Imaging of hypodense gliotic lesions in photon counting computed tomography using virtual monoenergetic images

被引:0
|
作者
Schoenbeck, Denise [1 ,2 ]
Sacha, Alexander [1 ]
Niehoff, Julius Henning [1 ]
Moenninghoff, Christoph [1 ]
Borggrefe, Jan [1 ]
Kroeger, Jan Robert [1 ]
Michael, Arwed Elias [1 ]
机构
[1] Ruhr Univ Bochum, Johannes Wesling Univ Hosp, Dept Radiol Neuroradiol & Nucl Med, Bochum, Germany
[2] Johannes Wesling Univ Hosp, Dept Radiol Neuroradiol & Nucl Med, Muehlenkreisklin, AoR Hans Nolte Str 1, D-32429 Minden, Germany
来源
NEURORADIOLOGY JOURNAL | 2024年 / 37卷 / 03期
关键词
Photon counting computed tomography; photon counting detector; image quality; virtual monoenergetic images; hypodense lesions; BRAIN; CT;
D O I
10.1177/19714009241240056
中图分类号
R445 [影像诊断学];
学科分类号
100207 ;
摘要
Objectives: Glioses appear as hypodense lesions in non-contrast CT examinations of the head. Photon counting CT (PCCT) enables the calculation of virtual monoenergetic images (VMI). The aim of this study is to investigate in which VMI hypodense gliotic lesions can be delineated best. Materials and methods: 35 patients with an MRI-confirmed gliotic lesion and a non-contrast PCCT of the head were retrospectively included. All available VMI from 40 keV to 190 keV were calculated. In a quantitative analysis, conventional image quality parameters were calculated, in particular the contrast-to-noise ratio (CNR) of the hypodense lesion compared to the white matter. In a qualitative analysis, selected VMI were rated by experienced radiologists. Results: The absolute maximum of CNR was 8.12 +/- 5.64 in the VMI 134 keV, in post hoc testing, there were significant differences in comparison to VMI with keV <= 110 and keV >= 180 (corrected p < .05). In the qualitative analysis, there were only very slight differences in the rating of the VMI with 66 keV, 80 keV, 100 keV, and 134 keV with overall low agreement between the readers. Conclusions: The quantitative superiority of VMI 134 keV for the delineation of hypodense gliotic lesions did not translate into a superiority in the qualitative analysis. Therefore, it remains uncertain if the reconstruction of a high keV VMIs for the detection of hypodense gliotic lesions is useful in everyday clinical practice. However, more studies, are necessary to further assess this issue.
引用
收藏
页码:336 / 341
页数:6
相关论文
共 50 条
  • [41] Metal artifact reduction in patients with total hip replacements: evaluation of clinical photon counting CT using virtual monoenergetic images
    Schreck, Julian
    Laukamp, Kai Roman
    Niehoff, Julius Henning
    Michael, Arwed Elias
    Boriesosdick, Jan
    Woeltjen, Matthias Michael
    Kroeger, Jan Robert
    Reimer, Robert P. P.
    Grunz, Jan-Peter
    Borggrefe, Jan
    Lennartz, Simon
    EUROPEAN RADIOLOGY, 2023, 33 (12) : 9286 - 9295
  • [42] Metal artifact reduction in patients with total hip replacements: evaluation of clinical photon counting CT using virtual monoenergetic images
    Julian Schreck
    Kai Roman Laukamp
    Julius Henning Niehoff
    Arwed Elias Michael
    Jan Boriesosdick
    Matthias Michael Wöltjen
    Jan Robert Kröger
    Robert P. Reimer
    Jan-Peter Grunz
    Jan Borggrefe
    Simon Lennartz
    European Radiology, 2023, 33 : 9286 - 9295
  • [43] Assessment of Virtual Monoenergetic Images in Run-off Computed Tomography Angiography: A Comparison Study to Conventional Images From Spectral Detector Computed Tomography
    Ren, Haiyan
    Zhen, Yanhua
    Gong, Zheng
    Wang, Chuanzhuo
    Chang, Zhihui
    Zheng, Jiahe
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2021, 45 (02) : 232 - 237
  • [44] Effect of Virtual Monoenergetic Images From Spectral Detector Computed Tomography on Coronary Calcium Blooming
    Van Hedent, Steven
    Hokamp, Nils Grosse
    Kessner, Rivka
    Gilkeson, Robert
    Ros, Pablo R.
    Gupta, Amit
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (06) : 912 - 918
  • [45] Quantification of airway wall contrast enhancement on virtual monoenergetic images from spectral computed tomography
    Bodenberger, Arndt Lukas
    Konietzke, Philip
    Weinheimer, Oliver
    Wagner, Willi Linus
    Stiller, Wolfram
    Weber, Tim Frederik
    Heussel, Claus Peter
    Kauczor, Hans-Ulrich
    Wielpuetz, Mark Oliver
    EUROPEAN RADIOLOGY, 2023, 33 (08) : 5557 - 5567
  • [46] Quantification of airway wall contrast enhancement on virtual monoenergetic images from spectral computed tomography
    Arndt Lukas Bodenberger
    Philip Konietzke
    Oliver Weinheimer
    Willi Linus Wagner
    Wolfram Stiller
    Tim Frederik Weber
    Claus Peter Heussel
    Hans-Ulrich Kauczor
    Mark Oliver Wielpütz
    European Radiology, 2023, 33 : 5557 - 5567
  • [47] Virtual monoenergetic images from spectral detector computed tomography facilitate washout assessment in arterially hyper-enhancing liver lesions
    R. P. Reimer
    N. Große Hokamp
    A. Fehrmann Efferoth
    A. Krauskopf
    D. Zopfs
    J. R. Kröger
    T. Persigehl
    D. Maintz
    A. C. Bunck
    European Radiology, 2021, 31 : 3468 - 3477
  • [48] Virtual monoenergetic images from spectral detector computed tomography facilitate washout assessment in arterially hyper-enhancing liver lesions
    Reimer, R. P.
    Grosse Hokamp, N.
    Fehrmann Efferoth, A.
    Krauskopf, A.
    Zopfs, D.
    Kroeger, J. R.
    Persigehl, T.
    Maintz, D.
    Bunck, A. C.
    EUROPEAN RADIOLOGY, 2021, 31 (05) : 3468 - 3477
  • [49] Assessment of Photon-Counting Computed Tomography for Quantitative Imaging in Radiation Therapy
    Zimmerman, Jens
    Poludniowski, Gavin
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2025, 121 (05): : 1316 - 1327
  • [50] A review of applications of photon-counting computed tomography in head and neck imaging
    Dogra, Siddhant
    Shekhrajka, Nitesh
    Moonis, Gul
    BRITISH JOURNAL OF RADIOLOGY, 2024,