Using a 3D Silicon Micro-Channel Device and Raman Spectroscopy for the Analysis of Whole Blood and Abnormal Blood

被引:1
|
作者
Chiang, Chao-Ching [1 ]
Huang, Song-Jeng [1 ]
Immanuel, Philip Nathaniel [1 ]
Lan, Jun-Han [1 ]
Lo, Fang-Yuh [2 ]
Young, Kung-Chia [3 ]
机构
[1] Natl Taiwan Univ Sci & Technol, Dept Mech Engn, Taipei 10607, Taiwan
[2] Natl Taiwan Normal Univ, Dept Phys, Taipei 10611, Taiwan
[3] Natl Cheng Kung Univ, Dept Med Lab Sci & Biotechnol, Tainan 70101, Taiwan
关键词
blood testing; biological information; hemoglobin; Raman spectroscopy; 3D silicon micro-channel device; BETA-CAROTENE; CANCER; SERUM;
D O I
10.3390/mi15010021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Blood testing is a crucial application in the field of clinical studies for disease diagnosis and screening, biomarker discovery, organ function assessment, and the personalization of medication. Therefore, it is of the utmost importance to collect precise data in a short time. In this study, we utilized Raman spectroscopy to analyze blood samples for the extraction of comprehensive biological information, including the primary components and compositions present in the blood. Short-wavelength (532 nm green light) Raman scattering spectroscopy was applied for the analysis of the blood samples, plasma, and serum for detection of the biological characteristics in each sample type. Our results indicated that the whole blood had a high hemoglobin content, which suggests that hemoglobin is a major component of blood. The characteristic Raman peaks of hemoglobin were observed at 690, 989, 1015, 1182, 1233, 1315, and 1562-1649 cm-1. Analysis of the plasma and serum samples indicated the presence of beta-carotene, which exhibited characteristic peaks at 1013, 1172, and 1526 cm-1. This novel 3D silicon micro-channel device technology holds immense potential in the field of medical blood testing. It can serve as the basis for the detection of various diseases and biomarkers, providing real-time data to help medical professionals and patients better understand their health conditions. Changes in biological data collected in this manner could potentially be used for clinical diagnosis.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Analysis of Cell Current with Abnormal Channel Profile in 3D NAND Flash Memory
    Lee, Jaewoo
    Kim, Yungjun
    Shin, Yoocheol
    Park, Seongjo
    Kang, Daewoong
    Kang, Myounggon
    JOURNAL OF SEMICONDUCTOR TECHNOLOGY AND SCIENCE, 2024, 24 (02) : 138 - 143
  • [42] Dopant mapping and strain analysis in B doped silicon structures using micro-Raman spectroscopy
    Bowden, M
    Gardiner, DJ
    Lourenço, MA
    Hedley, J
    Wood, D
    Burdess, JS
    Harris, AJ
    MICROELECTROMECHANICAL STRUCTURES FOR MATERIALS RESEARCH, 1998, 518 : 239 - 244
  • [43] Raman Characterization of Poly-Si Channel Materials for 3D Flash Memory Device Applications
    Yoo, Woo Sik
    Ishigaki, Toshikazu
    Ueda, Takeshi
    Kang, Kitaek
    Sheen, Dong Sun
    Kim, Sung Soon
    Ko, Min Sung
    Shin, Wan Sup
    Kwak, Noh Yeal
    Lee, Byung Seok
    SILICON COMPATIBLE MATERIALS, PROCESSES, AND TECHNOLOGIES FOR ADVANCED INTEGRATED CIRCUITS AND EMERGING APPLICATIONS 4, 2014, 61 (03): : 55 - 61
  • [44] MICROFLUIDIC DEVICE INTEGRATED WITH DEFORMABLE 3D AGPDMS BEAM FOR BLOOD COAGULATION MONITORING
    Li, Tianyi
    Cai, Yao
    Yu, Duli
    Wang, Yuan
    Xing, Xiaoxing
    2022 IEEE 35TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS CONFERENCE (MEMS), 2022, : 876 - 879
  • [45] Label-free 3D analysis of odontogenic differentiation of stem cell spheroids using raman spectroscopy
    Kim, Chang Dae
    Kim, Huijung
    Han, Yoojoong
    Suhito, Intan Rosalina
    Choi, Yoon
    Kwon, Minkyeong
    Kim, Hyung-Ryong
    Son, Hyungbin
    Kim, Tae-Hyung
    TISSUE ENGINEERING PART A, 2022, 28 : 530 - 530
  • [46] Analysis of single blood cells for CSF diagnostics via a combination of fluorescence staining and micro-Raman spectroscopy
    Harz, Michaela
    Kiehntopf, Michael
    Stoeckel, Stephan
    Roesch, Petra
    Deufel, Thomas
    Popp, Juergen
    ANALYST, 2008, 133 (10) : 1416 - 1423
  • [47] Effect of remnant-like lipoprotein particles (RLP) on blood rheology using a micro-channel technique: Studies in patients with fatty liver
    Kurihara, T
    Maeda, A
    Shigemoto, M
    Yamashita, K
    Yokoyama, I
    Nakano, T
    Kawakami, A
    Takagi, Y
    Kikuchi, Y
    ATHEROSCLEROSIS, 1997, 134 (1-2) : 345 - 345
  • [48] Illicit Drug Analysis in Blood Samples with Multivariate Analysis Using Surface-Enhanced Raman Spectroscopy
    Acikgoz, Gunes
    Colak, Abdullah
    SPECTROSCOPY, 2023, 38 : 20 - 27
  • [49] 3D Mapping of Bone Channel of Blood Supply to Femoral Head in Proximal Femur
    Wu, Shenghui
    Quan, Kun
    Wang, Wei
    Zhang, Yingqi
    Mei, Jiong
    FRONTIERS IN SURGERY, 2022, 9
  • [50] Monitoring Time Course of Human Whole Blood Coagulation Using a Microfluidic Dielectric Sensor with a 3D Capacitive Structure
    Maji, Debnath
    Suster, Michael A.
    Stavrou, Evi
    Gurkan, Umut A.
    Mohseni, Pedram