andrzej
    Zozulinska-Ziolkiewicz, Dorota
    Fendler, Wojciech
    PEDIATRIC DIABETES, 2021, 22 (02) : 261 - 270
  • [9] Performance of the FreeStyle Libre Flash glucose monitoring system in patients with type 1 and 2 diabetes mellitus
    Fokkert, M. J.
    van Dijk, P. R.
    Edens, M. A.
    Abbes, S.
    de Jong, D.
    Slingerland, R. J.
    Bilo, H. J. G.
    BMJ OPEN DIABETES RESEARCH & CARE, 2017, 5 (01):
  • [10] Feasibility of Using a Factory-Calibrated Continuous Glucose Monitoring System to Diagnose Type 2 Diabetes
    Frank, Spencer
    Hames, Kazanna C.
    Jbaily, Abdulrahman
    Park, Jee Hye
    Stroyeck, Chuck
    Price, David
    DIABETES TECHNOLOGY & THERAPEUTICS, 2022, 24 (12) : 907 - 914