Risk Factors for the Drift Phenomenon in O-arm Navigation-Assisted Pedicle Screw Placement during Spinal Deformity Surgery

被引:3
|
作者
Zhao, Jianquan [1 ]
Jiang, Heng [1 ]
Zhuge, Yingjie [2 ]
Gao, Rui [1 ]
Wang, Ce [1 ]
Ma, Jun [1 ]
Zhou, Xuhui [1 ]
机构
[1] Second Mil Med Univ, Shanghai Changzheng Hosp, Dept Orthopaed Surg, Shanghai 200003, Peoples R China
[2] Shanghai Jiao Tong Univ, Shanghai Peoples Hosp 6, Dept Orthopaed Surg, Shanghai, Peoples R China
关键词
Deformity; Drift phenomenon; Navigation; O-arm; Pedicle screw; ANTERIOR VERTEBRAL HEIGHT; FREE-HAND; FRACTURED VERTEBRA; ACCURACY; SCOLIOSIS; RESTORATION; FLUOROSCOPY; INSERTION; FIXATION; SAFETY;
D O I
10.1111/os.13557
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective Intraoperative O-arm navigation systems improve the accuracy of spinal instrumentation placement. However, deviation of the pedicle screw from the guide line might occur. The aim of the present study was to explore the causes of and countermeasures for the drift phenomenon during pedicle screw implantation with the aid of an O-arm three-dimensional navigation system in spinal deformity surgery. Methods This was a retrospective analysis of 341 patients with spinal deformity who underwent O-arm navigation system-assisted pedicle screw placement from July 2015 to June 2019. The patient's general condition, Cobb angle, apical vertebra position, softness index, spinal release status, fixed reference frame position, and distance between the navigation vertebral body and the reference frame were collected and compared by independent-samples t test or Pearson's chi-square analysis. The potential risk factors for the drift phenomenon were identified using binary logistic regression analysis. Results The drift phenomenon occurred in 57 patients during the first navigation-assisted pedicle screw placement, for an incidence of 16.7% (57/341). There were significant differences in factors such as the apical vertebra position, softness index, spinal release status, and distance between the vertebral body and the reference frame when the drift phenomenon occurred (P < 0.05). Binary logistic regression analysis showed that the softness index, spinal release status, and distance between the vertebral body and the reference frame when drifting occurred were independent risk factors for the drift phenomenon during O-arm navigation-assisted pedicle screw placement. Conclusion During the use of an O-arm navigation system to assist with pedicle screw placement, pedicle screws should not be placed away from the reference frame, and spinal osteotomy and release should be performed after pedicle screw placement. In addition, the accuracy of O-arm navigation-assisted pedicle screw placement will be affected more in those with larger softness indices.
引用
收藏
页码:118 / 123
页数:6
相关论文
共 50 条
  • [21] Comparison of the Accuracy of Pedicle Screw Placement Using a Fluoroscopy-Assisted Free-Hand Technique with Robotic-Assisted Navigation Using an O-Arm or 3D C-Arm in Scoliosis Surgery
    Li, Chao
    Li, Hao
    Su, Junxiao
    Wang, Zheng
    Li, Donglai
    Tian, Yonghao
    Yuan, Suomao
    Wang, Lianlei
    Liu, Xinyu
    GLOBAL SPINE JOURNAL, 2024, 14 (04) : 1337 - 1346
  • [22] One-step Minimally Invasive Pedicle Screw Instrumentation Using O-Arm and Stealth Navigation
    Kleck, Christopher J.
    Johnson, Christopher
    Akiyama, Michelle
    Burger, Evalina L.
    Cain, Christopher J.
    Patel, Vikas V.
    CLINICAL SPINE SURGERY, 2018, 31 (05): : 197 - 202
  • [23] A Prospective Multicenter Registry on the Accuracy of Pedicle Screw Placement in the Thoracic, Lumbar, and Sacral Levels With the Use of the O-arm Imaging System and StealthStation Navigation
    Van de Kelft, Erik
    Costa, F.
    Van der Planken, D.
    Schils, F.
    SPINE, 2012, 37 (25) : E1580 - E1587
  • [24] ROBOTIC-ASSISTED PEDICLE SCREW PLACEMENT DURING SPINE SURGERY
    Lieberman, Isador H.
    Kisinde, Stanley
    Hesselbacher, Shea
    JBJS ESSENTIAL SURGICAL TECHNIQUES, 2020, 10 (02):
  • [25] Novel Applications of Spinal Navigation in Deformity and Oncology Surgery-Beyond Screw Placement
    Massaad, Elie
    Shankar, Ganesh M.
    Shin, John H.
    OPERATIVE NEUROSURGERY, 2021, 21 : S23 - S38
  • [26] Intraoperative 3-dimensional imaging (O-arm) for assessment of pedicle screw position: Does it prevent unacceptable screw placement?
    Sembrano, Jonathan N.
    Polly, David W., Jr.
    Ledonio, Charles Gerald T.
    Santos, Edward Rainier G.
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2012, 6 : 49 - 54
  • [27] Computer Navigation-Assisted Spinal Fusion with Segmental Pedicle Screw Instrumentation for Scoliosis with Rett Syndrome: A Case Report
    Tanaka, Masato
    Nakanishi, Kazuo
    Sugimoto, Yoshihisa
    Misawa, Haruo
    Takigawa, Tomoyuki
    Nishida, Keiichiro
    Ozaki, Toshifumi
    ACTA MEDICA OKAYAMA, 2009, 63 (06) : 373 - 377
  • [28] Incidence and risk factors for the misplacement of pedicle screws in scoliosis surgery assisted by O-arm navigation—analysis of a large series of one thousand, one hundred and forty five screws
    Mengran Jin
    Zhen Liu
    Yong Qiu
    Huang Yan
    Xiao Han
    Zezhang Zhu
    International Orthopaedics, 2017, 41 : 773 - 780
  • [29] Safety and Accuracy of Freehand Pedicle Screw Placement and the Role of Intraoperative O-Arm A Single-Institution Experience
    Alomari, Safwan
    Lubelski, Daniel
    Lehner, Kurt
    Tang, Anthony
    Wolinsky, Jean-Paul
    Theodore, Nicholas
    Sciubba, Daniel M.
    Lo, Sheng-fu Larry
    Belzberg, Allan
    Weingart, Jon
    Witham, Timothy
    Gokaslan, Ziya L.
    Bydon, Ali
    SPINE, 2023, 48 (03) : 180 - 188
  • [30] Comparison of the Wiltse Approach and Percutaneous Pedicle Screw Fixation Under O-arm Navigation for the Treatment of Thoracolumbar Fractures
    Lu, Ying-jie
    Miao, Yi-ming
    Zhu, Tian-feng
    Wu, Qian
    Shen, Xu
    Lu, Dong-dong
    Zhu, Xue-song
    Gan, Min-feng
    ORTHOPAEDIC SURGERY, 2021, 13 (05) : 1618 - 1627