Initial experience of temperature-controlled irrigated radiofrequency ablation for ischaemic cardiomyopathy ventricular tachycardia ablation

被引:6
|
作者
Al-Sheikhli, Jaffar [1 ]
Patchett, Ian [1 ]
Lim, Ven Gee [1 ]
Marshall, Leeann [1 ]
Foster, Will [1 ]
Kuehl, Michael [1 ,2 ]
Yusuf, Shamil [1 ]
Panikker, Sandeep [1 ]
Patel, Kiran [1 ,2 ]
Osman, Faizel [1 ,2 ]
Banerjee, Prithwish [1 ,2 ]
Lellouche, Nicolas [3 ,4 ]
Dhanjal, Tarvinder [1 ,2 ]
机构
[1] Univ Hosp Coventry & Warwickshire NHS Trust, Dept Cardiol, Coventry, W Midlands, England
[2] Univ Warwick, Coventry, W Midlands, England
[3] Hop Henri Mondor Albert Chenevier, Ave Marechal de Lattre de Tassigny, Creteil, France
[4] INSERM, U955, F-94000 Paris, France
关键词
Ventricular tachycardia; Ischaemic cardiomyopathy; Temperature-controlled irrigated radiofrequency ablation; Feasibility; PULMONARY VEIN ISOLATION; CATHETER ABLATION; IMPEDANCE;
D O I
10.1007/s10840-022-01158-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The DiamondTemp ablation (DTA) catheter system delivers high power, open-irrigated, temperature-controlled radiofrequency (RF) ablation. This novel ablation system has not been previously used for ventricular tachycardia (VT) ablation. Objective Feasibility of using the DTA catheter system for VT ablation in ischaemic cardiomyopathy (ICM) patients. Method Ten ICM patients with optimal anti-arrhythmic drug therapy and implantable cardiac defibrillators (ICD) were recruited. VT inducibility testing was performed at the end of the procedure. ICD data for device detected VT episodes and device treated VT episodes were collected for 6-months pre- and post-ablation. Results Substrate analysis demonstrated reductions in the borderzone area of 4.4 cm(2) (p = 0.026) and late potential area of 3.5 cm(2) (p = 0.0449) post-ablation, with reductions in the mean bipolar and unipolar voltages of the ablation target areas (0.14 mV (p = 0.0007); 0.59 mV (p = 0.0072) respectively). Complete procedural success was achieved in 9 procedures. Post-ablation VT inducibility testing was not performed in 1 procedure due to a steam pop complication resulting in pericardial tamponade requiring drainage. Mean follow-up of 214 +/- 33 days revealed an 88% reduction in total VT episodes (n = 266 median 16 [IQR 3-57] to n = 33 median 0; p = 0.0164) and 77% reduction in ICD therapies (n = 128 median 5 [IQR 2-15] to n = 30 median 0; p = 0.0181). Conclusion The DTA system resulted in adequate lesion characteristics with effective substrate modification, acute procedural success and improved outcomes at intermediate-term follow-up. Randomised controlled trials are required to compare the performance of the DTA system against conventional ablation catheters.
引用
收藏
页码:551 / 559
页数:9
相关论文
共 50 条
  • [31] Mapping and radiofrequency ablation of ventricular tachycardia
    Greenspon, AJ
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 2629 - 2629
  • [32] Temperature-Controlled Cooled-Tip Radiofrequency Ablation in Left Ventricular Myocardium Avoidance of Steam Pop During Ablation
    Watanabe, Ichiro
    Nuo, Min
    Okumura, Yasuo
    Ohkubo, Kimie
    Ashino, Sonoko
    Kofune, Masayoshi
    Kofune, Tatsuya
    Nakai, Toshiko
    Kasamaki, Yuji
    Hirayama, Atsushi
    INTERNATIONAL HEART JOURNAL, 2010, 51 (03) : 193 - 198
  • [33] Characterizing lesion morphology of a novel diamond-tip temperature-controlled irrigated radiofrequency ablation catheter
    Dhanjal, Tarvinder S.
    Schmidt, Megan M.
    Getman, Michael K.
    Brigham, Renee C.
    Al-Sheikhli, Jaffar
    Patchett, Ian
    Robinson, Melissa R.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (02) : 293 - 301
  • [34] Characterizing lesion morphology of a novel diamond-tip temperature-controlled irrigated radiofrequency ablation catheter
    Tarvinder S. Dhanjal
    Megan M. Schmidt
    Michael K. Getman
    Renee C. Brigham
    Jaffar Al-Sheikhli
    Ian Patchett
    Melissa R. Robinson
    Journal of Interventional Cardiac Electrophysiology, 2024, 67 : 293 - 301
  • [35] Reversible Tachycardia Mediated Cardiomyopathy after Radiofrequency Ablation of Idiopathic Left Ventricular Tachycardia
    He, Jia
    Fang, Pihua
    Liu, Zheng
    Chen, Xiongbiao
    Liu, Jun
    Tang, Min
    Jia, Yuhe
    Zhang, Shu
    CARDIOLOGY, 2014, 129 : 95 - 96
  • [36] CLOSED-LOOP TEMPERATURE-CONTROLLED RADIOFREQUENCY CATHETER ABLATION
    GILLETTE, PC
    CASE, CL
    CALKINS, HG
    CIRCULATION, 1993, 88 (04) : 165 - 165
  • [37] Reversible tachycardia mediated cardiomyopathy after radiofrequency ablation of idiopathic left ventricular tachycardia
    He, Jia
    Fang, Pi-Hua
    Liu, Zheng
    Chen, Xiong-Biao
    Liu, Jun
    Tang, Min
    Jia, Yu-He
    Zhang, Shu
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 176 (01) : E5 - E8
  • [38] What is the optimal temperature limit for temperature-controlled cooled radiofrequency ablation?
    Barold, HS
    Jain, MK
    Dixon-Tulloch, E
    Riley, R
    Wolf, PD
    Wharton, JM
    CIRCULATION, 1998, 98 (17) : 644 - 644
  • [39] Temperature-controlled radiofrequency catheter ablation of manifest accessory pathways
    Willems, S
    Chen, X
    Kottkamp, H
    Hindricks, G
    Haverkamp, W
    Rotman, B
    Shenasa, M
    Breithardt, G
    Borggrefe, M
    EUROPEAN HEART JOURNAL, 1996, 17 (03) : 445 - 452
  • [40] Temperature-Controlled Radiofrequency Ablation Using Irrigated Catheters Maximizing Ventricular Lesion Dimensions While Reducing Steam-Pop Formation
    Leshem, Eran
    Zilberman, Israel
    Barkagan, Michael
    Shapira-Daniels, Ayelet
    Sroubek, Jakub
    Govari, Assaf
    Buxton, Alfred E.
    Anter, Elad
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2020, 6 (01) : 83 - 93