Potential of Unenhanced Ultra-Low-Dose Abdominal Photon-Counting CT with Tin Filtration: A Cadaveric Study

被引:5
|
作者
Huflage, Henner [1 ]
Grunz, Jan-Peter [1 ]
Patzer, Theresa Sophie [1 ]
Pannenbecker, Pauline [1 ]
Feldle, Philipp [1 ]
Sauer, Stephanie Tina [1 ]
Petritsch, Bernhard [1 ]
Erguen, Sueleyman [2 ]
Bley, Thorsten Alexander [1 ]
Kunz, Andreas Steven [1 ]
机构
[1] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, Oberdurrbacher Str 6, D-97080 Wurzburg, Germany
[2] Univ Wurzburg, Inst Anat & Cell Biol, Koellikerstrasse 6, D-97070 Wurzburg, Germany
关键词
spectral shaping; tin prefiltration; abdominal imaging; ultra-low-dose CT; urinary calculi; photon-counting; IMAGE QUALITY; GUIDELINE; CALCULI; RISKS; STONE;
D O I
10.3390/diagnostics13040603
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: This study investigated the feasibility and image quality of ultra-low-dose unenhanced abdominal CT using photon-counting detector technology and tin prefiltration. Materials and Methods: Employing a first-generation photon-counting CT scanner, eight cadaveric specimens were examined both with tin prefiltration (Sn 100 kVp) and polychromatic (120 kVp) scan protocols matched for radiation dose at three different levels: standard-dose (3 mGy), low-dose (1 mGy) and ultra-low-dose (0.5 mGy). Image quality was evaluated quantitatively by means of contrast-to-noise-ratios (CNR) with regions of interest placed in the renal cortex and subcutaneous fat. Additionally, three independent radiologists performed subjective evaluation of image quality. The intraclass correlation coefficient was calculated as a measure of interrater reliability. Results: Irrespective of scan mode, CNR in the renal cortex decreased with lower radiation dose. Despite similar mean energy of the applied x-ray spectrum, CNR was superior for Sn 100 kVp over 120 kVp at standard-dose (17.75 +/- 3.51 vs. 14.13 +/- 4.02), low-dose (13.99 +/- 2.6 vs. 10.68 +/- 2.17) and ultra-low-dose levels (8.88 +/- 2.01 vs. 11.06 +/- 1.74) (all p <= 0.05). Subjective image quality was highest for both standard-dose protocols (score 5; interquartile range 5-5). While no difference was ascertained between Sn 100 kVp and 120 kVp examinations at standard and low-dose levels, the subjective image quality of tin-filtered scans was superior to 120 kVp with ultra-low radiation dose (p < 0.05). An intraclass correlation coefficient of 0.844 (95% confidence interval 0.763-0.906; p < 0.001) indicated good interrater reliability. Conclusions: Photon-counting detector CT permits excellent image quality in unenhanced abdominal CT with very low radiation dose. Employment of tin prefiltration at 100 kVp instead of polychromatic imaging at 120 kVp increases the image quality even further in the ultra-low-dose range of 0.5 mGy.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Optimization of the Reconstruction Settings for Low-Dose Ultra-High-Resolution Photon-Counting Detector CT of the Lungs
    Graafen, Dirk
    Halfmann, Moritz C.
    Emrich, Tilman
    Yang, Yang
    Kreuter, Michael
    Dueber, Christoph
    Kloeckner, Roman
    Mueller, Lukas
    Jorg, Tobias
    DIAGNOSTICS, 2023, 13 (23)
  • [22] Quantum Iterative Reconstruction for Low-Dose Ultra-High-Resolution Photon-Counting Detector CT of the Lung
    Sartoretti, Thomas
    Racine, Damien
    Mergen, Victor
    Jungblut, Lisa
    Monnin, Pascal
    Flohr, Thomas G.
    Martini, Katharina
    Frauenfelder, Thomas
    Alkadhi, Hatem
    Euler, Andre
    DIAGNOSTICS, 2022, 12 (02)
  • [23] Reduction of Metal Artifacts and Improvement in Dose Efficiency Using Photon-Counting Detector Computed Tomography and Tin Filtration
    Zhou, Wei
    Bartlett, David J.
    Diehn, Felix E.
    Glazebrook, Katrina N.
    Kotsenas, Amy L.
    Carter, Rickey E.
    Fletcher, Joel G.
    McCollough, Cynthia H.
    Leng, Shuai
    INVESTIGATIVE RADIOLOGY, 2019, 54 (04) : 204 - 211
  • [24] Validation of ultra-low-dose unenhanced chest CT for pulmonary arteriovenous malformations diagnostic in hereditary hemorrhagic telangiectasia: a phantom study
    Si-Mohamed, S.
    Dupuis-Girod, S.
    Aurelie, V
    Boccalini, S.
    Mansuy, A.
    Revel, D.
    Douek, P.
    Greffier, J.
    ANGIOGENESIS, 2019, 22 (04) : 616 - 616
  • [25] A Universal Protocol for Abdominal CT Examinations Performed on a Photon-Counting Detector CT System A Feasibility Study
    Zhou, Wei
    Michalak, Gregory J.
    Weaver, Jayse M.
    Gong, Hao
    Yu, Lifeng
    McCollough, Cynthia H.
    Leng, Shuai
    INVESTIGATIVE RADIOLOGY, 2020, 55 (04) : 226 - 232
  • [26] Bone segmentation of the pelvis via tin-filtered ultra-low-dose CT compared with standard CT - A Feasibility Study
    Falkowski, Anna L.
    Carrillo, Fabio
    Novina, Danijel
    Stern, Christoph
    Zingg, Patrick
    Furnstahl, Philipp
    Sutter, Reto
    SWISS MEDICAL WEEKLY, 2021, 151 : 23S - 23S
  • [27] Technical Note: Increased photon starvation artifacts at low helical pitch in ultra-low-dose CT
    Browne, Jacinta E.
    Bruesewitz, Michael R.
    Vrieze, Thomas J.
    McCollough, Cynthia H.
    Yu, Lifeng
    MEDICAL PHYSICS, 2019, 46 (12) : 5538 - 5543
  • [28] Ultra-high resolution photon-counting CT with tin prefiltration for bone-metal interface visualization
    Patzer, Theresa Sophie
    Grunz, Jan-Peter
    Huflage, Henner
    Hennes, Jan-Lucca
    Pannenbecker, Pauline
    Gruschwitz, Philipp
    Afat, Saif
    Herrmann, Judith
    Bley, Thorsten Alexander
    Kunz, Andreas Steven
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 170
  • [29] Reducing contrast media and radiation dose in CT angiography at low tube voltage: animal study with photon-counting detector CT
    Konstantin Klambauer
    Thomas Flohr
    Lukas Jakob Moser
    Victor Mergen
    Matthias Eberhard
    Andreas Prokein
    Hatem Alkadhi
    Hubertus Pietsch
    Gregor Jost
    European Radiology Experimental, 9 (1)
  • [30] Quantitative performance of photon-counting CT at low dose: Virtual monochromatic imaging and iodine quantification
    Vrbaski, Stevan
    Bache, Steve
    Rajagopal, Jayasai
    Samei, Ehsan