共 50 条
The Rapid Detection of Salmonella enterica, Listeria monocytogenes, and Staphylococcus aureus via Polymerase Chain Reaction Combined with Magnetic Beads and Capillary Electrophoresis
被引:5
|作者:
Ndraha, Nodali
[1
]
Lin, Hung-Yun
[1
,2
]
Tsai, Shou-Kuan
[3
]
Hsiao, Hsin-, I
[4
]
Lin, Han-Jia
[1
]
机构:
[1] Natl Taiwan Ocean Univ, Dept Biosci & Biotechnol, Keelung 202301, Taiwan
[2] Natl Taiwan Ocean Univ, Ctr Excellence Oceans, Keelung 202301, Taiwan
[3] BiOptic Inc, New Taipei City 23141, Taiwan
[4] Natl Taiwan Ocean Univ, Dept Food Sci, Keelung 202301, Taiwan
来源:
关键词:
food safety;
foodborne detection;
PCR-based method;
nucleic acid amplification;
Salmonella enterica;
Listeria monocytogenes;
Staphylococcus aureus;
FOODBORNE PATHOGENIC BACTERIA;
FOOD-BORNE PATHOGENS;
MULTIPLEX PCR;
ESCHERICHIA-COLI;
SENSITIVE DETECTION;
GAMMA-IRRADIATION;
MEAT;
AMPLIFICATION;
QUALITY;
SAMPLES;
D O I:
10.3390/foods12213895
中图分类号:
TS2 [食品工业];
学科分类号:
0832 ;
摘要:
Food safety concerns regarding foodborne pathogen contamination have gained global attention due to its significant implications. In this study, we developed a detection system utilizing a PCR array combined with an automated magnetic bead-based system and CE technology to enable the detection of three foodborne pathogens, namely Salmonella enterica, Listeria monocytogenes, and Staphylococcus aureus. The results showed that our developed method could detect these pathogens at concentrations as low as 7.3 x 10(1), 6.7 x 10(2), and 6.9 x 10(2) cfu/mL, respectively, in the broth samples. In chicken samples, the limit of detection for these pathogens was 3.1 x 10(4), 3.5 x 10(3), and 3.9 x 10(2) cfu/g, respectively. The detection of these pathogens was accomplished without the necessity for sample enrichment, and the entire protocols, from sample preparation to amplicon analysis, were completed in approximately 3.5 h. Regarding the impact of the extraction method on detection capability, our study observed that an automated DNA extraction system based on the magnetic bead method demonstrated a 10-fold improvement or, at the very least, yielded similar results compared to the column-based method. These findings demonstrated that our developed model is effective in detecting low levels of these pathogens in the samples analyzed in this study. The PCR-CE method developed in this study may help monitor food safety in the future. It may also be extended to identify other foodborne pathogens across a wide range of food samples.
引用
收藏
页数:16
相关论文