Patient-specific cutting guides increase accuracy of medial opening wedge high tibial osteotomy procedure: A retrospective case-control study

被引:3
|
作者
Fayard, Jean-Marie [1 ,4 ]
Saad, Maxime [1 ]
Gomes, Lucas [1 ]
Kacem, Sami [1 ]
Abid, Hichem [1 ]
Vieira, Thais D. [1 ]
Lambrey, Pierre-Jean [1 ]
Ollivier, Matthieu [2 ,3 ]
Thaunat, Mathieu [1 ]
机构
[1] FIFA Med Ctr Excellence, Hop Prive Jean Mermoz, Ctr Orthoped Santy, Ramsay Sante, Lyon, France
[2] Aix Marseille Univ, St Marguer Hosp, APHM, Inst Locomot,Dept Orthoped & Traumatol,CNRS,ISM, Marseille, France
[3] St Marguer Hosp, Inst Movement & Locomot, Dept Orthoped & Traumatol, Marseille, France
[4] FIFA Med Ctr Excellence, Hop Prive Jean Mermoz, Ctr Orthoped Santy, Ramsay Sante, 24 Ave Paul Santy, F-69008 Lyon, France
关键词
3D; medial open-wedge high tibial osteotomy; patient-specific cutting guide; tibial osteotomy accuracy; LIMB ALIGNMENT; COMPARTMENT ARTHRITIS; OPERATIVE TECHNIQUE; CLOSING WEDGE; FOLLOW-UP; KNEE; OSTEOARTHRITIS; NAVIGATION; FIXATION; PLATE;
D O I
10.1002/jeo2.12013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
PurposeTo compare the accuracy of patient-specific guides (PSCG) to the standard technique in medial open-wedge high tibial osteotomy (OWHTO). Secondary objectives were to evaluate factors that could influence accuracy and to compare the complication rate and operating time for both procedures.MethodsA retrospective analysis of prospective collected data was performed. Between March 2011 and May 2018, 49 patients with isolated medial knee osteoarthritis who were operated for OWHTO using PSCG and 38 patients using the standard technique were included. Preoperative and postoperative deformities were evaluated on long leg radiographs by measuring the mechanical medial proximal tibial angle, mechanical lateral distal femoral angle, hip knee ankle angle (HKA), and joint line convergence angle. Pre- and postoperative posterior tibial slope was also evaluated. Accuracy was evaluated by analysing the difference between the preoperative planned and the actual postoperative HKA. Operating time and complication rate were also recorded in both groups.ResultsThe mean preoperative HKA was 173.4 degrees (+/- 3.1 degrees) in the PSCG group and 173.3 degrees (+/- 2.4 degrees) in the standard group (p = 0.8416). Mean planned HKA were 182.8 degrees (+/- 1.1 degrees) and 184.0 degrees (+/- 0 degrees) respectively for the PSCG and the standard group. Mean postoperative HKA were 181.9 degrees (+/- 1.9 degrees) and 182.6 degrees (+/- 3.1 degrees) respectively for the PSCG and the standard group. An accuracy of +/- 2 degrees in the HKA was achieved in 44 (90%) in the PSCG group and 24 (65%) in the standard group (p = 0.006). The probability of achieving a HKA accuracy was four times higher for patients in the PSCG group (odds ratio [OR] = 4.06, [1.1; 15.3], p = 0.038). Also, higher preoperative Ahlback grade was associated with precision, all other parameters being equal (OR = 4.2, [0.13; 0.97], p = 0.04).ConclusionIn this study, the PSCG technique was significantly more accurate for achieving the planned HKA in OWHTO. Complication rates and operating times were comparable between groups.Level of EvidenceLevel IV, case-control study.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Patient-specific instrumentation for medial opening wedge high tibial osteotomies in the management of medial compartment osteoarthritis yields high accuracy and low complication rates: A systematic review
    Dasari, Suhas P.
