Open circuit fault diagnosis for a five-level neutral point clamped inverter in a grid-connected photovoltaic system with hybrid energy storage system

被引:1
|
作者
Abdellah, A. [1 ]
Larbi, M. [1 ]
Toumi, D. [1 ]
机构
[1] Univ Tiaret, Dept Elect Engn, Lab L2GEGI, Tiaret, Algeria
关键词
photovoltaic; fault diagnosis; five-level neutral point clamped inverter; line-to-line pole voltages; BATTERY; CONVERTERS; ALGORITHM; STRATEGY; DRIVES;
D O I
10.20998/2074-272X.2023.6.06
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Introduction. Recently, the number of high and medium voltage applications has increased dramatically. The connection between these different applications requires series-parallel combinations of power semiconductors. Multilevel converter topologies provide major advantages to these applications. In this paper, a grid-connected photovoltaic system with a hybrid energy storage system using a five-level neutral point clamped inverter is studied. Although the multilevel inverter has many advantages over the two-level inverter, it has a high probability of experiencing an open circuit fault. In this context, the five-level inverter has 24 controllable switches, one of which may experience an open circuit fault at any time. Therefore, it plays an important part in the reliability and robustness of the whole system. The novelty of this paper presents an approach to accurately detect the open circuit fault in all insulated gate bipolar transistors of a five-level neutral point clamped inverter in a photovoltaic power generation application with a hybrid energy storage system. Purpose. Before using fault-tolerant control to ensure service continuity, fault diagnosis techniques must first be used, which are the crucial phase of reliability. Methods. A detection method based on the maximum and minimum error values is proposed. These errors are calculated using the expected and measured line-to-line pole voltages. Results. The open circuit fault detection method is implemented using MATLAB/Simulink. Simulation results showed the accuracy of detecting the open circuit fault in all insulated gate bipolar transistors in a short time. Moreover, this method is adaptable to several applications and is also robust to transient regimes imposed by solar irradiation and load variations. References 26, table 3, figures 16.
引用
收藏
页码:33 / 40
页数:8
相关论文
共 50 条
  • [41] Transformerless Split-Inductor Neutral Point Clamped Three-Level PV Grid-Connected Inverter
    Xiao, Huafeng
    Xie, Shaojun
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (04) : 1799 - 1808
  • [42] Fault Tolerance Analysis of Five-Level Neutral-Point-Clamped Inverters under Clamping Diode Open-Circuit Failure
    Ahmadi, Sajjad
    Poure, Philippe
    Saadate, Shahrokh
    Khaburi, Davood Arab
    ELECTRONICS, 2022, 11 (09)
  • [43] Transformerless Split-inductor Neutral point clamped Three-level PV Grid-Connected Inverter
    Xiao, Huafeng
    Xie, Shaojun
    Yang, Chen
    2010 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, 2010, : 2929 - 2936
  • [44] A 5-level High Efficiency Low Cost Hybrid Neutral Point Clamped Transformerless Inverter for Grid Connected Photovoltaic Application
    Kadam, Abhijit
    Shukla, Anshuman
    THIRTY-THIRD ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2018), 2018, : 3189 - 3194
  • [45] Grid-Connected Photovoltaic System: Optimization of the Inverter Size Using an Energy Approach
    Notton, G.
    Lazarov, V.
    Stoyanov, L.
    Heraud, N.
    2009 8TH INTERNATIONAL SYMPOSIUM ON ADVANCED ELECTROMECHANICAL MOTION SYSTEMS (ELECTROMOTION 2009), 2009, : 313 - +
  • [46] Performance Evaluation of Grid-Connected Photovoltaic System with Battery Energy Storage
    Daud, M. Z.
    Mohamed, A.
    Wanik, M. Z. Che
    Hannan, M. A.
    2012 IEEE INTERNATIONAL CONFERENCE ON POWER AND ENERGY (PECON), 2012, : 337 - 342
  • [47] Modern grid-connected photovoltaic power system with energy storage element
    Szymanski, Bernard
    Kompa, Kamil
    Roslaniec, Lukasz
    Dmowski, Antoni
    PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (09): : 298 - 301
  • [48] Advanced Control for Grid-Connected System With Coordinated Photovoltaic and Energy Storage
    Zhu, Yujie
    Chen, Guanhua
    FRONTIERS IN ENERGY RESEARCH, 2022, 10
  • [49] Control of Five-level Flying Capacitor Based Active-Neutral-Point-Clamped Converter for Grid Connected Wind Energy Applications
    Pulikanti, Sridhar R.
    Muttaqi, Kashem
    Suntanto, Danny
    2012 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING (IAS), 2012,
  • [50] Study of a new DC voltage equalising circuit for Five-Level Neutral Point Clamped-Voltage Source Inverter
    Chibani, Redha.
    Berkouk, ElMadjid.
    Boucherit, Mohamed Seghir.
    JOURNAL OF ELECTRICAL SYSTEMS, 2011, 7 (02) : 131 - 148