Contactless Sensing of Water Properties for Smart Monitoring of Pipelines

被引:8
|
作者
Riboldi, Christian [1 ]
Castillo, Danilo A. Carnevale [1 ]
Crafa, Daniele M. [1 ]
Carminati, Marco [1 ,2 ]
机构
[1] Politecn Milan, Dipartimento Elettron, Informaz & Bioingn, I-20133 Milan, Italy
[2] Sez Milano, Ist Nazl Fis Nucleare INFN, I-20133 Milan, Italy
关键词
ultrasonic flow meter; impedance; lock-in amplifier; wireless sensors networks; internet of things; pipe retrofitting; drinking water; water grid monitoring; VELOCITY-MEASUREMENT; DATA FUSION; SENSOR; SLUG;
D O I
10.3390/s23042075
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A key milestone for the pervasive diffusion of wireless sensing nodes for smart monitoring of water quality and quantity in distribution networks is the simplification of the installation of sensors. To address this aspect, we demonstrate how two basic contactless sensors, such as piezoelectric transducers and strip electrodes (in a longitudinal interdigitated configuration to sense impedance inside and outside of the pipe with potential for impedimetric leak detection), can be easily clamped on plastic pipes to enable the measurement of multiple parameters without contact with the fluid and, thus, preserving the integrity of the pipe. Here we report the measurement of water flow rate (up to 24 m(3)/s) and temperature with ultrasounds and of the pipe filling fraction (capacitance at 1 MHz with similar to cm(3) resolution) and ionic conductivity (resistance at 20 MHz from 700 to 1400 mu S/cm) by means of impedance. The equivalent impedance model of the sensor is discussed in detail. Numerical finite-element simulations, carried out to optimize the sensing parameters such as the sensing frequency, confirm the lumped models and are matched by experimental results. In fact, a 6 m long, 30 L demonstration hydraulic loop was built to validate the sensors in realistic conditions (water speed of 1 m/s) monitoring a pipe segment of 0.45 m length and 90 mm diameter (one of the largest ever reported in the literature). Tradeoffs in sensors accuracy, deployment, and fabrication, for instance, adopting single-sided flexible PCBs as electrodes protected by Kapton on the external side and experimentally validated, are discussed as well.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] A Smart Sensing Unit for Vibration Measurement and Monitoring
    Wang, Wilson
    Jianu, Ofelia Antonia
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2010, 15 (01) : 70 - 78
  • [22] Design of smart sensing components for volcano monitoring
    Xu, Mingsen
    Song, Wen-Zhan
    Huang, Renjie
    Peng, Yang
    Shirazi, Behrooz
    Lahusen, Richard
    Kiely, Aaron
    Peterson, Nina
    Ma, Andy
    Anusuya-Rangappa, Lohith
    Miceli, Michael
    McBride, Devin
    PERVASIVE AND MOBILE COMPUTING, 2009, 5 (05) : 639 - 653
  • [23] Smart lanthanide antennas for sensing water
    Fueyo-Gonzalez, Francisco
    Garcia-Fernandez, Emilio
    Martinez, David
    Infantes, Lourdes
    Orte, Angel
    Gonzalez-Vera, Juan A.
    Herranz, Rosario
    CHEMICAL COMMUNICATIONS, 2020, 56 (41) : 5484 - 5487
  • [24] A Contactless Method for Testing Inner Walls of Pipelines
    V. V. Davydov
    N. S. Myazin
    S. E. Logunov
    V. B. Fadeenko
    Russian Journal of Nondestructive Testing, 2018, 54 : 213 - 221
  • [25] Contactless Medical Sensing
    Schreurs, Dominique
    Mercuri, Marco
    2015 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM (IMS), 2015,
  • [27] A Contactless Method for Testing Inner Walls of Pipelines
    Davydov, V. V.
    Myazin, N. S.
    Logunov, S. E.
    Fadeenko, V. B.
    RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING, 2018, 54 (03) : 213 - 221
  • [28] Transducers for contactless induction inspections of underground pipelines
    Drabich, PP
    MEASUREMENT TECHNIQUES USSR, 1995, 38 (04): : 454 - 458
  • [29] Contactless smart card IC
    不详
    AMERICAN CERAMIC SOCIETY BULLETIN, 2002, 81 (12): : 16 - 16
  • [30] Smart Water Monitoring Reach Extension
    Pinney, Dan