Optimal design of tuned inerter negative stiffness dampers with linear viscous and nonlinear eddy current damping for structural effective damping ratio enhancement

被引:8
|
作者
Li, Yafeng [1 ]
Tan, Ping [2 ]
Wang, Siqi [1 ]
Li, Shouying [3 ]
Zhang, Xianxiong [4 ]
机构
[1] Guangzhou Univ, Earthquake Engn Res & Test Ctr, Guangzhou 510006, Peoples R China
[2] Guangzhou Univ, Sch Civil Engn, Guangzhou 510006, Peoples R China
[3] Hunan Univ, Coll Civil Engn, Key Lab Wind & Bridge Engn Hunan Prov, Changsha 410082, Peoples R China
[4] Poly Changda Engn Co Ltd, Guangzhou 510000, Peoples R China
基金
中国国家自然科学基金;
关键词
Tuned inerter negative stiffness damper; Eddy-current-based tuned inerter negative; stiffness damper; Eddy current damping; Effective damping ratio enhancement effect; Damping force limiting characteristic; MASS-DAMPER; EARTHQUAKE PROTECTION; SEISMIC PERFORMANCE; INDUCED VIBRATIONS; FRICTION; MITIGATION; REDUCTION; SYSTEMS;
D O I
10.1016/j.soildyn.2023.108324
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Tuned inerter negative stiffness damper (TINSD) has demonstrated its effectiveness in controlling structural vibrations. However, the potential to improve the effective damping ratio of primary structures remains unexplored, and thus far, TINSD has solely featured linear viscous damping. In this study, we explored two damping types for TINSD: linear viscous damping (abbreviated as TINSD) and nonlinear eddy current damping (termed EC-TINSD). The optimal design of the TINSD was conducted based on the effective damping ratio enhancement (EDRE) effect. Our findings reveal that an increase in the absolute value of the negative stiffness does not result in a continuous improvement in the control efficiency and effectiveness of TINSD, which correspond to the EDRE effect and the structural effective damping ratio, respectively. Importantly, we observe that the proposed optimal TINSD solution outperforms the one derived from the fixed-point method, particularly when the inertance ratio is less than 0.15. For EC-TINSD, its optimal design was performed based on the EDRE effect using statistical linearization techniques that employ both force-based and energy-based equivalent criteria. The control efficiency and effectiveness of optimal EC-TINSD were then validated through Monte Carlo simulation. This analysis highlights the significance of a large critical velocity for EC-TINSD to achieve greater accuracy in vibration control. Numerical studies were further conducted to investigate the control efficiency and effectiveness of ECTINSD under three types of real seismic excitations. The results demonstrate that both TINSD and EC-TINSD exhibit similar effectiveness in mitigating the maximum seismic responses of primary structures, and their efficiency surpasses that of viscous dampers and eddy current dampers with identical damping parameters. Additionally, the distinctive damping force limiting characteristic of EC-TINSD should be commended as it can protect the security and dependability of both the dampers and their connections to the structures.
引用
收藏
页数:15
相关论文
共 23 条
  • [11] Energy dissipation enhancement of nonlinear viscous damping-integrated negative stiffness amplifying dampers
    Zhao, Zhipeng
    Wu, Minjun
    Li, Yixian
    Jiang, Yuan
    Hu, Xiuyan
    Weng, Dagen
    NONLINEAR DYNAMICS, 2025, : 7731 - 7758
  • [12] Effective damping ratio enhancement effect and optimal design of tuned viscous mass damper under seismic excitations
    He H.
    Hao L.-F.
    Tan P.
    You C.-H.
    Xiang Y.
    Zhendong Gongcheng Xuebao/Journal of Vibration Engineering, 2024, 37 (05): : 812 - 821
  • [13] Equivalent damping ratio oriented investigation on tuned negative stiffness inerter damper for seismic application
    He, Hui
    Hao, Linfei
    Zhou, Yun
    Lin, Zicong
    Xiang, Yue
    Li, Yafeng
    JOURNAL OF SOUND AND VIBRATION, 2024, 589
  • [14] Simplified optimal design of MDOF structures with negative stiffness amplifying dampers based on effective damping
    Wang, Meng
    Sun, Fei-fei
    Nagarajaiah, Satish
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2019, 28 (15):
  • [15] Influences of ground motion parameters and structural damping on the optimum design of inerter-based tuned mass dampers
    Zuo, Haoran
    Bi, Kaiming
    Hao, Hong
    Ma, Ruisheng
    ENGINEERING STRUCTURES, 2021, 227
  • [16] First mode damping ratio oriented optimal design procedure for damped outrigger systems with additional linear viscous dampers
    Asai, Tomoki
    Terazawa, Yuki
    Miyazaki, Takashi
    Lin, Pao-Chun
    Takeuchi, Toru
    ENGINEERING STRUCTURES, 2021, 247 (247)
  • [17] Feasibility of eddy current damping-based tuned mass damper inerter for a nonlinear hybrid base-isolated building
    Li, Dawei
    Niu, Chuchu
    Xu, Kangqian
    Han, Jianping
    JOURNAL OF BUILDING ENGINEERING, 2025, 104
  • [18] Effective linear damping and stiffness coefficients of nonlinear systems for design spectrum based analysis
    Giaralis, Agathoklis
    Spanos, Pol D.
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2010, 30 (09) : 798 - 810
  • [19] Simplified Nonlinear Damping Force Formula for Rotary Eddy Current Dampers and Comparative Hazard Analysis under Seismic Excitation with Fluid Viscous Dampers
    Wang, Shuai
    Zhang, Hongyi
    Chen, Zhengqing
    Hua, Xugang
    Feng, Zhouquan
    JOURNAL OF STRUCTURAL ENGINEERING, 2024, 150 (04)
  • [20] Optimal Design of Tuned Mass and Negative Stiffness Amplifier Dampers with Inerter by H2 Optimal Control Under Bidirectional Seismic Load
    Kiran, K. K.
    Al-Osta, Mohammed A.
    Ahmad, Shamsad
    Bahraq, Ashraf A.
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2025, 50 (03) : 1753 - 1783