Repetitive behavior of an advanced demountable bolted shear connection in push-off tests

被引:10
|
作者
Wang, Wei [1 ]
Zhang, Xie-Dong [1 ]
Chen, Jun [2 ]
Zhou, Xi-Long [3 ]
Zhang, Bai [4 ]
机构
[1] Wuhan Univ Technol, Sch Transportat & Logist Engn, Wuhan 430063, Hubei, Peoples R China
[2] Xiangtan Univ, Coll Civil Engn & Mech, Xiangtan 411105, Hunan, Peoples R China
[3] CCCC Second Highway Consultants Co LTD, Wuhan 430056, Hubei, Peoples R China
[4] Southeast Univ, Key Lab Concrete Prestressed Concrete Struct, Minist Educ, Nanjing 210096, Peoples R China
关键词
Repetitive behavior; Bolt shear connector; Push-off test; Shear capacity; Ductility; PERFORMANCE; STRENGTH;
D O I
10.1016/j.conbuildmat.2022.129656
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Currently, the repetitive behavior of the advanced bolted shear connector embedded in non-shrink self -com-pacting high strength pouring material (HPG) is unclear, restricting its application in steel-concrete composite beams (SCCBs). This study examined the repetitive performance of 21 push-off test specimens using different bolt diameters, bolt loads, loading paths, and loading programs. The failure models, load-slip response, shear bearing resistance, initial slip load, shear stiffness, peak slip, and ductility of this advanced bolted shear connection were evaluated. Bolt shearing off is the typical failure mode for all specimens, along with some concrete crushing underneath the bolts. Under repetitive loading, bolt shear capacity and load-slip response are similar to those under monotonous loading. Peak slip grows with the increase of bolt diameter under repetitive loading compared to monotonic loading. The shear stiffness under repetitive loading is lower than that under monotonic loading and improves with the bolt diameter and the bolt pretension increase. The ductility ratio under repetitive loading is smaller than that under monotonic loading and enlarges with the increase of the bolt diameter. Some design recommendations are proposed based on the existing formulae for predicting this advanced bolted shear connection.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Bolted shear connectors vs. headed studs behaviour in push-out tests
    Pavlovic, Marko
    Markovic, Zlatko
    Veljkovic, Milan
    Budevac, Dragan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2013, 88 : 134 - 149
  • [42] HIGH TEMPERATURE PUSH-OUT TESTS ON DEMOUNTABLE SHEAR CONNECTORS OF STEEL-CONCRETE COMPOSITE BEAMS
    Mansilla, Roberto
    Espinós, Ana
    Payá-Faforteza, Ignacio
    Odenbreit, Christoph
    Romero, Manuel L.
    ce/papers, 2023, 6 (3-4) : 2074 - 2079
  • [43] Push-out tests of demountable headed stud shear connectors in steel-UHPC composite structures
    Wang, Jun-Yan
    Guo, Jun-Yuan
    Jia, Liang-Jiu
    Chen, Shi-Ming
    Dong, Yang
    COMPOSITE STRUCTURES, 2017, 170 : 69 - 79
  • [44] Behavior of high-strength demountable bolted shear connectors in steel-concrete girders with prefabricated slabs
    Fahmy, Ahmed Shamel
    Swelem, Sherine Mostafa
    Abdelaziz, Mohamed Kamal
    ALEXANDRIA ENGINEERING JOURNAL, 2023, 70 : 247 - 260
  • [45] Investigation of Reinforced Concrete Inclined Shear Plane Strengthened by U-Wrapped TRM jacket with Different Anchorage Details using Modified Push-off Tests
    Ngoc Hieu Dinh
    Seung-Hee Kim
    Sang-Hyun Park
    Kyoung-Kyu Choi
    Arabian Journal for Science and Engineering, 2022, 47 : 4003 - 4021
  • [46] Notched connection in timber-concrete composite deck structures: A literature review on push-off experiments & design approaches
    Rasmussen, Peter K.
    Sorensen, Jesper H.
    Hoang, Linh C.
    Feddersen, Bent
    Larsen, Finn
    CONSTRUCTION AND BUILDING MATERIALS, 2023, 397
  • [47] Investigation of Reinforced Concrete Inclined Shear Plane Strengthened by U-Wrapped TRM jacket with Different Anchorage Details using Modified Push-off Tests
    Dinh, Ngoc Hieu
    Kim, Seung-Hee
    Park, Sang-Hyun
    Choi, Kyoung-Kyu
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2022, 47 (04) : 4003 - 4021
  • [48] Push-out tests on bolted shear connectors in composite cold-formed steel beams
    Hosseinpour, Mahmoud
    Zeynalian, Mehran
    Ataei, Abdoreza
    Daei, Maryam
    THIN-WALLED STRUCTURES, 2021, 164
  • [49] Application of push-off shear test for evaluation of wetting-interface structure-bonding relationship of solder joints
    Sobczak, N
    Sobczak, J
    Nowak, R
    Kudyba, A
    Darlak, P
    Mikulowski, B
    Wojciechowski, A
    JOURNAL OF MATERIALS SCIENCE, 2005, 40 (9-10) : 2547 - 2551
  • [50] Application of push-off shear test for evaluation of wetting-interface structure-bonding relationship of solder joints
    N. SOBCZAK
    J. SOBCZAK
    R. NOWAK
    A. KUDYBA
    P. DARLAK
    B. MIKULOWSKI
    A. WOJCIECHOWSKI
    Journal of Materials Science, 2005, 40 : 2547 - 2551