Transcutaneous Spinal Cord Stimulation to Stabilize Seated Systolic Blood Pressure in Persons With Chronic Spinal Cord Injury: Protocol Development

被引:3
|
作者
Peters, Caitlyn G. [1 ,2 ,3 ]
Harel, Noam Y. [1 ,3 ]
Weir, Joseph P. [1 ,4 ]
Wu, Yu-Kuang [1 ,3 ]
Murray, Lynda M. [1 ,3 ]
Chavez, Jorge [1 ,3 ]
Fox, Fiona E. [1 ]
Cardozo, Christopher P. [1 ,3 ]
Wecht, Jill M. [1 ,3 ]
机构
[1] James J Peters VA Med Ctr, 130 West Kingsbridge Rd, Bronx, NY 10468 USA
[2] Kessler Fdn, West Orange, NJ USA
[3] Icahn Sch Med Mt Sinai, New York, NY USA
[4] Univ Kansas, Lawrence, KS USA
来源
NEUROTRAUMA REPORTS | 2023年 / 4卷 / 01期
关键词
autonomic nervous system; blood pressure; electrical stimulation; methodology; spinal cord injury; QUALITY-OF-LIFE; AUTONOMIC CONTROL; INDIVIDUALS; HEALTH; RISK; DYSREGULATION; PERFORMANCE; PRIORITIES; DEMENTIA;
D O I
10.1089/neur.2023.0063
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Transcutaneous spinal cord stimulation (tSCS) is an emerging therapeutic strategy to target spinal autonomic circuitry to normalize and stabilize blood pressure (BP) in hypotensive persons living with chronic spinal cord injury (SCI). Our aim is to describe our current methodological approach to identify individual tSCS parameters that result in the maintenance of seated systolic blood pressure (SBP) within a pre-defined target range. The parent study is a prospective, randomized clinical trial in which eligible participants will undergo multiple mapping sessions to optimize tSCS parameter settings to promote stable SBP within a target range of 110-120 mm Hg for males and 100-120 mm Hg for females. Parameter mapping includes cathode electrode placement site (T7/8, T9/10, T11/12, and L1/2), stimulation frequency (30, 60 Hz), current amplitudes (0-120 mA), waveform (mono- and biphasic), pulse width (1000 mu s), and use of carrier frequency (0, 10 kHz). Each participant will undergo up to 10 mapping sessions involving different electrode placement sites and parameter settings. BP will be continuously monitored throughout each mapping session. Stimulation amplitude (mA) will be increased at intervals of between 2 and 10 mA until one of the following occurs: 1) seated SBP reaches the target range; 2) tSCS intensity reaches 120 mA; or 3) the participant requests to stop. Secondary outcomes recorded include 1) symptoms related to autonomic dysreflexia and orthostatic hypotension, 2) Likert pain scale, and 3) skin appearance after removal of the tSCS electrode.Clinical Trials Registration: NCT05180227
引用
收藏
页码:838 / 847
页数:10
相关论文
共 50 条
  • [21] BLOOD PRESSURE IN SPINAL CORD INJURY
    GOTSHALL, RA
    ARCHIVES OF INTERNAL MEDICINE, 1971, 127 (04) : 775 - &
  • [22] Transcutaneous Electrical Spinal Cord Stimulation Increased Target-Specific Muscle Strength and Locomotion in Chronic Spinal Cord Injury
    Tharu, Niraj Singh
    Wong, Arnold Yu Lok
    Zheng, Yong-Ping
    BRAIN SCIENCES, 2024, 14 (07)
  • [23] Efficacy of Transcutaneous Spinal Stimulation versus Whole Body Vibration for Spasticity Reduction in Persons with Spinal Cord Injury
    Sandler, Evan B.
    Condon, Kyle
    Field-Fote, Edelle C.
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (15)
  • [24] TRANSCUTANEOUS SPINAL CORD STIMULATION TO EFFECT LOWER URINARY TRACT ACTIVITY AFTER SPINAL CORD INJURY
    Kreydin, Evgeniy
    Gad, Parag
    Zhong, Hui
    Latack, Kyle
    Edgerton, V. Reggie
    JOURNAL OF UROLOGY, 2019, 201 (04): : E96 - E96
  • [25] Transcutaneous spinal stimulation as a therapeutic strategy for spinal cord injury: state of the art
    Grecco, Leandro H.
    Li, Shasha
    Michel, Sarah
    Castillo-Saavedra, Laura
    Mourdoukoutas, Andoni
    Bikson, Marom
    Fregni, Felipe
    JOURNAL OF NEURORESTORATOLOGY, 2015, 3 : 73 - 82
  • [26] Transcutaneous spinal cord stimulation on motor function in patients with spinal cord injury: A meta-analysis
    Shi, Changpiao
    Chen, Yi
    Ye, Liang
    Feng, Jun
    Dong, Guoli
    Lu, Shangbo
    NEUROREHABILITATION, 2024, 54 (04) : 563 - 573
  • [27] Transcutaneous spinal cord stimulation to effect lower urinary tract activity after spinal cord injury
    Kreydin, Evgeniy
    Gad, Parag
    Zhong, Hui
    Latack, Kyle
    Edgerton, V. Reggie
    NEUROUROLOGY AND URODYNAMICS, 2019, 38 : S90 - S90
  • [28] Transcutaneous spinal cord stimulation and its impact on cardiovascular autonomic regulation after spinal cord injury
    Solinsky, Ryan
    Burns, Kathryn
    Tuthill, Christopher
    Hamner, Jason W.
    Taylor, J. Andrew
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2024, 326 (01): : H116 - H122
  • [29] Patient-reported effects of transcutaneous spinal cord stimulation on spasticity in patients with spinal cord injury
    Jorgensen, Vivien
    Flaaten, Anne Birgitte
    Ingvarsson, Pall E.
    Lannem, Anne Marie
    JOURNAL OF SPINAL CORD MEDICINE, 2025,
  • [30] The effect of transcutaneous spinal direct current stimulation on corticospinal excitability in chronic incomplete spinal cord injury
    Powell, Elizabeth Salmon
    Carrico, Cheryl
    Salyers, Emily
    Westgate, Philip M.
    Sawaki, Lumy
    NEUROREHABILITATION, 2018, 43 (02) : 125 - 134