    Hevesi, Mario
    Mameri, Enzo
    Ferrer-Rivero, Robert
    Fortier, Luc M.
    Jackson, Garrett R.
    Warrier, Alec A.
    Maheshwer, Bhargavi
    Jawanda, Harkirat
    Khan, Zeeshan A.
    Kerzner, Benjamin
    Browning, Robert B.
    Gursoy, Safa
    Chahla, Jorge
    JOURNAL OF ISAKOS JOINT DISORDERS & ORTHOPAEDIC SPORTS MEDICINE, 2023, 8 (03) : 163 - 176
  • [22] Minimally Invasive High Tibial Osteotomy Using a Patient-Specific Cutting Guide
    Bin Abd Razak, Hamid Rahmatullah
    Jacquet, Christophe
    Wilson, Adrian J.
    Khakha, Raghbir S.
    Kley, Kristian
    Parratte, Sebastien
    Ollivier, Matthieu
    ARTHROSCOPY TECHNIQUES, 2021, 10 (02): : e431 - e435
  • [23] A new three-dimensional patient-specific cutting guide for opening wedge high tibial osteotomy based on ct scan: preliminary in vitro results
    Federica Rosso
    Roberto Rossi
    Philippe Neyret
    Robert Śmigielski
    Jacques Menetrey
    Davide Edoardo Bonasia
    Sandro Franco Fucentese
    Journal of Experimental Orthopaedics, 10
  • [24] A new three-dimensional patient-specific cutting guide for opening wedge high tibial osteotomy based on ct scan: preliminary in vitro results
    Rosso, Federica
    Rossi, Roberto
    Neyret, Philippe
    Smigielski, Robert
    Menetrey, Jacques
    Bonasia, Davide Edoardo
    Fucentese, Sandro Franco
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2023, 10 (01)
  • [25] Patient-specific cutting guides allow 1° precision in asymmetric anterior closing-wedge osteotomy
    Leluc, Julien
    Mabrouk, Ahmed
    Hirth, Jacob
    Nawabi, Danyal
    Jacquet, Christophe
    Ollivier, Matthieu
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2025, 12 (01)
  • [26] Three dimensional patient-specific printed cutting guides for closing-wedge distal femoral osteotomy
    JianHui Shi
    Wei Lv
    Yan Wang
    Ben Ma
    Wei Cui
    ZhenZhong Liu
    KeCheng Han
    International Orthopaedics, 2019, 43 : 619 - 624
  • [27] Effect of posteriorly inclined sagittal osteotomy on posterior tibial slope in biplanar medial opening wedge high tibial osteotomy: a case series study
    Oktem, Umut
    Dedeogullari, Emin Suha
    Bingol, Izzet
    Kamaci, Saygin
    Bozkurt, Ibrahim
    Ocguder, Durmus Ali
    BMC MUSCULOSKELETAL DISORDERS, 2025, 26 (01)
  • [28] Can three-dimensional patient-specific cutting guides be used to achieve optimal correction for high tibial osteotomy? Pilot study
    Munier, M.
    Donnez, M.
    Ollivier, M.
    Flecher, X.
    Chabrand, P.
    Argenson, J. -N.
    Parratte, S.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (02) : 245 - 250
  • [29] Three dimensional patient-specific printed cutting guides for closing-wedge distal femoral osteotomy
    Shi, JianHui
    Lv, Wei
    Wang, Yan
    Ma, Ben
    Cui, Wei
    Liu, ZhenZhong
    Han, KeCheng
    INTERNATIONAL ORTHOPAEDICS, 2019, 43 (03) : 619 - 624
  • [30] Combined Medial Meniscus Allograft Transplantation and Open-Wedge High Tibial Osteotomy Using a Patient-Specific Instrumentation Guide
    Aubret, Sylvain
    Ngbilo, Cedric
    Winkler, Michaela
    Neyret, Brigitte
    Ouabo, Eric Choudja
    ARTHROSCOPY TECHNIQUES, 2022, 11 (12): : E2279 - E2288