Off-design performances of a dry-cooled supercritical recompression Brayton cycle using CO2-H2S as working fluid

被引:7
|
作者
Xu, Zhen [1 ,2 ]
Liu, Xinxin [1 ]
Xie, Yingchun [3 ]
机构
[1] Shandong Univ, Sch Energy & Power Engn, Jinan 250061, Shandong, Peoples R China
[2] Shandong Univ, Shandong Engn Lab High Efficiency Energy Conservat, Jinan 250061, Shandong, Peoples R China
[3] Ocean Univ China, Coll Engn, Qingdao 266100, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
Supercritical recompression brayton cycle; CO2-H2S mixture; Off-design performances; Dry-cooled; CONCENTRATING SOLAR POWER; CO2-BASED BINARY-MIXTURE; CARBON-DIOXIDE; CO2; GENERATION; ENERGY; OPTIMIZATION; LAYOUTS; SYSTEM;
D O I
10.1016/j.energy.2023.127595
中图分类号
O414.1 [热力学];
学科分类号
摘要
The dry-cooled supercritical CO2 recompression Brayton cycle is a promising power generation technology for concentrated solar power plant. Since the critical temperature of working fluid acts as a limitation to heat rejection, H2S can be introduced into pure CO2 to improve the cycle's adaptability to high ambient temperature. The purpose of this study is to recognize the off-design behaviors of the dry-cooled supercritical recompression Brayton cycle using CO2-H2S mixture as working fluid. The detail component models of a 50 MWe power plant as well as the CO2-H2S physical property models are developed. The impacts of heat resource and ambient temperature on cycle performances are evaluated by varying turbine inlet temperature and compressor inlet temperature. The results show that the dry-cooled supercritical CO2-H2S recompression Brayton cycle remains excellent thermodynamic performance even at ambient temperatures up to 50 ?. Under design load, the thermal efficiency decreases by 1.2% points per 5 ? increment in the compressor inlet temperature range of 35 ?-65 ?, and increase 6.4% points when turbine inlet temperature increases from 500 ? to 650 ?. The impact of turbine inlet temperature on split ratio and main shaft speed is lower than that of compressor inlet temperature.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] DESIGN OF A CENTRIFUGAL COMPRESSOR STAGE AND A RADIAL-INFLOW TURBINE STAGE FOR A SUPERCRITICAL CO2 RECOMPRESSION BRAYTON CYCLE BY USING 3D INVERSE DESIGN METHOD
    Zhang, Jiangnan
    Gomes, Pedro
    Zangeneh, Mehrdad
    Choo, Benjamin
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2017, VOL 9, 2017,
  • [42] Performance investigation of a novel closed Brayton cycle using supercritical CO2-based mixture as working fluid integrated with a LiBr absorption chiller
    Ma, Yuegeng
    Liu, Ming
    Yan, Junjie
    Liu, Jiping
    APPLIED THERMAL ENGINEERING, 2018, 141 : 531 - 547
  • [43] Performance optimization of combined supercritical CO2 recompression cycle and regenerative organic Rankine cycle using zeotropic mixture fluid
    Hou, Shengya
    Cao, Sheng
    Yu, Lijun
    Zhou, Yaodong
    Wu, Yuandan
    Zhang, FengYuan
    ENERGY CONVERSION AND MANAGEMENT, 2018, 166 : 187 - 200
  • [44] A numerical investigation of the sCO2 recompression cycle off-design behaviour, coupled to a sodium cooled fast reactor, for seasonal variation in the heat sink temperature
    Floyd, J.
    Alpy, N.
    Moisseytse, A.
    Haubensack, D.
    Rodriguez, G.
    Sienicki, J.
    Avakian, G.
    NUCLEAR ENGINEERING AND DESIGN, 2013, 260 : 78 - 92
  • [45] Molecular dynamics investigation on isobaric heat capacity of working fluid in supercritical CO2 Brayton cycle: Effect of trace gas
    Xue, Juan
    Nie, Xianhua
    Du, Zhenyu
    Li, Hong-Rui
    Zhao, Li
    Zhu, Yu
    Wang, Jiajun
    JOURNAL OF CO2 UTILIZATION, 2022, 55
  • [46] Novel design measures for optimizing the yearlong performance of a concentrating solar thermal power plant using thermal storage and a dry-cooled supercritical CO2 power block
    Ehsan, M. Monjurul
    Guan, Zhiqiang
    Gurgenci, Hal
    Klimenko, Alexander
    ENERGY CONVERSION AND MANAGEMENT, 2020, 216
  • [47] Thermodynamic analysis of CO2-SF6 mixture working fluid supercritical Brayton cycle used for solar power plants
    Bai, Wengang
    Li, Hongzhi
    Zhang, Xuwei
    Qiao, Yongqiang
    Zhang, Chun
    Gao, Wei
    Yao, Mingyu
    ENERGY, 2022, 261
  • [48] THE IMPELLER EXIT FLOW COEFFICIENT AS A PERFORMANCE MAP VARIABLE FOR PREDICTING CENTRIFUGAL COMPRESSOR OFF-DESIGN OPERATION APPLIED TO A SUPERCRITICAL CO2 WORKING FLUID
    Liese, Eric
    Zitney, Stephen E.
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2017, VOL 9, 2017,
  • [49] Parametric study on the effects of a recuperator on the design and off-design performances for a CO2 transcritical power cycle for low temperature geothermal plants
    Wu, Chuang
    Wang, Shun-sen
    Li, Jun
    APPLIED THERMAL ENGINEERING, 2018, 137 : 644 - 658
  • [50] Investigation on the performance of the supercritical Brayton cycle with CO2-based binary mixture as working fluid for an energy transportation system of a nuclear reactor
    Hu, Lian
    Chen, Deqi
    Huang, Yanping
    Li, Le
    Cao, Yiding
    Yuan, Dewen
    Wang, Junfeng
    Pan, Liangming
    ENERGY, 2015, 89 : 874 - 886