Diagnostic accuracy of superb microvascular imaging for detecting intraplaque neovascularization: a systematic review and meta-analysis

被引:2
|
作者
Zhao, Lina [1 ]
Han, Yubo [1 ]
Che, Yanling [1 ]
Zhang, Xuesong [1 ]
Luo, Min [1 ]
Li, Jinzhu [2 ]
机构
[1] Heilongjiang Univ Chinese Med, Affiliated Hosp 1, Dept Ultrasound Med, Harbin, Peoples R China
[2] Second Hosp Heilongjiang Prov, Dept Ultrasound Med, Harbin, Peoples R China
基金
中国国家自然科学基金;
关键词
Superb microvascular imaging (SMI); contrast-enhanced carotid ultrasonography (CEUS); carotid plaque; diagnostic accuracy; systematic review; CONTRAST-ENHANCED ULTRASOUND; STROKE RISK; SPECIFICITY; SENSITIVITY; PLAQUE; RATIO;
D O I
10.21037/cdt-23-202
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Atherosclerotic plaques can cause carotid artery stenosis, and "vulnerable plaques" can even lead to ischemic stroke. The objective of this study was to assess the accuracy of superb microvascular imaging (SMI) for the detection of carotid intraplaque neovascularization (IPN) in patients with atherosclerotic plaques. Methods: We searched the Cochrane Library, Embase, Medline, and Wanfang databases until January 17, 2023. We included original studies with information on diagnostic accuracy of SMI for the evaluation of carotid IPN. The primary outcome was the accuracy of SMI for detecting carotid IPN. A meta-analysis was performed to estimate the accuracy of each parameter. We used the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) to assess the risk of bias for each included article. Meta-regression was performed to determine items that may have contributed to heterogeneity in the sensitivity or specificity of the test. Results: This meta-analysis included 20 studies with 1,589 carotid plaques in 1,225 patients. The analysis showed a sensitivity and specificity of SMI for detecting IPN of 93% [95% confidence interval (CI): 87- 96%] and 80% (95% CI: 71-87%), respectively. The risk of bias across the QUADAS-2 domains was low. Only the proportion of dyslipidemia influenced the estimates of sensitivity and specificity. Conclusions: This review suggests that SMI has a good diagnostic performance for detecting carotid IPN. The very high sensitivity with excellent post-test probability indicated that SMI can be recommended to screen for carotid IPN among patients with carotid plaques.
引用
收藏
页码:893 / 905
页数:15
相关论文
共 50 条
  • [21] Diagnostic Accuracy of Sonoelastography in Detecting Malignant Thyroid Nodules: A Systematic Review and Meta-Analysis
    Ghajarzadeh, Mahsa
    Sodagari, Faezeh
    Shakiba, Madjid
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 202 (04) : W379 - W389
  • [22] Diagnostic Accuracy of EUS in Detecting Pancreatic Neuroendocrine Tumors: A Meta-Analysis and Systematic Review
    Puli, Srinivas R.
    Bechtold, Matthew L.
    Reddy, Jyotsna B. K.
    Bapoje, Srinivas R.
    Antillon, Mainor R.
    Brugge, William R.
    GASTROENTEROLOGY, 2009, 136 (05) : A932 - A932
  • [23] Diagnostic accuracy of intracranial translucency in detecting spina bifida: a systematic review and meta-analysis
    Maruotti, Giuseppe M.
    Saccone, Gabriele
    D'Antonio, Francesco
    Berghella, Vincenzo
    Sarno, Laura
    Morlando, Maddalena
    Giudicepietro, Antonia
    Martinelli, Pasquale
    PRENATAL DIAGNOSIS, 2016, 36 (11) : 991 - 996
  • [24] Diagnostic accuracy of artificial intelligence in detecting retinitis pigmentosa: A systematic review and meta-analysis
    Musleh, Ayman Mohammed
    AlRyalat, Saif Aldeen
    Abid, Mohammad Naim
    Salem, Yahia
    Hamila, Haitham Mounir
    Sallam, Ahmed B.
    SURVEY OF OPHTHALMOLOGY, 2024, 69 (03) : 411 - 417
  • [25] Diagnostic Accuracy of Ambulatory Devices in Detecting Atrial Fibrillation: Systematic Review and Meta-analysis
    Yang, Tien Yun
    Huang, Li
    Malwade, Shwetambara
    Hsu, Chien-Yi
    Chen, Yang Ching
    JMIR MHEALTH AND UHEALTH, 2021, 9 (04):
  • [26] Diagnostic accuracy of ultrasound signs for detecting adnexal torsion: systematic review and meta-analysis
    Garde, I.
    Paredes, C.
    Ventura, L.
    Pascual, M. A.
    Ajossa, S.
    Guerriero, S.
    Vara, J.
    Linares, M.
    Alcazar, J. L.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2023, 61 (03) : 310 - 324
  • [27] Diagnostic accuracy of functional imaging modalities for chondrosarcoma: A systematic review and meta-analysis
    Jo, I
    Gould, D.
    Schlicht, S.
    Taubman, K.
    Choong, P.
    JOURNAL OF BONE ONCOLOGY, 2019, 19
  • [28] Diagnostic Accuracy of Imaging Findings in Pleural Empyema: Systematic Review and Meta-Analysis
    Zettinig, Desiree
    D'Antonoli, Tugba Akinci
    Wilder-Smith, Adrian
    Bremerich, Jens
    Roth, Jan A.
    Sexauer, Raphael
    JOURNAL OF IMAGING, 2022, 8 (01)
  • [29] The accuracy of diagnostic imaging for the assessment of chronic osteomyelitis; Systematic review and meta-analysis
    Termaat, MF
    Raijmakers, PGH
    Scholten, HJ
    Patka, P
    Bakker, FC
    Haarman, HJT
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S276 - S277
  • [30] Diagnostic accuracy of deep learning in medical imaging: a systematic review and meta-analysis
    Aggarwal, Ravi
    Sounderajah, Viknesh
    Martin, Guy
    Ting, Daniel S. W.
    Karthikesalingam, Alan
    King, Dominic
    Ashrafian, Hutan
    Darzi, Ara
    NPJ DIGITAL MEDICINE, 2021, 4 (01)