Near-Infrared Spectroscopy for the In Vivo Monitoring of Biodegradable Implants in Rats

被引:1
|
作者
Hassan, Hafiz Wajahat [1 ]
Mota-Silva, Eduarda [2 ,3 ]
Grasso, Valeria [4 ,5 ]
Riehakainen, Leon [2 ,3 ]
Jose, Jithin [4 ]
Menichetti, Luca [2 ]
Mirtaheri, Peyman [1 ]
机构
[1] Oslo Metropolitan Univ, Fac Technol Art & Design, Dept Mech Elect & Chem Engn, N-0130 Oslo, Norway
[2] Natl Res Council IFC CNR, Inst Clin Physiol, I-56124 Pisa, Italy
[3] St Anna Sch Adv Studies, Inst Life Sci, I-56127 Pisa, Italy
[4] FUJIFILM VisualSon, NL-1114 AB Amsterdam, Netherlands
[5] Christian Albrecht Univ Kiel, Inst Mat Sci, Fac Engn, D-24143 Kiel, Germany
关键词
biodegradable implants; in vivo monitoring; Mg alloys; near-infrared spectroscopy (NIRS); oxygen saturation (SO2); photoacoustic imaging (PAI); principal component analysis (PCA); tissue oxygen saturation (StO(2)); OPTICAL-PROPERTIES; OXYGEN-SATURATION; MAGNESIUM ALLOYS; TISSUE; PENETRATION;
D O I
10.3390/s23042297
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Magnesium (Mg) alloys possess unique properties that make them ideal for use as biodegradable implants in clinical applications. However, reports on the in vivo assessment of these alloys are insufficient. Thus, monitoring the degradation of Mg and its alloys in vivo is challenging due to the dynamic process of implant degradation and tissue regeneration. Most current works focus on structural remodeling, but functional assessment is crucial in providing information about physiological changes in tissues, which can be used as an early indicator of healing. Here, we report continuous wave near-infrared spectroscopy (CW NIRS), a non-invasive technique that is potentially helpful in assessing the implant-tissue dynamic interface in a rodent model. The purpose of this study was to investigate the effects on hemoglobin changes and tissue oxygen saturation (StO(2)) after the implantation of Mg-alloy (WE43) and titanium (Ti) implants in rats' femurs using a multiwavelength optical probe. Additionally, the effect of changes in the skin on these parameters was evaluated. Lastly, combining NIRS with photoacoustic (PA) imaging provides a more reliable assessment of tissue parameters, which is further correlated with principal component analysis.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Noninvasive Monitoring of Placental Oxygenation by Near-Infrared Spectroscopy
    Kakogawa, Jun
    Sumimoto, Kazuhiro
    Kawamura, Takakazu
    Minoura, Shigeki
    Kanayama, Naohiro
    AMERICAN JOURNAL OF PERINATOLOGY, 2010, 27 (06) : 463 - 468
  • [32] Evaluation of near-infrared spectroscopy for bioreactor monitoring.
    Rhiel, M
    Riley, MR
    Arnold, MA
    Murhammer, DW
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 213 : 171 - BIOT
  • [33] The role of near-infrared spectroscopy monitoring in preterm infants
    P Korček
    Z Straňák
    J Širc
    G Naulaers
    Journal of Perinatology, 2017, 37 : 1070 - 1077
  • [34] A NEAR-INFRARED SPECTROSCOPY SYSTEM FOR CEREBRAL OXYGENATION MONITORING
    Han, Xue
    Bestonzo, Marco
    Molinari, Filippo
    PROCEEDINGS OF THE 2014 INTERNATIONAL CONFERENCE ON INNOVATIVE DESIGN AND MANUFACTURING (ICIDM), 2014, : 22 - 27
  • [35] SEIZURE MONITORING AND SPEECH LATERALIZATION WITH NEAR-INFRARED SPECTROSCOPY
    EBERHARD, F
    STEFAN, H
    EPILEPSIA, 1995, 36 : S213 - S213
  • [36] Near-infrared spectroscopy for monitoring renal transplant perfusion
    Justin J. Skowno
    Jonathan Saul Karpelowsky
    Pediatric Nephrology, 2014, 29 : 2241 - 2242
  • [37] Monitoring of soybean germination process by near-infrared spectroscopy
    Bartalne-Berceli, M.
    Izso, E.
    Gergely, Sz.
    Salgo, A.
    ACTA ALIMENTARIA, 2022, 51 (02) : 204 - 217
  • [38] Monitoring of methanogen density using near-infrared spectroscopy
    Zhang, YS
    Zhang, ZY
    Sugiura, N
    Maekawa, T
    BIOMASS & BIOENERGY, 2002, 22 (06): : 489 - 495
  • [39] Near-infrared spectroscopy for monitoring renal transplant perfusion
    Skowno, Justin J.
    Karpelowsky, Jonathan Saul
    PEDIATRIC NEPHROLOGY, 2014, 29 (11) : 2241 - 2242
  • [40] Monitoring the secondary structure of proteins by near-infrared spectroscopy
    Robert, P
    Devaux, MF
    Mouhous, N
    Dufour, E
    APPLIED SPECTROSCOPY, 1999, 53 (02) : 226 - 232