Label-free electrochemical immunosensor for Ochratoxin a detection in coffee samples

被引:9
|
作者
de Oliveira, Jairo Pinto [1 ,2 ,5 ]
Burgos-Florez, Francisco [1 ,3 ]
Sampaio, Isabella [1 ]
Villalba, Pedro [4 ]
Zucolotto, Valtencir [1 ]
机构
[1] Univ Sao Paulo, Sao Carlos Inst Phys, Nanomed & Nanotoxicol Grp, CP 369, BR-13560970 Sao Carlos, SP, Brazil
[2] Univ Fed Espirito Santo, Marechal Campos 1468, BR-29040090 Vitoria, Brazil
[3] Univ Simon Bolivar, Fac Ingn, Hlth & Technol Innovat, Barranquilla 080002, Colombia
[4] Univ Norte, Dept Med, Hlth Div, Barranquilla 081007, Colombia
[5] Univ Fed Espirito Santo, Av Marechal Campos 1468, Vitoria, ES, Brazil
关键词
Ochratoxin A; Immunosensor; Label-free; Coffee; Electrochemical biosensor; PHOTOLUMINESCENCE IMMUNOSENSOR; IMPEDIMETRIC IMMUNOSENSOR; SENSITIVE DETECTION; METABOLITES; ASSAY;
D O I
10.1016/j.talanta.2023.124586
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ochratoxin A (OTA) is a nephrotoxic and carcinogenic mycotoxin frequently found in coffee, which directly impacts human health and the economy of many countries. For this reason, there has been a growing need for simple and sensitive tools for the on-site detection of this mycotoxin. In this study, we developed a label-free impedimetric immunosensor to detect OTA. The biosensor was built on a thin-film gold electrode evaporated on glass substrtes, modified with a self-assembled cysteamine monolayer and anti-OTA antibodies. Atomic force microscopy and Microspectroscopy RAMAN confirmed the successful functionalization of the electrodes. The biosensor performance was evaluated by electrochemical impedance spectroscopy and the measurements indi-cated a linear relationship between the change in the impedance values and the OTA concentration in the range from 0.5 to 100 ng mL-1 with a limit of detection of 0.15 ng mL-1. The biosensor was highly selective and did not suffer matrix interference when analyzed in coffee samples. Furthermore, considering the small sample volumes, the short time required for analysis, and the possibility of miniaturization, the developed biosensor represents a promising analytical device for on-site coffee quality analyses.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Fabrication of a label-free electrochemical immunosensor by functionalized nanofiber membrane for the ultrasensitive detection of quinalphos
    Hu, Jian-cheng
    Wen, Peng
    Wang, Yu
    Yang, Jin-yi
    Xiao, Zhi-li
    Xu, Zhen-lin
    Shen, Yu-dong
    Wang, Hong
    Hammock, Bruce D.
    FOOD CONTROL, 2024, 162
  • [42] Label-free detection of bisphenol A using a potentiometric immunosensor
    Piao, Ming-Hua
    Noh, Hui-Bog
    Rahman, Md Aminur
    Won, Mi-Sook
    Shim, Yoon-Bo
    ELECTROANALYSIS, 2008, 20 (01) : 30 - 37
  • [43] Label-Free Amperometric Immunosensor for the Detection of Carbofuran Pesticide
    Sun, Xia
    Wang, Xiangyou
    Du, Shuyuan
    Zhao, Wenping
    Li, Qingqing
    Han, Xiangbo
    SENSOR LETTERS, 2011, 9 (03) : 958 - 963
  • [44] Label-free impedimetric immunosensor for sensitive detection of atrazine
    Ionescu, Rodica E.
    Gondran, Chantal
    Bouffier, Laurent
    Jaffrezic-Renault, Nicole
    Martelet, Claude
    Cosnier, Serge
    ELECTROCHIMICA ACTA, 2010, 55 (21) : 6228 - 6232
  • [45] Label-free amperometic immunosensor for detection of brucella antibody
    Zuo, Y. (zyueming88@aliyun.com), 1600, Chinese Society of Agricultural Machinery (45):
  • [46] Porous Silicon Immunosensor for Label-free Detection of SpaA
    Jiang, Tao
    Lv, Xiaoyi
    Zhong, Furu
    Mo, Jiaqing
    Tu, Yixian
    Jia, Zhenhong
    Zhang, Fuchun
    FRONTIERS OF MANUFACTURING AND DESIGN SCIENCE, PTS 1-4, 2011, 44-47 : 2472 - +
  • [47] A Label-Free Interdigitated Microelectrodes Immunosensor for Pesticide Detection
    Marrakchi, M.
    Campos Sanchez, I.
    Helali, S.
    Mejri, N.
    Soto Camino, J.
    Gonzalez-Martinez, M. A.
    Hamdi, M.
    Abdelghani, A.
    SENSOR LETTERS, 2011, 9 (06) : 2203 - 2206
  • [48] Disposable electrochemical magneto immunosensor for simultaneous simplified calibration and determination of Ochratoxin A in coffee samples
    Jodra, Adrian
    Hervas, Mirian
    Angel Lopez, Miguel
    Escarpa, Alberto
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 221 : 777 - 783
  • [49] Label-free bead-based metallothionein electrochemical immunosensor
    Nejdl, Lukas
    Hoai Viet Nguyen
    Richtera, Lukas
    Krizkova, Sona
    Guran, Roman
    Masarik, Michal
    Hynek, David
    Heger, Zbynek
    Lundberg, Karin
    Erikson, Kristofer
    Adam, Vojtech
    Kizek, Rene
    ELECTROPHORESIS, 2015, 36 (16) : 1894 - 1904
  • [50] Impedimetric label - free immunosensor for rapid detection of Ochratoxin A in beer and wine
    Malvano, Francesca
    Albanese, Donatella
    Pilloton, Roberto
    PROCEEDINGS OF 2020 IEEE INTERNATIONAL WORKSHOP ON METROLOGY FOR AGRICULTURE AND FORESTRY (METROAGRIFOR), 2020, : 323 - 327